Fuzzy Logic Controlled Simulation in Regulating Thermal Comfort and Indoor Air Quality Using a Vehicle Heating, Ventilation, and Air-Conditioning System

被引:5
|
作者
Subramaniam, Konguvel Rajeswari [1 ]
Cheng, Chi-Tsun [1 ]
Pang, Toh Yen [1 ]
机构
[1] RMIT Univ, STEM Coll, Sch Engn, 124 Trobe St, Melbourne, Vic 3000, Australia
关键词
heating; ventilation; air-conditioning system; thermal comfort; predicted mean vote; indoor air quality; carbon dioxide; fuzzy logic control; MANAGEMENT;
D O I
10.3390/s23031395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conventional heating ventilation and air-conditioning (HVAC) controllers have been designed to mainly control the temperature of a confined compartment, such as a room or a cabin of a vehicle. Other important parameters related to the thermal comfort and indoor air quality (IAQ) of the confined compartment have often been ignored. In this project, IAQ in the vehicle cabin was represented by its carbon dioxide (CO2) concentration, and the occupants' thermal comfort levels were estimated with the predicted mean vote (PMV) index. A new fuzzy logic controller (FLC) was designed and developed using the MATLAB fuzzy logic toolbox and Simulink to provide a nonlinear mapping between the measured values, i.e., PMV, temperature, CO2, and control parameters (recirculation flaps, blower's speed, and refrigerant mass flow rate) of a vehicle HVAC system. The new FLC aimed to regulate both in-cabin PMV and CO2 values without significantly increasing overall energy consumption. To evaluate the effectiveness of the proposed FLC, a cabin simulator was used to mimic the effects of different HVAC variables and indoor/outdoor environmental settings, which represented the in-cabin PMV and IAQ readings. Results demonstrated that the new FLC was effective in regulating the in-cabin PMV level and CO2 concentration, at desirable levels, by adaptively controlling the opening and closing of the recirculation flap based on in-cabin temperature and CO2 readings, while maintaining an average-to-good energy consumption level. The proposed FLC could be applied to a large variety of HVAC systems by utilizing low-cost sensors, without the need to significantly modify the internal design of the HVAC system.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Influence of Urban Microclimate on Air-Conditioning Energy Needs and Indoor Thermal Comfort in Houses
    Liao, Feng-Chi
    Cheng, Ming-Jen
    Hwang, Ruey-Lung
    [J]. ADVANCES IN METEOROLOGY, 2015, 2015
  • [32] Influence of water contamination in air-conditioning system on indoor air quality and proviting measures
    Zheng, AP
    [J]. ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 220 - 225
  • [33] Influence of indoor temperature and humidity on thermal comfort and energy consumption of air-conditioning systems
    Zhang, Jing-Ling
    Wan, Jian-Wu
    [J]. Chongqing Jianzhu Daxue Xuebao/Journal of Chongqing Jianzhu University, 2008, 30 (01): : 9 - 12
  • [34] A review of integrated radiant heating/cooling with ventilation systems- Thermal comfort and indoor air quality
    Zhang, Chen
    Pomianowski, Michal
    Heiselberg, Per Kvols
    Yu, Tao
    [J]. ENERGY AND BUILDINGS, 2020, 223
  • [35] Vocal Ergonomics in the Workplace: Heating, Ventilation, and Air-Conditioning Method Influences on Vocal Comfort and Function
    Sandage, Mary J.
    Rahn, Keith A.
    Smith, Audrey G.
    [J]. JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2017, 60 (02): : 355 - 363
  • [36] Numerical and experimental investigation on the air flow characteristics of heating, ventilation, and air-conditioning module for a small electric vehicle
    Li, Kang
    Gao, Hao
    Jia, Peng
    Su, Lin
    Fang, Yidong
    Zhang, Hua
    Liu, Ni
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2020, 234 (06) : 1597 - 1609
  • [37] SIMULATION OF A LOW CAPACITY ABSORPTION COOLING SYSTEM FOR INDOOR AIR-CONDITIONING
    Evola, Gianpiero
    Le Pierres, Nolwenn
    Marletta, Luigi
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2015, 33 (04) : 203 - 210
  • [38] On the indoor air quality, thermal comfort of occupants and energy conservation of air conditioning of an apartment unit
    Liu, OZ
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1045 - 1051
  • [39] Heat Index Estimation of Ventilating Air-Conditioning Heating Area Considering Thermal Comfort
    Luo, Zhibin
    [J]. INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2022, 40 (02) : 468 - 474
  • [40] Thermal Comfort and Indoor Air Quality of Task Ambient Air Conditioning in Modern Office Buildings
    Zheng, Guozhong
    Jing, Youyin
    Huang, Hongxia
    Ma, Puzhao
    [J]. 2009 INTERNATIONAL CONFERENCE ON INFORMATION MANAGEMENT, INNOVATION MANAGEMENT AND INDUSTRIAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, : 533 - +