Linear Mandibular Measurements: Comparison Between Orthopantomograms and Lateral Cephalograms

被引:29
|
作者
Ongkosuwito, E. M. [1 ]
Dieleman, M. M. J. [2 ]
Kuijpers-Jagtman, A. M. [3 ,4 ]
Mulder, P. G. H. [5 ]
van Neck, J. W. [6 ]
机构
[1] Univ Med Ctr, Erasmus MC, Dept Orthodont, Rotterdam, Netherlands
[2] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Rotterdam, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Cleft Palate Craniofacial Unit, Nijmegen, Netherlands
[5] Univ Med Ctr, Erasmus MC, Dept Epidemiol & Biostat, Rotterdam, Netherlands
[6] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Res Unit, Rotterdam, Netherlands
来源
CLEFT PALATE-CRANIOFACIAL JOURNAL | 2009年 / 46卷 / 02期
关键词
cephalometry; craniofacial; facial asymmetry; mandible; orthodontics; orthopantomography (OPT); reproducibility of results; ROTATIONAL PANORAMIC RADIOGRAPHY; HEAD FILM MEASUREMENTS; HEMIFACIAL MICROSOMIA; CEPHALOMETRIC LANDMARKS; REPRODUCIBILITY; ASYMMETRY; IDENTIFICATION; RELIABILITY; IMAGES; ERROR;
D O I
10.1597/07-123.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective; To investigate the reliability of length measurements of the mandible by comparing orthopantomograms (OPTs) with lateral cephalograms. Design: Observational study. Setting: OPTs and lateral cephalograms were taken of 20 human dry skulls. Four orthodontists and four maxillofacial surgeons located landmarks on all radiographs using a computer program for cephalometric measurements. Intraobserver and Interobserver variability in locating landmarks was assessed, as well as positioning of the skulls prior to radiography between the x-ray assistants. Magnification differences between the left and right side of the mandible on the OPT were determined for five skulls. Kappa statistics were used to calculate the Intraclass correlation coefficient for intraobserver and interobserver differences. An F test was used to assess differences between methods and between type of observer. Results: No significant differences were found in the magnification factor of the left and right side of the mandible. Compared with a lateral cephalogram, the OPT had comparable reliability in measuring mandibular distances condylion-gonion, gonion-menton, and condylion-menton. No significant differences were observed between the x-ray assistants in taking the OPTs and lateral cephalograms or In repositioning the skulls. Significant differences were found between orthodontists and maxillofacial surgeons for landmark measurements. Conclusion: An OPT is as reliable as a lateral cephalogram for linear measurements of the mandible (condylion-gonion, gonion-menton, and condylion-menton).
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [31] Comparison of accuracy of the maxillary sinus area and dimensions for sex estimation lateral cephalograms of Iranian samples
    Abasi, Pegah
    Ghodousi, Arash
    Ghafari, Roshanak
    Abbasi, Somayeh
    JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2019, 17 : 18 - 22
  • [32] Assessing the length of the mandibular ramus and the condylar process: a comparison of OPG, CBCT, CT, MRI, and lateral cephalometric measurements
    Markic, Goran
    Mueller, Lukas
    Patcas, Raphael
    Roos, Malgorzata
    Lochbuehler, Nina
    Peltomaki, Timo
    Karlo, Christoph A.
    Ullrich, Oliver
    Kellenberger, Christian J.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (01) : 13 - 21
  • [33] Comparison of measurements of mandible growth using cone beam computed tomography and its synthesized cephalograms
    Hsien-Shu Lin
    Jia-Da Li
    Yunn-Jy Chen
    Cheng-Chung Lin
    Tung-Wu Lu
    Mu-Hsiung Chen
    BioMedical Engineering OnLine, 13
  • [34] No correlation between mandibular and non-mandibular measurements in osteoporotic men
    Cakur, Binali
    Dagistan, Saadettin
    Suembuellue, Muhammed Akif
    ACTA RADIOLOGICA, 2010, 51 (07) : 789 - 792
  • [35] Comparison of measurements of mandible growth using cone beam computed tomography and its synthesized cephalograms
    Lin, Hsien-Shu
    Li, Jia-Da
    Chen, Yunn-Jy
    Lin, Cheng-Chung
    Lu, Tung-Wu
    Chen, Mu-Hsiung
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [36] Histomorphometric, Immunohistochemical and Microtomographic Comparison between Autogenous and Xenogenous Bone Blocks for Mandibular Lateral Augmentation in Rabbits
    Silva, Erick Ricardo
    Balan, Vitor Ferreira
    Botticelli, Daniele
    Soldini, Claudio
    Okamoto, Roberta
    Xavier, Samuel Porfirio
    MATERIALS, 2021, 14 (20)
  • [37] Evaluation and comparison of postero-anterior cephalograms and cone-beam computed tomography images for the detection of mandibular asymmetry
    Damstra, Janalt
    Fourie, Zacharias
    Ren, Yijin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (01) : 45 - 50
  • [38] MANDIBULAR REMODELING MEASURED ON CEPHALOGRAMS .2. A COMPARISON OF INFORMATION FROM IMPLANT AND ANATOMIC BEST-FIT SUPERIMPOSITIONS
    BAUMRIND, S
    BENBASSAT, Y
    KORN, EL
    BRAVO, LA
    CURRY, S
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1992, 102 (03) : 227 - 238
  • [39] Measurements of mandibular length:: A comparison of articulare vs condylion
    Haas, DW
    Martínez, F
    Eckert, GJ
    Diers, NR
    ANGLE ORTHODONTIST, 2001, 71 (03) : 210 - 215
  • [40] Comparison between conventional and cone-beam computed tomography-generated cephalograms
    Cattaneo, Paolo M.
    Bloch, Christian Borgkvist
    Calmar, Dorte
    Hjortshoj, Mette
    Melsen, Birte
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (06) : 798 - 802