Fluorescein tear breakup time measurement disrupts tear film stability

被引:0
|
作者
Lin, Meng C. [1 ,2 ]
Graham, Andrew D. [3 ]
Yeh, Thao [2 ]
Yuen, Tiffany [3 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Vis Sci Grad Program, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Sch Optometry, Clin Res Ctr, Berkeley, CA 94720 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
引用
收藏
页数:2
相关论文
共 50 条
  • [1] EFFECTS OF FLUORESCEIN ON TEAR BREAKUP TIME AND ON TEAR THINNING TIME
    PATEL, S
    MURRAY, D
    MCKENZIE, A
    SHEARER, DS
    MCGRATH, BD
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1985, 62 (03): : 188 - 190
  • [2] Agreement between invasive and noninvasive measurement of tear film breakup time
    Dorota H. Szczesna-Iskander
    Clara Llorens-Quintana
    Scientific Reports, 14
  • [3] Agreement between invasive and noninvasive measurement of tear film breakup time
    Szczesna-Iskander, Dorota H.
    Llorens-Quintana, Clara
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [4] Tear Film Breakup Time in Diabetic Patients
    Zaman, Saliha
    Samuel, Eileen
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (07): : 774 - 774
  • [5] Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye
    Paugh, Jerry R.
    Tse, June
    Nguyen, Tiffany
    Sasai, Alan
    Chen, Elaine
    De Jesus, Melinda Thomas
    Kwan, Justin
    Nguyen, Andrew Loc
    Farid, Marjan
    Garg, Sumit
    Jester, James, V
    CORNEA, 2020, 39 (01) : 92 - 98
  • [6] Impact of Soft Contact Lens Wear on Tear Film Breakup Patterns, Meniscus Tear Volume, and Tear Film Stability
    Yokoi, Norihiko
    Sakai, Rieko
    Georgiev, Georgi As
    Kato, Hiroaki
    Sotozono, Chie
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] INTERPRETATION OF TEAR FILM BREAKUP
    VANLEY, GT
    LEOPOLD, IH
    GREGG, TH
    ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (03) : 445 - 448
  • [8] Comparative analysis of tear film stability Automated non-invasive and fluorescein tear break-up time
    Zeri, F.
    Rizzo, G. C.
    Ponzini, E.
    Borghesi, A.
    Tavazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2024, 47 (05):
  • [9] Reliability of a new modified tear breakup time method: dry tear breakup time
    Kim, Kyung Tae
    Kim, Jae-hyung
    Kong, Young Tae
    Chae, Ju Byung
    Hyung, Sungmin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (08) : 1355 - 1361
  • [10] Tear breakup dynamics: A technique for quantifying tear film instability
    Begley, CG
    Himebaugh, N
    Renner, D
    Liu, HX
    Chalmers, R
    Simpson, T
    Varikooty, J
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (01) : 15 - 21