Free-breathing dynamic liver examination using a radial 3D T1-weighted gradient echo sequence with moderate undersampling for patients with limited breath-holding capacity

被引:20
|
作者
Kaltenbach, Benjamin [1 ]
Roman, Andrei [1 ]
Polkowski, Christoph [1 ]
Gruber-Rouh, Tatjana [1 ]
Bauer, Ralf W. [1 ,2 ]
Hammerstingl, Renate [1 ]
Vogl, Thomas J. [1 ]
Zangos, Stephan [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[2] Kantonsspital, Div Radiol & Nucl Med, St Gallen, Switzerland
关键词
Dynamic liver MRI; Respiratory artifacts; Radial data sampling; Undersampled radial acquisition; MRI; RECONSTRUCTION; ARTIFACTS; QUALITY;
D O I
10.1016/j.ejrad.2016.11.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare free-breathing radial VIBE with moderate undersampling (us-radial-VIBE) with a standard breathhold TI-weighted volumetric interpolated sequence (3D GRE VIBE) in patients unable to suspend respiration during dynamic liver examination. Material and methods: 23 consecutive patients underwent dynamic liver MR examination using the free breathing us-radial-VIBE sequence as part of their oncologic follow-up. All patients were eligible for the free-breathing protocol due to severe respiratory artifacts at the planning or precontrast sequences. The us-radial-VIBE acquisitions were compared to the patients1 last staging liver MRI including a standard breathhold 3D GRE VIBE. For an objective image evaluation, signal intensity (SI), image noise (IN), signal-to-noise ratio (SNR) and contrast-enhancement ratio (CER) were compared. Representative image quality parameters, including typical artifacts were independently, retrospectively and blindly scored by four readers. Results: Us-radial-VIBE had significant lower SNR (p < 0.0001) and higher IN (p < 0.0001), whereas SI did not differ (p = 0.62). Temporal resolution assessed with CER in the arterial phase showed higher values for us-radial-VIBE (p = 0.028). Subjective image quality parameters received generally slightly higher scores for 3D GRE VIBE. In a smaller subgroup comprising patients with severe respiratory artifacts also at reference breathhold 3D GRE VIBE examination, us-radial-VIBE showed significantly higher image quality scores. Furthermore, there were generally more severe respiratory artifacts in 3D GRE VIBE, whereas streaking was characteristic in almost all us-radial-VIBE acquisitions but did not affect diagnostic validity. Conclusion: Free-breathing dynamic liver imaging using us-radial-VIBE delivers accurate temporal resolution, low motion artifact susceptibility and good image quality and represents a promising alternative in patients unable to suspend respiration. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [21] Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    Kyung Won Kim
    Jeong Min Lee
    Yong Sik Jeon
    Sung Eun Kang
    Jee Hyun Baek
    Joon Koo Han
    Byung Ihn Choi
    Yung-Jue Bang
    Berthold Kiefer
    Kai Tobias Block
    Hyunjun Ji
    Simon Bauer
    Chin Kim
    European Radiology, 2013, 23 : 1352 - 1360
  • [22] MR venography: True FISP sequence versus Gadolinium-enhanced 3d T1-weighted gradient-echo sequence
    Pedrosa, I
    Yu, J
    Mahallati, H
    Bryer, HP
    Morrin, MM
    Rofsky, NM
    RADIOLOGY, 2002, 225 : 359 - 360
  • [23] Performance of free-breathing dynamic T1-weighted sequences in patients at risk of developing motion artifacts undergoing gadoxetic acid–enhanced liver MRI
    So Hyun Park
    Jeong Hee Yoon
    Jin Young Park
    Young Sup Shim
    Sang Min Lee
    Seung Joon Choi
    Marcel Dominik Nickel
    Jeong Min Lee
    European Radiology, 2023, 33 : 4378 - 4388
  • [24] Respiratory Navigated Free Breathing 3D Spoiled Gradient-Recalled Echo Sequence for Contrast-Enhanced Examination of the Liver: Diagnostic Utility and Comparison With Free Breathing and Breath-Hold Conventional Examinations
    Young, Phillip M.
    Brau, Anja C.
    Iwadate, Yuji
    Vasanawala, Shreyas
    Daniel, Bruce L.
    Tamrazi, Anobel
    Herfkens, Robert J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 687 - 691
  • [25] Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of Workflow and Diagnostic Quality
    Glandorf, Julian
    Horstmann, Dominik
    Duex, Daniel Markus
    Wacker, Frank
    Gutberlet, Marcel
    Hensen, Bennet
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 46 (02) : 274 - 279
  • [26] Performance of free-breathing dynamic T1-weighted sequences in patients at risk of developing motion artifacts undergoing gadoxetic acid-enhanced liver MRI
    Park, So Hyun
    Yoon, Jeong Hee
    Park, Jin Young
    Shim, Young Sup
    Lee, Sang Min
    Choi, Seung Joon
    Nickel, Marcel Dominik
    Lee, Jeong Min
    EUROPEAN RADIOLOGY, 2023, 33 (06) : 4378 - 4388
  • [27] Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of Workflow and Diagnostic Quality
    Julian Glandorf
    Dominik Horstmann
    Daniel Markus Düx
    Frank Wacker
    Marcel Gutberlet
    Bennet Hensen
    CardioVascular and Interventional Radiology, 2023, 46 : 274 - 279
  • [28] Knee osteochondral junction imaging using a fast 3D T1-weighted ultrashort echo time cones sequence at 3T
    Cai, Zhenyu
    Wei, Zhao
    Wu, Mei
    Jerban, Saeed
    Jang, Hyungseok
    Li, Shaolin
    Yuan, Xuchun
    Ma, Ya-Jun
    MAGNETIC RESONANCE IMAGING, 2020, 73 : 76 - 83
  • [29] Contrast-Enhanced Radial 3D Fat-Suppressed T1-Weighted Gradient-Recalled Echo Sequence Versus Conventional Fat-Suppressed Contrast-Enhanced T1-Weighted Studies of the Head and Neck
    Wu, Xin
    Raz, Eytan
    Block, Tobias K.
    Geppert, Christian
    Hagiwara, Mari
    Bruno, Mary T.
    Fatterpekar, Girish M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 883 - 889
  • [30] A 3D T1-WEIGHTED GRADIENT-ECHO SEQUENCE FOR ROUTINE USE IN 3D RADIOSURGICAL TREATMENT PLANNING OF BRAIN METASTASES - FIRST CLINICAL-RESULTS
    HAWIGHORST, H
    SCHAD, LR
    GADEMANN, G
    BLUML, S
    KNOPP, MV
    WENZ, F
    VANKAICK, G
    EUROPEAN RADIOLOGY, 1995, 5 (01) : 19 - 25