Linear Mandibular Measurements: Comparison Between Orthopantomograms and Lateral Cephalograms

被引:29
|
作者
Ongkosuwito, E. M. [1 ]
Dieleman, M. M. J. [2 ]
Kuijpers-Jagtman, A. M. [3 ,4 ]
Mulder, P. G. H. [5 ]
van Neck, J. W. [6 ]
机构
[1] Univ Med Ctr, Erasmus MC, Dept Orthodont, Rotterdam, Netherlands
[2] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Rotterdam, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Cleft Palate Craniofacial Unit, Nijmegen, Netherlands
[5] Univ Med Ctr, Erasmus MC, Dept Epidemiol & Biostat, Rotterdam, Netherlands
[6] Univ Med Ctr, Erasmus MC, Dept Plast & Reconstruct Surg, Res Unit, Rotterdam, Netherlands
来源
CLEFT PALATE-CRANIOFACIAL JOURNAL | 2009年 / 46卷 / 02期
关键词
cephalometry; craniofacial; facial asymmetry; mandible; orthodontics; orthopantomography (OPT); reproducibility of results; ROTATIONAL PANORAMIC RADIOGRAPHY; HEAD FILM MEASUREMENTS; HEMIFACIAL MICROSOMIA; CEPHALOMETRIC LANDMARKS; REPRODUCIBILITY; ASYMMETRY; IDENTIFICATION; RELIABILITY; IMAGES; ERROR;
D O I
10.1597/07-123.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective; To investigate the reliability of length measurements of the mandible by comparing orthopantomograms (OPTs) with lateral cephalograms. Design: Observational study. Setting: OPTs and lateral cephalograms were taken of 20 human dry skulls. Four orthodontists and four maxillofacial surgeons located landmarks on all radiographs using a computer program for cephalometric measurements. Intraobserver and Interobserver variability in locating landmarks was assessed, as well as positioning of the skulls prior to radiography between the x-ray assistants. Magnification differences between the left and right side of the mandible on the OPT were determined for five skulls. Kappa statistics were used to calculate the Intraclass correlation coefficient for intraobserver and interobserver differences. An F test was used to assess differences between methods and between type of observer. Results: No significant differences were found in the magnification factor of the left and right side of the mandible. Compared with a lateral cephalogram, the OPT had comparable reliability in measuring mandibular distances condylion-gonion, gonion-menton, and condylion-menton. No significant differences were observed between the x-ray assistants in taking the OPTs and lateral cephalograms or In repositioning the skulls. Significant differences were found between orthodontists and maxillofacial surgeons for landmark measurements. Conclusion: An OPT is as reliable as a lateral cephalogram for linear measurements of the mandible (condylion-gonion, gonion-menton, and condylion-menton).
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [21] Assessing mandibular body changes in growing subjects: a comparison of CBCT and reconstructed lateral cephalogram measurements
    Cinzia Maspero
    Marco Farronato
    Francesca Bellincioni
    Davide Cavagnetto
    Andrea Abate
    Scientific Reports, 10
  • [22] Assessing mandibular body changes in growing subjects: a comparison of CBCT and reconstructed lateral cephalogram measurements
    Maspero, Cinzia
    Farronato, Marco
    Bellincioni, Francesca
    Cavagnetto, Davide
    Abate, Andrea
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [23] COMPARISON BETWEEN LATERAL AND AXIAL ULTRASONIC MEASUREMENTS OF THE FETAL FEMUR
    ABRAMOWICZ, J
    JAFFE, R
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 159 (04) : 921 - 922
  • [25] Heritability of craniofacial characteristics between parents and offspring estimated from lateral cephalograms
    Johannsdottir, B
    Thorarinsson, F
    Thordarson, A
    Magnusson, TE
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 127 (02) : 200 - 207
  • [26] Correlation between lateral cephalometric and facial photographic measurements for orthodontic diagnosis in patients with mandibular deficiency
    Tariq, Shahzonia
    Amjad, Nazish
    Hasnain, Muhammad
    Shafiq, Ayesha
    Khan, Asma Najib Ullah
    Zeb, Haseeb Alam
    KHYBER MEDICAL UNIVERSITY JOURNAL-KMUJ, 2023, 15 (04): : 254 - 257
  • [27] A comparison between cutting torque and resonance frequency measurements of mandibular implants.
    Pessoa, T
    Nary, HF
    Francischone, CE
    Falcao, R
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 131 - 131
  • [29] Precision of measurements on conventional negative 'bones white' and inverted greyscale 'bones black' digital lateral cephalograms
    Borrie, Felicity
    Thomson, Donald
    McIntyre, Grant T.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (01) : 57 - 61
  • [30] Correspondence Between Subjective and Linear Measurements of the Palatal Airway on Lateral Cephalometric Radiographs
    Bitar, Mohamed A.
    Macari, Anthony T.
    Ghafari, Joseph G.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2010, 136 (01) : 43 - 47