Agreement between invasive and noninvasive measurement of tear film breakup time

被引:0
|
作者
Dorota H. Szczesna-Iskander
Clara Llorens-Quintana
机构
[1] Wroclaw University of Science and Technology,Department of Optics and Photonics, Faculty of Fundamental Problems of Technology
[2] Complutense University of Madrid,Department of Optometry and Vision, Faculty of Optics and Optometry
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The agreement between fluorescein breakup time (FBUT) estimates and noninvasive breakup time (NIBUT) estimates automatically acquired using two videokeratoscopes was assessed. Small-cone (E300, Medmont) and large-bowl (K5M, OCULUS) Placido-ring–based videokeratoscopes were utilized for automated NIBUT estimation and fluorescein strip method was used for FBUT estimation. 33 subjects completed the study. Clear instructions were given regarding the blink before measurements. Bland–Altman analysis was used to test the agreement between tear film breakup time estimates and repeated measure analysis of variance was used to test the differences between measurement types. In comparison to FBUT, E300 NIBUT estimate was shorter (− 0.6 ± 2.6 s), whereas K5M NIBUT estimate was longer (3.3 ± 2.4 s). Limits of agreement for FBUT vs. E300 was 29.8 s, for FBUT vs. K5M 26.4 s, and 31.4 s for E300 vs. K5M. There were significant differences between tear film breakup times (F = 3.59, df = 2, P = 0.032). E300 and K5M NIBUT measurements have poor agreement with FBUT, even when blinking is precisely clarified. Agreement was better for shorted break up times than that for longer ones but in general NIBUT measurements are not interchangeable.
引用
收藏
相关论文
共 50 条
  • [1] Agreement between invasive and noninvasive measurement of tear film breakup time
    Szczesna-Iskander, Dorota H.
    Llorens-Quintana, Clara
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [2] Agreement between Automated and Traditional Measures of Tear Film Breakup
    Cox, Stephanie M.
    Nichols, Kelly K.
    Nichols, Jason J.
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (09) : E257 - E263
  • [3] Fluorescein tear breakup time measurement disrupts tear film stability
    Lin, Meng C.
    Graham, Andrew D.
    Yeh, Thao
    Yuen, Tiffany
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [4] Agreement and repeatability of four different devices to measure noninvasive tear breakup time (NIBUT)
    Bandlitz, Stefan
    Peter, Barbara
    Pflugi, Tanja
    Jaeger, Kai
    Anwar, Aaisha
    Bikhu, Paramdeep
    Nosch, Daniela S.
    Wolffsohn, James S.
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (05): : 507 - 511
  • [5] Tear Film Breakup Time in Diabetic Patients
    Zaman, Saliha
    Samuel, Eileen
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (07): : 774 - 774
  • [6] THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME
    CHO, P
    DOUTHWAITE, W
    OPTOMETRY AND VISION SCIENCE, 1995, 72 (01) : 17 - 22
  • [7] Relation between invasive and noninvasive tear break-up time
    Cho, Pauline
    Douthwaite, William
    Optometry and Vision Science, 1995, 72 (01):
  • [8] Simulation and measurement of Glob-Driven Tear Film Breakup
    Zhong, Lan
    Antwi, Deborah
    Braun, Richard J.
    King-Smith, Peter Ewen
    Begley, Carolyn G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [9] Evaluation of Age-Related Changes in Noninvasive Tear Breakup Time
    Hong, Jiaxu
    Liu, Zuguo
    Hua, Jing
    Wei, Anji
    Xue, Feng
    Yang, Yujing
    Sun, Xinghuai
    Xu, Jianjiang
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : 150 - 155
  • [10] Automatic Noninvasive Tear Breakup Time (TBUT) and Conventional Fluorescent TBUT
    Lan, Weizhong
    Lin, Lixia
    Yang, Xiao
    Yu, Minbin
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (12) : 1412 - 1418