Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthalmoscopy in the Diagnostic Innovations in Glaucoma Study

被引:7
|
作者
Ng, Diana [1 ]
Zangwill, Linda M. [1 ]
Racette, Lyne [1 ]
Bowd, Christopher [1 ]
Pascual, John P. [1 ]
Bourne, Rupert R. A. [1 ]
Boden, Catherine [1 ]
Weinreb, Robert N. [1 ]
Sample, Pamela A. [1 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
关键词
D O I
10.1016/j.ajo.2006.04.027
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To assess agreement between structural and functional testing in classifying eyes as normal or abnormal and their repeatability on two consecutive visits by means of standard automated perimetry (SAP) and confocal scanning laser ophthalmoscopy. center dot DESIGN: Analysis of selected data obtained from a prospective longitudinal observational cohort study, the Diagnostic Innovations in Glaucoma Study. center dot METHODS: One hundred fifty,one participants with a SAP and a Heidelberg Retina Tomograph (HRT) test within a three,month window at two visits within 15 months were included. Eyes were classified by SAP and HRT at each visit. Agreement and repeatability were assessed by kappa statistics. center dot RESULTS: At visit 1, 33 (22%) of 151 eyes had only SAP defects, 11 (7%) eyes had only HRT defects, and 35 (23%) eyes had both SAP and HRT defects. Seventy-two eyes (48%) were classified as normal by both tests. Similar results were obtained for visit 2. The agreement between SAP and HRT in classifying eyes was 70% (kappa = 0.393) at visit one and 68% (kappa = 0.363) at visit 2. Repeatability of classification by SAP alone, HRT alone, and both SAP and HRT between visits 1 and 2 was 84% (kappa = 0.693), 89% (kappa = 0.752), and 90% (kappa = 0.723), respectively. center dot CONCLUSIONS: Agreement between SAP and HRT was only fair at both visits. Repeatability across visits was substantial for SAP alone, HRT alone, and for the combination of SAP and HRT. These results suggest that detection of particular features of glaucomatous damage depends on the technique used. Structural and functional tests appear complementary, and both should be used for early detection of glaucoma.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [21] Comparison of Saccadic Vector Optokinetic Perimetry and Standard Automated Perimetry in Glaucoma. Part I: Threshold Values and Repeatability
    Murray, Ian C.
    Perperidis, Antonios
    Cameron, Lorraine A.
    McTrusty, Alice D.
    Brash, Harry M.
    Tatham, Andrew J.
    Agarwal, Pankaj K.
    Fleck, Brian W.
    Minns, Robert A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (05):
  • [22] The effect of compression on clinical diagnosis of glaucoma based on nonanalyzed confocal scanning laser ophthalmoscopy images
    Abràmoff, MD
    OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (03): : 263 - 263
  • [23] The incidence of visual field defects at each of 52 locations in standard automated perimetry in glaucomatous eyes - Data from the diagnostic innovations in glaucoma study (DIGS)
    Hu, A
    Pascual, JP
    Weinreb, RN
    Sample, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [24] Diagnostic laser in glaucoma:: scanning laser polarimetry (GDx VCC) and confocal scanning laser tomography (HRT)
    Renard, JP
    Giraud, JM
    May, F
    Rigal-Sastourné, JC
    Oubaaz, A
    Reda, K
    Maurin, JF
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (02): : 177 - 184
  • [25] A pilot study to detect glaucoma with confocal scanning laser ophthalmoscopy compared with nonmydriatic stereoscopic photography in a community health screening
    Ohkubo, Shinji
    Takeda, Hisashi
    Higashide, Tomomi
    Sasaki, Tsugihisa
    Sugiyama, Kazuhisa
    JOURNAL OF GLAUCOMA, 2007, 16 (06) : 531 - 538
  • [26] An Automated Approach for Localizing Retinal Blood Vessels in Confocal Scanning Laser Ophthalmoscopy Fundus Images
    Kromer, Robert
    Shafin, Rahman
    Boelefahr, Sebastian
    Klemm, Maren
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (04) : 485 - 494
  • [27] An Automated Approach for Localizing Retinal Blood Vessels in Confocal Scanning Laser Ophthalmoscopy Fundus Images
    Robert Kromer
    Rahman Shafin
    Sebastian Boelefahr
    Maren Klemm
    Journal of Medical and Biological Engineering, 2016, 36 : 485 - 494
  • [28] Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage
    Kanamori, A
    Nagai-Kusuhara, A
    Escaño, MFT
    Maeda, H
    Nakamura, M
    Negi, A
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (01) : 58 - 68
  • [29] Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage
    Akiyasu Kanamori
    Azusa Nagai-Kusuhara
    Michael F. T. Escaño
    Hidetaka Maeda
    Makoto Nakamura
    Akira Negi
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 58 - 68
  • [30] Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients
    Fanihagh, Farsad
    Kremmer, Stephan
    Anastassiou, Gerasimos
    Schallenberg, Maurice
    Steuhl, Klaus-Peter
    Selbach, Michael
    OPEN OPHTHALMOLOGY JOURNAL, 2015, 9 : 41 - 48