Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of Workflow and Diagnostic Quality

被引:2
|
作者
Glandorf, Julian [1 ]
Horstmann, Dominik [1 ]
Duex, Daniel Markus [1 ]
Wacker, Frank [1 ]
Gutberlet, Marcel [1 ]
Hensen, Bennet [1 ]
机构
[1] Hannover Med Sch, Inst Diag & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
MR-guidance; IMRI; Percutaneous liver interventions; StarVIBE; Stack-of-stars; Free-breathing imaging;
D O I
10.1007/s00270-022-03350-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:To evaluate workflow efficiency and diagnostic quality of a free-breathing 3D stack-of-stars gradient echo (Radial GRE) sequence compared to a breath-hold 3D Cartesian gradient echo (Cartesian GRE) sequence for needle position control in MR-guided liver interventions. Materials and Methods:12 MR-guided liver interventions were performed on a 1.5 T Siemens Aera and analyzed retrospectively. 15 series of the Radial GRE sequence were compared to 14 series of the Cartesian GRE sequence regarding the time interval between two consecutive live-scans for needle tracking (Tracking-2-Tracking-Time). The quality of both sequences was compared by the SNR within comparable slices in liver and tumor ROIs. The CNR was calculated by subtraction of the SNR values. Subjective image quality scores of three radiologists were assessed and inter-rater reliability was tested by Fleiss' kappa. Values are given as mean & PLUSMN; SD. P-values < 0.05 were considered as significant. Results:The median Tracking-2-Tracking-Time was significantly shorter for the Radial GRE sequence, 185 +/- 42 s vs. 212 +/- 142 s (p = 0.04) and the median SNR of the liver and tumor ROIs were significantly higher in the Radial GRE sequence, 249 +/- 92 vs. 109 +/- 67 (p = 0.03) and 165 +/- 74 vs. 77 +/- 43 (p = 0.02). CNR between tumor and liver ROIs showed a tendency to be higher for the Radial GRE sequence without significance, 68 +/- 48 vs. 49 +/- 32 (p = 0.28). Mean subjective image quality was 3.33 +/- 1.08 vs. 2.62 +/- 0.95 comparing Radial and Cartesian GRE with a Fleiss' kappa of 0.39 representing fair inter-rater reliability. Conclusion:A free-breathing 3D stack-of-stars gradient echo sequence can simplify the workflow and reduce intervention time, while providing superior image quality. Under local anesthesia, it increases patient comfort and reduces potential risks for needle dislocations in MR-guided liver interventions by avoiding respiratory arrests for needle position control.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 50 条
  • [1] Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of Workflow and Diagnostic Quality
    Julian Glandorf
    Dominik Horstmann
    Daniel Markus Düx
    Frank Wacker
    Marcel Gutberlet
    Bennet Hensen
    CardioVascular and Interventional Radiology, 2023, 46 : 274 - 279
  • [2] Motion-Compensated Free-Breathing 3D MRI for MR Simulation Using Rotating Stack-Of-Stars Acquisition
    Zhou, Z.
    Han, F.
    Gao, Y.
    Cao, M.
    Steinberg, M.
    Lee, P.
    Raldow, A.
    Low, D.
    Yang, Y.
    Hu, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 3049 - 3049
  • [3] Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence
    Xu, Pengfei
    Zhang, Jichang
    Nan, Zhen
    Meersmann, Thomas
    Wang, Chengbo
    SENSORS, 2022, 22 (09)
  • [4] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Duffy, Patrick B.
    Stemmer, Alto
    Callahan, Michael J.
    Cravero, Joseph P.
    Johnston, Patrick R.
    Warfield, Simon K.
    Bixby, Sarah D.
    PEDIATRIC RADIOLOGY, 2021, 51 (09) : 1645 - 1653
  • [5] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Patrick B. Duffy
    Alto Stemmer
    Michael J. Callahan
    Joseph P. Cravero
    Patrick R. Johnston
    Simon K. Warfield
    Sarah D. Bixby
    Pediatric Radiology, 2021, 51 : 1645 - 1653
  • [6] Free-breathing liver fat quantification using a multiecho 3D stack-of-radial technique
    Armstrong, Tess
    Dregely, Isabel
    Stemmer, Alto
    Han, Fei
    Natsuaki, Yutaka
    Sung, Kyunghyun
    Wu, Holden H.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 370 - 382
  • [7] Free-breathing fat and R2* quantification in the liver using a stack-of-stars multi-echo acquisition with respiratory-resolved model-based reconstruction
    Schneider, Manuel
    Benkert, Thomas
    Solomon, Eddy
    Nickel, Dominik
    Fenchel, Matthias
    Kiefer, Berthold
    Maier, Andreas
    Chandarana, Hersh
    Block, Kai Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2592 - 2605
  • [8] Comparison of diagnostic quality of 3D ultrashort-echo-time techniques for pulmonary magnetic resonance imaging in free-breathing
    Metz, Corona
    Weng, Andreas Max
    Boeckle, David
    Heidenreich, Julius Frederik
    Slawig, Anne
    Benkert, Thomas
    Kraus, Sabrina
    Koestler, Herbert
    Veldhoen, Simon
    ACTA RADIOLOGICA, 2023, 64 (05) : 1851 - 1858
  • [9] Free-breathing 3D Stack of Stars GRE (StarVIBE) sequence for detecting pulmonary nodules in 18F-FDG PET/MRI
    Bruckmann, Nils Martin
    Kirchner, Julian
    Morawitz, Janna
    Umutlu, Lale
    Fendler, Wolfgang P.
    Herrmann, Ken
    Bittner, Ann-Kathrin
    Hoffmann, Oliver
    Fehm, Tanja
    Lindemann, Maike E.
    Buchbender, Christian
    Antoch, Gerald
    Sawicki, Lino M.
    EJNMMI PHYSICS, 2022, 9 (01)
  • [10] Free-breathing 3D Stack of Stars GRE (StarVIBE) sequence for detecting pulmonary nodules in 18F-FDG PET/MRI
    Nils Martin Bruckmann
    Julian Kirchner
    Janna Morawitz
    Lale Umutlu
    Wolfgang P. Fendler
    Ken Herrmann
    Ann-Kathrin Bittner
    Oliver Hoffmann
    Tanja Fehm
    Maike E. Lindemann
    Christian Buchbender
    Gerald Antoch
    Lino M. Sawicki
    EJNMMI Physics, 9