Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System

被引:5
|
作者
Subramaniam, Konguvel Rajeswari [1 ]
Cheng, Chi-Tsun [1 ]
Pang, Toh Yen [1 ]
机构
[1] RMIT Univ, STEM Coll, Sch Engn, 124 Trobe St, Melbourne, Vic 3000, Australia
关键词
heating; ventilation; air-conditioning system; thermal comfort; predicted mean vote; indoor air quality; carbon dioxide; fuzzy logic control; MANAGEMENT;
D O I
10.3390/s23031395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conventional heating ventilation and air-conditioning (HVAC) controllers have been designed to mainly control the temperature of a confined compartment, such as a room or a cabin of a vehicle. Other important parameters related to the thermal comfort and indoor air quality (IAQ) of the confined compartment have often been ignored. In this project, IAQ in the vehicle cabin was represented by its carbon dioxide (CO2) concentration, and the occupants' thermal comfort levels were estimated with the predicted mean vote (PMV) index. A new fuzzy logic controller (FLC) was designed and developed using the MATLAB fuzzy logic toolbox and Simulink to provide a nonlinear mapping between the measured values, i.e., PMV, temperature, CO2, and control parameters (recirculation flaps, blower's speed, and refrigerant mass flow rate) of a vehicle HVAC system. The new FLC aimed to regulate both in-cabin PMV and CO2 values without significantly increasing overall energy consumption. To evaluate the effectiveness of the proposed FLC, a cabin simulator was used to mimic the effects of different HVAC variables and indoor/outdoor environmental settings, which represented the in-cabin PMV and IAQ readings. Results demonstrated that the new FLC was effective in regulating the in-cabin PMV level and CO2 concentration, at desirable levels, by adaptively controlling the opening and closing of the recirculation flap based on in-cabin temperature and CO2 readings, while maintaining an average-to-good energy consumption level. The proposed FLC could be applied to a large variety of HVAC systems by utilizing low-cost sensors, without the need to significantly modify the internal design of the HVAC system.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Effect of ventilation patterns on indoor thermal comfort and air-conditioning cooling and heating load using simulation
    Dian Sekartaji
    Yuji Ryu
    Didit Novianto
    [J]. City and Built Environment , 1 (1):
  • [2] Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics
    Sekhar, SC
    Ching, CS
    [J]. ENERGY AND BUILDINGS, 2002, 34 (05) : 431 - 444
  • [3] Estimation of the air quality of a vehicle interior: The effect of the ratio of fresh air to recirculated air from a heating, ventilation and air-conditioning system
    Seo, Jinwon
    Choi, Yunho
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2013, 227 (08) : 1162 - 1172
  • [4] Thermal comfort and energy saving in a vehicle compartment using a localized air-conditioning system
    Oh, Myoung Su
    Ahn, Jae Hwan
    Kim, Dong Woo
    Fang, Dong Soo
    Kim, Yongchan
    [J]. APPLIED ENERGY, 2014, 133 : 14 - 21
  • [5] Analysis of Indoor Thermal Comfort of Different Air-conditioning Systems
    Zhao, Jianhui
    Xu, Hongyi
    Wu, Yehao
    Lei, Chao
    [J]. 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2021, 647
  • [6] Simulation of city heating and air-conditioning system
    Sui, J
    Li, NC
    Jiang, Y
    Liu, SQ
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 697 - 702
  • [7] Review of the advances and applications of variable refrigerant flow heating, ventilating, and air-conditioning systems for improving indoor thermal comfort and air quality
    Napoleon Enteria
    Odinah Cuartero-Enteria
    Takao Sawachi
    [J]. International Journal of Energy and Environmental Engineering, 2020, 11 : 459 - 483
  • [8] Review of the advances and applications of variable refrigerant flow heating, ventilating, and air-conditioning systems for improving indoor thermal comfort and air quality
    Enteria, Napoleon
    Cuartero-Enteria, Odinah
    Sawachi, Takao
    [J]. INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (04) : 459 - 483
  • [9] Simulation and Optimization of Indoor Thermal Environment in a Ship Air-conditioning System
    Liu Hongmin
    [J]. 2011 2ND INTERNATIONAL CONFERENCE ON CHALLENGES IN ENVIRONMENTAL SCIENCE AND COMPUTER ENGINEERING (CESCE 2011), VOL 11, PT C, 2011, 11 : 1055 - 1063
  • [10] Development of an indoor environment evaluation model for heating, ventilation and air-conditioning control system of office buildings in subtropical region considering indoor health and thermal comfort
    Huang, Miaohong
    Liao, Yundan
    [J]. INDOOR AND BUILT ENVIRONMENT, 2022, 31 (03) : 807 - 819