Programmable Current Source for Implantable Neural Stimulation Systems

被引:0
|
作者
Pistor, Jonas [1 ]
Heidmann, Nils [1 ]
Hoeffmann, Janpeter [1 ]
Paul, Steffen [1 ]
机构
[1] Univ Bremen, Inst Electrodynam & Microelect ITEM Me, D-28359 Bremen, Germany
关键词
biphasic stimulation; brain-computer interface; neural stimulation; biomedical; CMOS; integrated circuit;
D O I
10.1016/j.proeng.2014.11.720
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper we present an ASIC, built in a 350nm CMOS technology, as a component for a neural measurement and stimulation system. The ASIC consists of an adjustable current source and a switch matrix, which allows selecting sources and sinks out of 8 connected electrodes. The ASIC also contains a microsequencer and a memory, which can be configured and programmed using a serial data interface. The circuit allows to apply charge-balanced biphasic current stimulation to nervous tissue, as needed in implantable neural interfaces. (c) 2014 Published by Elsevier Ltd.
引用
收藏
页码:324 / 327
页数:4
相关论文
共 50 条
  • [31] An Implantable System for Neural Communication and Stimulation: Design and Implementation
    Vizziello, Anna
    Galluccio, Laura
    Magarini, Maurizio
    Savazzi, Pietro
    Biglioli, Federico
    Bolognesi, Federico
    Talpo, Francesca
    Biella, Gerardo
    Magenes, Giovanni
    IEEE COMMUNICATIONS MAGAZINE, 2022, 60 (08) : 74 - 79
  • [32] Design of Programmable Voltage Source in Micro-Current Detection System Based on Artificial Neural Network
    Wei, Qiang
    Wu, ShunWei
    Wang, Yan
    Zhang, Dong
    Hu, Chengzhong
    INTERNATIONAL CONFERENCE ON ELECTRICAL AND CONTROL ENGINEERING (ICECE 2015), 2015, : 825 - 830
  • [33] Implantable electronic device dedicated to neural stimulation and sensing
    Mounaim, F.
    Sawan, M.
    2006 INTERNATIONAL WORKSHOP ON COMPUTER ARCHITECTURE FOR MACHINE PERCEPTION AND SENSING, 2006, : 196 - +
  • [34] The Current State of Implantable Tibial Nerve Stimulation Therapy
    Hartman-Kenzler, Jacob
    Pizzuti, Joseph
    Kim, Jason
    CURRENT BLADDER DYSFUNCTION REPORTS, 2023, 18 (04) : 274 - 279
  • [35] The Current State of Implantable Tibial Nerve Stimulation Therapy
    Jacob Hartman-Kenzler
    Joseph Pizzuti
    Jason Kim
    Current Bladder Dysfunction Reports, 2023, 18 : 274 - 279
  • [36] Implantable FES stimulation systems: What is needed?
    Troyk, PR
    Donaldson, ND
    NEUROMODULATION, 2001, 4 (04): : 196 - 202
  • [37] Current-source power supply is digitally programmable
    Konrad, B
    ELECTRONIC DESIGN, 1999, 47 (16) : 114 - +
  • [38] A Least-Voltage Drop High Output Resistance Current Source for Neural Stimulation
    Sawigun, Chutham
    Ngamkham, Wannaya
    van Dongen, Marijn
    Serdijn, Wouter A.
    2010 BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2010, : 110 - 113
  • [39] Programmable current source for high-efficiency chargers
    Bell, D
    ELECTRONIC DESIGN, 1997, 45 (03) : 158 - 158
  • [40] Current mode circuits for programmable WTA neural network
    Wawryn, K
    Strzeszewski, B
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2001, 27 (1-2) : 49 - 69