On the performance of a baffled glazed-bladed entrance solar air heater

被引:34
|
作者
Kabeel, A. E. [1 ]
Hamed, Mofreh. H. [2 ,3 ]
Omara, Z. M. [2 ]
Kandel, A. W. [2 ]
机构
[1] Tanta Univ, Fac Engn, Tanta, Egypt
[2] Kafrelsheikh Univ, Fac Engn, Kafr Al Sheikh, Egypt
[3] Higher Inst Engn & Technol, Kafrelsheikh, Egypt
关键词
Solar air heater; Entrance region; Baffles; Guide blades; Thermal efficiency; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; ABSORBER PLATE; FLAT-PLATE; FRICTION FACTOR; FLUID-FLOW; THERMOHYDRAULIC PERFORMANCE; TRANSFER AUGMENTATION; LONGITUDINAL FINS; ENERGY-STORAGE;
D O I
10.1016/j.applthermaleng.2018.04.141
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a baffled glazed-bladed entrance air heater (BGBSAH) was experimentally investigated and compared with a conventional one at the same operating conditions. The solar air heater was modified at the entrance region. This region was covered with a glass coverinstead of a steel one to increase the heating area exposed to solar radiation (I-R). In addition, the entrance region was boosted by guide blades to affirm a good air distribution inside the heater. Baffles attached to nineteen longitudinal fins were fixed inside the heater. These baffles were used to increase the heat transfer area, the length of air flow path, and the heat capacity of SAH via increasing the mass of the material. Three various numbers of baffles (170, 410 and 800) were used. Moreover, four values of air flow rates ranged from 0.013 to 0.04 kg/s were investigated. The results showed that, at the same mass flow rate, the performance of SAH was directly proportional to the baffles number. In addition, the results revealed that the maximum daily temperature difference obtained from the BGBSAH with 800 baffles was 51.9 degrees C compared to 22.7 degrees C for the conventional one at 0.013 kg/s. Besides, the daily efficiency was improved by 29.91-51.69% in case of BGBSAH with 800 baffles compared to the conventional one. For conventional SAH the average cost per kW is 0.0146 $ while for BGBSAH are 0.00733, 0.00787 and 0.0084 $ for 800, 410 and 170 baffles, respectively.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [21] Thermal Performance of Solar Air Heater with Porous Material
    Teeboonma, U.
    Boonthum, E.
    JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 2019, : 723 - 733
  • [22] PERFORMANCE PREDICTION OF A CORRUGATED COVER SOLAR AIR HEATER
    CHOUDHURY, C
    GARG, HP
    ENERGY CONVERSION AND MANAGEMENT, 1991, 32 (02) : 115 - 122
  • [23] DESIGN AND THERMAL PERFORMANCE OF A MATRIX SOLAR AIR HEATER
    BHARADWAJ, SS
    SINGH, D
    BANSAL, NK
    ENERGY CONVERSION AND MANAGEMENT, 1981, 21 (04) : 253 - 256
  • [24] Thermal performance of packed bed solar air heater
    Tiwari, Prashant
    Kumar, Arvind
    Sarviya, R. M.
    2013 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), 2013,
  • [25] Experimental study on the performance of spiral solar air heater
    Jia, Binguang
    Liu, Fang
    Wang, Da
    SOLAR ENERGY, 2019, 182 : 16 - 21
  • [26] A review of the performance of double pass solar air heater
    Chamoli, Sunil
    Chauhan, Ranchan
    Thakur, N. S.
    Saini, J. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01): : 481 - 492
  • [27] DESIGN AND PERFORMANCE OF A ROOF INTEGRATED SOLAR AIR HEATER
    PECK, MK
    PROCTOR, D
    SOLAR ENERGY, 1983, 31 (02) : 183 - 189
  • [28] Performance Evaluation of Solar Crop Dryer Integrated with Solar Air Heater
    Varun
    2011 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON POWER AND ENERGY SYSTEMS: ISSUES & PROSPECTS FOR ASIA (ICUE), 2011,
  • [29] Comparative study based on energy and exergy analyses of a baffled solar air heater with latent storage collector
    Ghiami, Amir
    Ghiami, Shamsoddin
    APPLIED THERMAL ENGINEERING, 2018, 133 : 797 - 808
  • [30] Simulation on the heat performance of a novel glazed transpired solar air collector
    Zhang, H. (zhhuan@tju.edu.cn), 1600, Science Press (34):