A review of rapid and field-portable analytical techniques for the diagnosis of cyanide exposure

被引:56
|
作者
Jackson, Randy [1 ]
Logue, Brian A. [1 ]
机构
[1] S Dakota State Univ, Dept Chem & Biochem, Box 2202, Brookings, SD 57007 USA
关键词
Cyanide detection; Sensor; Cyanide poisoning diagnosis; Bioanalysis; URANINE-SENSITIZED CHEMILUMINESCENCE; CDSE QUANTUM DOTS; BLOOD CYANIDE; GAS-CHROMATOGRAPHY; HYDROGEN-CYANIDE; 2-AMINO-2-THIAZOLINE-4-CARBOXYLIC ACID; SPECTROPHOTOMETRIC DETERMINATION; COLORIMETRIC DETECTION; SELECTIVE CHEMOSENSOR; FLUORESCENT SENSOR;
D O I
10.1016/j.aca.2016.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Another relatively common, but consistently overlooked, mode of cyanide exposure is inhalation of fire smoke. Both civilians and fire rescue personnel risk exposure during the unfortunate event of a structure fire. Additionally, fire rescue personnel risk long-term effects of habitual exposure throughout their careers in fire rescue. The relatively rapid onset of cyanide toxicity and the fact that cyanide exposure symptoms mimic other medical conditions necessitate a rapid, sensitive, portable, and accurate method for the diagnosis of cyanide exposure. This review focuses on the important issues concerning accurate point-of-care diagnosis of cyanide exposure and cyanide detection technologies that may allow a commercial cyanide exposure diagnostic to become a reality. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 39
页数:22
相关论文
共 50 条
  • [21] Field-portable and handheld laser-induced breakdown spectroscopy: Historical review, current status and future prospects
    Senesi, Giorgio S.
    Harmon, Russell S.
    Hark, Richard R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 175
  • [22] Field-portable X-ray fluorescence spectrometry as rapid measurement tool for landfill mining operations: comparison of field data vs. laboratory analysis
    Burlakovs, Juris
    Kaczala, Fabio
    Orupold, Kaja
    Bhatnagar, Amit
    Vincevica-Gaile, Zane
    Rudovica, Vita
    Kriipsalu, Mait
    Hogland, Marika
    Stapkevica, Mara
    Hogland, William
    Klavins, Maris
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (07) : 609 - 617
  • [23] The Applicability of Field-Portable GC MS for the Rapid Sampling and Measurement of High-Boiling-Point Semivolatile Organic Compounds in Environmental Samples
    Tai Van Truong
    Porter, Nathan L.
    Lee, Edgar D.
    Thomas, Robert J.
    LC GC NORTH AMERICA, 2016, : 30 - 36
  • [24] Field-portable X-ray fluorescence spectrometry as rapid measurement tool for landfill mining operations: comparison of field data vs. laboratory analysis
    Department of Environmental Science, University of Latvia, Riga
    LV-1586, Latvia
    不详
    391 82, Sweden
    不详
    51014, Estonia
    不详
    FI-70211, Finland
    不详
    LV-1586, Latvia
    Int. J. Environ. Anal. Chem., 7 (609-617):
  • [25] Rapid field based analytical techniques for the environmental screening of abandoned mine sites
    Coetzee, Henk
    RELIABLE MINE WATER TECHNOLOGY: PROCEEDINGS OF THE INTERNATIONAL MINE WATER ASSOCIATION ANNUAL CONFERENCE 2013, VOLS I & II, 2013, : 943 - 948
  • [26] Nondestructive and Rapid Screening of Aflatoxin-Contaminated Single Peanut Kernels Using Field-Portable Spectroscopy Instruments (FT-IR and Raman)
    Yao, Siyu
    Miyagusuku-Cruzado, Gonzalo
    West, Megan
    Nwosu, Victor
    Dowd, Eric
    Fountain, Jake
    Giusti, M. Monica
    Rodriguez-Saona, Luis E.
    FOODS, 2024, 13 (01)
  • [27] A Review of Analytical Techniques and Their Application in Disease Diagnosis in Breathomics and Salivaomics Research
    Beale, David J.
    Jones, Oliver A. H.
    Karpe, Avinash V.
    Dayalan, Saravanan
    Oh, Ding Yuan
    Kouremenos, Konstantinos A.
    Ahmed, Warish
    Palombo, Enzo A.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2017, 18 (01):
  • [28] ANALYSIS OF SILICATE ROCKS USING FIELD-PORTABLE X-RAY-FLUORESCENCE INSTRUMENTATION INCORPORATING A MERCURY(II) IODIDE DETECTOR - A PRELIMINARY ASSESSMENT OF ANALYTICAL PERFORMANCE
    POTTS, PJ
    WEBB, PC
    WILLIAMSTHORPE, O
    KILWORTH, R
    ANALYST, 1995, 120 (05) : 1273 - 1278
  • [29] Immunoserology and molecular techniques for diagnosis of Chagas' disease: rapid systematic review
    Gonzalez, Lucas
    Scollo, Karenina
    Bardach, Ariel
    Saez-Alquezar, Amadeo
    Ferlin, Carina
    Albajar-Vinas, Pedro
    Ciapponi, Agustin
    Sosa-Estani, Sergio
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2017, 51 (01): : 63 - 74
  • [30] Rapid detection of foot-and-mouth disease virus using a field-portable nucleic acid extraction and real-time PCR amplification platform
    Madi, Mikidache
    Hamilton, Andrea
    Squirrell, David
    Mioulet, Valerie
    Evans, Phillip
    Lee, Martin
    King, Donald P.
    VETERINARY JOURNAL, 2012, 193 (01): : 67 - 72