Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation

被引:60
|
作者
Takao, Masaki [1 ]
Nishii, Takashi [2 ]
Sakai, Takashi [1 ]
Yoshikawa, Hideki [1 ]
Sugano, Nobuhiko [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Orthopaed Med Engn, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
Iliosacral screw; Navigation; 3D fluoroscopy; CT-based plan; SACROILIAC SCREWS; PLACEMENT; FLUOROSCOPY; FIXATION; SYSTEM; FRACTURES; ACCURACY; REGIONS;
D O I
10.1016/j.injury.2014.01.015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Percutaneous iliosacral screw insertion requires substantial experience and detailed anatomical knowledge to find the proper entry point and trajectory even with the use of a navigation system. Our hypothesis was that three-dimensional (3D) fluoroscopic navigation combined with a preoperative computed tomography (CT)-based plan could enable surgeons to perform safe and reliable iliosacral screw insertion. The purpose of the current study is two-fold: (1) to demonstrate the navigation accuracy for sacral fractures and sacroiliac dislocations on widely displaced cadaveric pelves; and (2) to report the technical and clinical aspects of percutaneous iliosacral screw insertion using the CT-3D-fluoroscopy matching navigation system. Methods: We simulated three types of posterior pelvic ring disruptions with vertical displacements of 0, 1, 2 and 3 cm using cadaveric pelvic rings. A total of six fiducial markers were fixed to the anterior surface of the sacrum. Target registration error over the sacrum was assessed with the fluoroscopic imaging centre on the second sacral vertebral body. Six patients with pelvic ring fractures underwent percutaneous iliosacral screw placement using the CT-3D-fluoroscopy matching navigation. Three pelvic ring fractures were classified as type B2 and three were classified as type C1 according to the AO-OTA classification. Iliosacral screws for the S1 and S2 vertebra were inserted. Results: The mean target registration error over the sacrum was 1.2 mm (0.5-1.9 mm) in the experimental study. Fracture type and amount of vertical displacement did not affect the target registration error. All 12 screws were positioned correctly in the clinical series. There were no postoperative complications including nerve palsy. The mean deviation between the planned and the inserted screw position was 2.5 mm at the screw entry point, 1.8 mm at the area around the nerve root tunnels and 2.2 mm at the tip of the screw. Conclusion: The CT-3D-fluoroscopy matching navigation system was accurate and robust regardless of pelvic ring fracture type and fragment displacement. Percutaneous iliosacral screw insertion with the navigation system is clinically feasible. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:988 / 994
页数:7
相关论文
共 50 条
  • [31] Percutaneous Sacroiliac Screw Fixation: A Modified Screw Insertion Method Using Just 2 Fluoroscopy Views
    Dehkhoda, Farshid
    Rasi, Alireza Manafi
    Zandi, Reza
    Abedi, Maryam
    Ebadi, Seyed Shayan
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (08): : 574 - 579
  • [32] Portable CT scanner-based navigation in lumbar pedicle screw insertion
    Barsa, Pavel
    Suchomel, Petr
    EUROPEAN SPINE JOURNAL, 2013, 22 (06) : 1446 - 1450
  • [33] Percutaneous CT guided iliosacral screw placement using local anesthesia and conscious sedation
    Towers, JD
    Ziran, BH
    RADIOLOGY, 1997, 205 : 582 - 582
  • [34] Navigation Versus Fluoroscopy in Multilevel MIS Pedicle Screw Insertion Separate Analysis of Exposure to Radiation of the Surgeon and of the Patients
    Konieczny, Markus R.
    Krauspe, Ruediger
    CLINICAL SPINE SURGERY, 2019, 32 (05): : E258 - E265
  • [35] Percutaneous Screw Fixation for Traumatic Spondylolisthesis of the Axis Using Iso-C3D Fluoroscopy-Assisted Navigation (Case Report)
    Sugimoto, Y.
    Ito, Y.
    Shimokawa, T.
    Shiozaki, Y.
    Mazaki, T.
    MINIMALLY INVASIVE NEUROSURGERY, 2010, 53 (02) : 83 - 85
  • [36] 3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study
    Chan, Andrew
    Parent, Eric
    Mahood, Jim
    Lou, Edmond
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (02) : 271 - 281
  • [37] 3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study
    Andrew Chan
    Eric Parent
    Jim Mahood
    Edmond Lou
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 271 - 281
  • [38] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Bredow, Jan
    Meyer, Carolin
    Scheyerer, Max Joseph
    Siedek, Florian
    Mueller, Lars Peter
    Eysel, Peer
    Stein, Gregor
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1683 - 1689
  • [39] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Jan Bredow
    Carolin Meyer
    Max Joseph Scheyerer
    Florian Siedek
    Lars Peter Müller
    Peer Eysel
    Gregor Stein
    European Spine Journal, 2016, 25 : 1683 - 1689
  • [40] Conventional fluoroscopy-guided percutaneous placement of iliosacral screws in the era of intraoperative 3D imaging and navigation: inappropriate or still a valid option?
    Kuttner, H.
    Benninger, E.
    Meier, C.
    BRITISH JOURNAL OF SURGERY, 2019, 106 : 22 - 22