On the performance of a baffled glazed-bladed entrance solar air heater

被引:34
|
作者
Kabeel, A. E. [1 ]
Hamed, Mofreh. H. [2 ,3 ]
Omara, Z. M. [2 ]
Kandel, A. W. [2 ]
机构
[1] Tanta Univ, Fac Engn, Tanta, Egypt
[2] Kafrelsheikh Univ, Fac Engn, Kafr Al Sheikh, Egypt
[3] Higher Inst Engn & Technol, Kafrelsheikh, Egypt
关键词
Solar air heater; Entrance region; Baffles; Guide blades; Thermal efficiency; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; ABSORBER PLATE; FLAT-PLATE; FRICTION FACTOR; FLUID-FLOW; THERMOHYDRAULIC PERFORMANCE; TRANSFER AUGMENTATION; LONGITUDINAL FINS; ENERGY-STORAGE;
D O I
10.1016/j.applthermaleng.2018.04.141
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a baffled glazed-bladed entrance air heater (BGBSAH) was experimentally investigated and compared with a conventional one at the same operating conditions. The solar air heater was modified at the entrance region. This region was covered with a glass coverinstead of a steel one to increase the heating area exposed to solar radiation (I-R). In addition, the entrance region was boosted by guide blades to affirm a good air distribution inside the heater. Baffles attached to nineteen longitudinal fins were fixed inside the heater. These baffles were used to increase the heat transfer area, the length of air flow path, and the heat capacity of SAH via increasing the mass of the material. Three various numbers of baffles (170, 410 and 800) were used. Moreover, four values of air flow rates ranged from 0.013 to 0.04 kg/s were investigated. The results showed that, at the same mass flow rate, the performance of SAH was directly proportional to the baffles number. In addition, the results revealed that the maximum daily temperature difference obtained from the BGBSAH with 800 baffles was 51.9 degrees C compared to 22.7 degrees C for the conventional one at 0.013 kg/s. Besides, the daily efficiency was improved by 29.91-51.69% in case of BGBSAH with 800 baffles compared to the conventional one. For conventional SAH the average cost per kW is 0.0146 $ while for BGBSAH are 0.00733, 0.00787 and 0.0084 $ for 800, 410 and 170 baffles, respectively.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [41] Design and thermal performance evaluation of a novel solar air heater
    Saxena, Abhishek
    Srivastava, Ghanshyam
    Tirth, Vineet
    RENEWABLE ENERGY, 2015, 77 : 501 - 511
  • [42] Performance evaluation of a smooth flat plate solar air heater
    Kumar, Thakur Sanjay
    Mittal, Vijay
    Thakur, N. S.
    Kumar, Anoop
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2009, 23 (1-2): : 105 - 117
  • [43] Performance evaluation of a smooth flat plate solar air heater
    Mittal, Vijay
    Kumar, Thakur Sanjay
    Thakur, N.S.
    Kumar, Anoop
    Energy Education Science and Technology Part A: Energy Science and Research, 2009, 23 (02): : 105 - 117
  • [44] Thermal performance evaluation of a solar air heater with rotating turbulators
    Singh, Sarvapriya
    Mitra, Santanu
    Kumar, Manish
    Suman, Siddharth
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48
  • [45] Evaluation of Solar Dryer/Air Heater Performance and the Accuracy of the Result
    Srivastava, A. K.
    Shukla, S. K.
    Mishra, Sandeep
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2360 - 2369
  • [46] A mathematical model of thermal performance of a solar air heater with slats
    Ammari, HD
    RENEWABLE ENERGY, 2003, 28 (10) : 1597 - 1615
  • [47] THEORY OF BAFFLED SOLAR AIR HEATERS
    YEH, HM
    ENERGY, 1992, 17 (07) : 697 - 702
  • [48] Investigation of the thermohydraulic performance of impinging jet solar air heater
    Chauhan, Ranchan
    Thakur, N. S.
    ENERGY, 2014, 68 : 255 - 261
  • [49] Development of an empirical model for assessment of solar air heater performance
    Choudhury, P.K.
    Baruah, D.C.
    Choudhury, P.K., 1600, Bellwether Publishing, Ltd. (29): : 56 - 75
  • [50] Performance enhancement of a curved solar air heater using CFD
    Singh, Ajeet Pratap
    Singh, O. P.
    SOLAR ENERGY, 2018, 174 : 556 - 569