Numerical study on indoor environment and thermal comfort in train station waiting hall with two different air-conditioning modes

被引:17
|
作者
Zhuang, Biyao [1 ]
Shi, Juan [1 ]
Chen, Zhenqian [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ China, Nanjing 210096, Peoples R China
基金
国家重点研发计划;
关键词
radiant floor cooling; radiant wall cooling; large spaces; thermal comfort;
D O I
10.1007/s12273-020-0732-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
With the increasing size of the waiting hall, the large-area use of transparent envelope materials makes the interior surface temperature of the envelope too high, which puts forward higher requirements for the control of environment and thermal comfort indoors. In this paper, the characteristics of indoor temperature distribution, relative humidity distribution and thermal comfort under the all air system (AAs) and the radiant floor cooling and wall cooling combined with air supply system (RC/ASs) were investigated in the large spaces. The computational fluid dynamics (CFD) method was used, and the performance of the CFD model was validated by comparing the measured results with CFD simulation results in the AAs. The numerical results clearly showed that the temperature and relative humidity indoors could satisfy the design requirement both in the AAs and RC/ASs. The indoor air distribution in most areas under the RC/ASs was more uniform based on the indoor heat and humidity requirements under the cooling load of measured day. In the AAs, the total cooling capacity of air conditioning unit was the highest when indoor thermal comfort was the best, that meant that to achieve the best working condition, the air-conditioning system need high energy consumption. Meanwhile, the RC/ASs addressed the problem that the temperature around the seated passengers in the waiting area was relatively high in the AAs. This paper will provide reference for the air conditioning system design in the similar large spaces in the future.
引用
收藏
页码:337 / 349
页数:13
相关论文
共 50 条
  • [31] Investigating the Applicability of Different Thermal Comfort Models in Kuwait Classrooms Operated in Hybrid Air-Conditioning Mode
    Al-Rashidi, Khaled E.
    Loveday, Dennis L.
    Al-Mutawa, Nawaf K.
    SUSTAINABILITY IN ENERGY AND BUILDINGS, 2009, : 347 - +
  • [33] NUMERICAL SIMULATION ON AIR DISTRIBUTION OF A TENNIS HALL IN WINTER AND EVALUATION ON INDOOR THERMAL ENVIRONMENT
    Sui, X.
    Han, G.
    Chen, F.
    ENGINEERING REVIEW, 2014, 34 (02) : 109 - 118
  • [34] Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System
    Subramaniam, Konguvel Rajeswari
    Cheng, Chi-Tsun
    Pang, Toh Yen
    SENSORS, 2023, 23 (03)
  • [35] Review of the advances and applications of variable refrigerant flow heating, ventilating, and air-conditioning systems for improving indoor thermal comfort and air quality
    Napoleon Enteria
    Odinah Cuartero-Enteria
    Takao Sawachi
    International Journal of Energy and Environmental Engineering, 2020, 11 : 459 - 483
  • [36] Review of the advances and applications of variable refrigerant flow heating, ventilating, and air-conditioning systems for improving indoor thermal comfort and air quality
    Enteria, Napoleon
    Cuartero-Enteria, Odinah
    Sawachi, Takao
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (04) : 459 - 483
  • [37] Numerical study of Indoor Air Quality and thermal comfort under stratum ventilation
    Tian, Lin
    Lin, Zhang
    Liu, Jing
    Wang, Qiuwang
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2008, 8 (7-8): : 541 - 548
  • [38] Study on indoor thermal environment in integrated facade system: Sun shading effect of louver and case study of annual air-conditioning load
    Sato, Tomoyuki
    Kubo, Kentaro
    Hikone, Shigeru
    Misawa, Yutaka
    Cho, Wanghee
    Iwamoto, Shizuo
    Iwata, Mamoru
    Journal of Environmental Engineering, 2012, 77 (676) : 467 - 474
  • [39] CFD study of the thermal environment in an air-conditioned train station building
    Li, Qiong
    Yoshino, Hiroshi
    Mochida, Akashi
    Lei, Bo
    Meng, Qinglin
    Zhao, Lihua
    Lun, Yufat
    BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1452 - 1465
  • [40] Effect of different building envelope materials on thermal comfort and air-conditioning energy savings: A case study in Basra city, Iraq
    Homod, Raad Z.
    Almusaed, Amjad
    Almssad, Asaad
    Jaafar, Manar K.
    Goodarzi, Marjan
    Sahari, Khairul S. M.
    JOURNAL OF ENERGY STORAGE, 2021, 34