Nanometer-sized silver particle measurements by low pressure differential mobility analyzer and its classification performance

被引:2
|
作者
Kuga, Y [1 ]
Furuyama, Y
Ando, K
Okuyama, K
Takeuchi, K
机构
[1] Muroran Inst Technol, Dept Appl Chem, Muroran, Hokkaido 0508585, Japan
[2] Hiroshima Univ, Dept Chem Engn, Higashihiroshima 7398527, Japan
[3] Inst Phys & Chem Res, RIKEN, Wako, Saitama 351, Japan
关键词
differential mobility analyzer (DMA); low pressure; TEM; nm-sized particles; classification;
D O I
10.1252/kakoronbunshu.26.776
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Size distribution measurements and classification performance tests under low pressure conditions ranging from 123 to 300 Torr were systematically carried out for nano-meter sized silver particles formed in a nitrogen gas flow at atmospheric pressure using a new type of differential mobility analyzer (LPDMA) based on the Vienna type design concept which has a short classification zone. Although the values of the volumetric average diameter, D-V,D-DMA, are approximately 7% larger than those of the volumetric average diameter, D-V,D-TEM, obtained from the transmission electron microscope (TEM) observation results of the silver particles collected at the LPDMA inlet, both the DMA and TEM size measurements are found to have good correlation in the range from 6 to 15 nm. When the ratio of the sheath gas flow rate and aerosol gas flow rate is set at 5:1, the theoretical sizes calculated from the classification voltage applied to the LPDMA at 160 Torr are also found to be in good correlation with those of D-V,D-TEM obtained from the TEM observation results of the silver particles collected after the classification by the LPDMA in the range from 6 to 25 nm, although the theoretical sizes set by the LPDMA are approximately 14% larger than those of D-V,D-TEM measured from the TEM observation results after the classification by the LPDMA. The geometric standard deviations of the size distributions obtained from the TEM images after classification range from 1.08 to 1.17, and they are approximately equal to the theoretical value (1.093) of the particles classified by the LPDMA, which is derived from the assumption that the broadening effects by Brownian diffusion are ignored, whereas the geometric standard deviations of the size distributions obtained from the TEM images before the classification range from 1.34 to 1.50 and are greater than those after classification. Thus, we experimentally demonstrate the validity of our LPDMA system in size measurements and classification of the nm-sized particles under low pressure conditions.
引用
收藏
页码:776 / 784
页数:9
相关论文
共 49 条
  • [1] Classification Performance of a Low Pressure Differential Mobility Analyzer for Nanometer-sized Particles
    Yoshikazu Kuga
    Keiko Okauchi
    Daiki Takeda
    Yuichi Ohira
    Koji Ando
    [J]. Journal of Nanoparticle Research, 2001, 3 : 175 - 183
  • [2] Classification performance of a low pressure differential mobility analyzer for nanometer-sized particles
    Kuga, Y
    Okauchi, K
    Takeda, D
    Ohira, Y
    Ando, K
    [J]. JOURNAL OF NANOPARTICLE RESEARCH, 2001, 3 (2-3) : 175 - 183
  • [3] Radial Differential Mobility Analyzer for One Nanometer Particle Classification
    Brunelli, N. A.
    Flagan, R. C.
    Giapis, K. P.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 53 - 59
  • [4] Numerical modeling of the performance of the differential mobility analyzer for nanometer aerosol measurements
    Chen, D.
    Pui, D.Y.H.
    [J]. Journal of Aerosol Science, 1995, 26 (Suppl 1):
  • [5] Particle Classification by the Tandem Differential Mobility Analyzer-Particle Mass Analyzer System
    Kuwata, Mikinori
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2015, 49 (07) : 508 - 520
  • [6] DMA for measurement of nanometer-sized particles formed at very-low pressure
    Seol, K.S.
    Okada, Y.
    Okuyama, K.
    Takeuchi, K.
    [J]. 1600, Elsevier Science Ltd, Exeter, United Kingdom (31):
  • [7] A DMA for measurement of nanometer-sized particles formed at very-low pressure
    Seol, K.S.
    Okada, Y.
    Okuyama, K.
    Takeuchi, K.
    [J]. Journal of Aerosol Science, 2000, 31 (SUPPL.1)
  • [8] Technique for aerosol flow check in differential mobility analyzer and its influence on classification performance
    Otani, Y
    Emi, H
    Cho, SJ
    Okuyama, K
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1997, 30 (06) : 1065 - 1069
  • [9] Performance of Vienna type differential mobility analyzer at 1.2-20 nanometer
    Reischl, GP
    Makela, JM
    Necid, J
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (06) : 651 - 672
  • [10] Performance of Vienna type differential mobility analyzer at 1.2-20 Nanometer
    University of Vienna, Institute of Experimental Physics, Strudlhofgasse 4, A-1090 Vienna, Austria
    不详
    [J]. AEROSOL SCI. TECHNOL., 6 (651-672):