Particle deposition and decay in a chamber and the implications to exposure assessment

被引:10
|
作者
Lai, Alvin C. K. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
WATER AIR AND SOIL POLLUTION | 2006年 / 175卷 / 1-4期
关键词
particulate matter; deposition; inhalation transfer factor; exposure risk assessment; indoor air quality;
D O I
10.1007/s11270-006-9141-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate modeling indoor aerosol deposition and decay is an important step for exposure assessment. High deposition rate reduces indoor pollutant concentration and results in lower inhalation exposure. Many of indoor surfaces have random roughness protrusion scales up to several millimeters which it may significantly affect the deposition loss rate. Aerosols deposition onto most indoor surfaces can be considered as "rough' surface deposition. However, particle deposition from anleaflong indoor environment is frequently modeled by assuming that surfaces are smooth. In this work, experimental results for deposition velocity onto drywall surfaces for supermicron particles from 1 to 7 mu m are presented. Deposition velocity is significantly higher than that predicted by a previous published model. To illustrative the influence of particle deposition on exposure, two hypothetical room sizes and two air exchange rates were considered. Inhalation transfer factor was adopted as a risk exposure index. Taking into account of high deposition velocity onto drywall surfaces, inhalation transfer factors are 8 to 35% lower than that predicted by the model and this significant difference is important to the exposure assessment.
引用
收藏
页码:323 / 334
页数:12
相关论文
共 50 条
  • [21] Assessment of cigarette smoke particle deposition within the Vitrocell® exposure module using quartz crystal microbalances
    Jason Adamson
    David Thorne
    Annette Dalrymple
    Debbie Dillon
    Clive Meredith
    Chemistry Central Journal, 7
  • [22] Evaluation of particle deposition efficiency in the cell exposure system
    Fujitani, Yuji
    Sugaya, Yutaka
    Furuyama, Akiko
    Hirano, Seishiro
    Takami, Akinori
    Hashiguchi, Masanori
    29TH SYMPOSIUM ON AEROSOL SCIENCE AND TECHNOLOGY, 2012, 2012, : 49 - 50
  • [23] Critical assessment of particle decay as a probe to study the continuum
    Bianchini, A
    Liotta, RJ
    Sandulescu, N
    PHYSICAL REVIEW C, 2001, 63 (02): : 15
  • [24] Particle physics implications of neutrinoless double-beta decay
    Mohapatra, RN
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 77 : 376 - 385
  • [25] Implications of endogenous exposure for risk assessment
    Rietjens, I.
    Arand, M.
    Bolt, H.
    Bourdoux, S.
    Hartwig, A.
    Hinrichsen, N.
    Kalisch, C.
    Mally, A.
    Pellegrino, G.
    Ribera, D.
    Thatcher, N.
    Eisenbrand, G.
    TOXICOLOGY LETTERS, 2023, 384 : S25 - S25
  • [26] Seasonal variation of particle number concentration in a busy urban street with exposure assessment and deposition in human respiratory tract
    Rajagopal, Kanagaraj
    Ramachandran, S.
    Mishra, Rajeev Kumar
    Chemosphere, 2024, 366
  • [27] Numerical investigation on particle deposition in a chamber with an attached-wall heat source
    Chen, Xi
    Li, Angui
    Gao, Ran
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (05) : 640 - 652
  • [28] Allergen exposure chamber in the assessment of clinical outcomes of HDM AIT
    Kosowska, A.
    Zemelka-Wiacek, M.
    Jutel, M.
    ALLERGY, 2023, 78 : 180 - 181
  • [29] GROWTH AND AGING OF THE BRONCHIAL TREE - IMPLICATIONS FOR PARTICLE DEPOSITION CALCULATIONS
    PHALEN, RF
    OLDHAM, MJ
    SCHUM, GM
    RADIATION PROTECTION DOSIMETRY, 1991, 38 (1-3) : 15 - 21
  • [30] Methodology to estimate the amount and particle size of soil ingested by children. Implications for exposure assessment at waste sites
    Calabrese, EJ
    Stanek, EJ
    Barnes, R
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 1996, 24 (03) : 264 - 268