Numerical modeling of the performance of differential mobility analyzers for nanometer aerosol measurements

被引:49
|
作者
Chen, DR
Pui, DYH
机构
[1] Particle Technology Laboratory, Mechanical Engineering Department, University of Minnesota, Minneapolis, MN 55455
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0021-8502(97)00004-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A numerical model was developed to predict the performance of differential mobility analyzers (DMAs) for nanometer aerosol measurements. The model consists of three parts: flow field, electric field, and aerosol transport formulations. In order for the model to be applicable for all the existing DMAs, the swirling flow effect due to tangential aerosol injection is included. The tangential inlet design was used in several recently designed DMAs, e.g. Hauke, SMEC and RDMA. The swirling is incorporated in the model by introducing the assumption of negligible variation of the circumferential flow component. Mixed Galerkin and SUPG finite-element formulations with a nine-node velocity, three-node pressure flow elements and bilinear element are proposed. For the electric field, the space charge effect is neglected and the equation is solved by Galerkin finite element method with the second-order isoparametric element. The aerosol transport is modeled by the convective aerosol transport equation with external electrical force. The equation is further simplified by using the same assumption made for the flow field in the circumferential Bow component. A modified adaptive characteristic Petrov-Galerkin finite-element method is proposed to overcome the difficulty involved in numerically solving the simplified equation. The model was used to calculate the transfer functions of TSI-short DMA for particle sizes between 5 and 50 nm. They were then validated by comparing the numerical and experimental results for simulated scans from two DMAs operating in series. The numerical transfer functions are compared with the available experimental data from two sources, namely, Hummes et al. (1996) Part, Part. System Charact. 13, 327-332 and Kousaka et al. (1986) J. Chem. Engng Japan 19, 401-407. A good agreement between them is obtained. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:985 / 1004
页数:20
相关论文
共 50 条
  • [1] Numerical modeling of the performance of the differential mobility analyzer for nanometer aerosol measurements
    Chen, D.
    Pui, D.Y.H.
    [J]. Journal of Aerosol Science, 1995, 26 (Suppl 1):
  • [2] Experimental comparison of four differential mobility analyzers for nanometer aerosol measurements
    Fissan, H
    Hummes, D
    Stratmann, F
    Buscher, P
    Neumann, S
    Pui, DYH
    Chen, D
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1996, 24 (01) : 1 - 13
  • [3] Determination of the Mean Mobility of Aerosol Nanoparticles Classified by Differential Mobility Analyzers
    Alonso, M.
    Gomez, V.
    Borra, J. P.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (12) : 1217 - 1225
  • [4] Effect of Aerosol Volatility on the Sizing Accuracy of Differential Mobility Analyzers
    Khlystov, Andrey
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (06) : 604 - 619
  • [5] On the radial flow differential mobility analyzers for the determination of aerosol particle density and mass
    Boulaud, D.
    Pourprix, M.
    Gougeon, R.
    Le Bronec, E.
    Renoux, A.
    [J]. Journal of Aerosol Science, 1996, 27 (Suppl 1):
  • [6] Performance Study of SMPS and FDMA for Nanometer Aerosol Particle Measurements
    Chang, Chang Tang
    Ma, Chih Ming
    Hong, Gui Bing
    Huang, Ham Sun
    Chen, Da Ren
    [J]. ADVANCED MATERIALS RESEARCH, 2011, 213 : 39 - +
  • [7] Design and evaluation of a nanometer aerosol differential mobility analyzer (Nano-DMA)
    Chen, DR
    Pui, DYH
    Hummes, D
    Fissan, H
    Quant, FR
    Sem, GJ
    [J]. JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) : 497 - 509
  • [8] A review of transfer theory and characterization of measured performance for differential mobility analyzers
    Stolzenburg, Mark R.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2018, 52 (10) : 1194 - 1218
  • [10] Nanometer-sized silver particle measurements by low pressure differential mobility analyzer and its classification performance
    Kuga, Y
    Furuyama, Y
    Ando, K
    Okuyama, K
    Takeuchi, K
    [J]. KAGAKU KOGAKU RONBUNSHU, 2000, 26 (06) : 776 - 784