Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

被引:9
|
作者
Yang, Ching-Ching [1 ]
Liu, Shu-Hsin [1 ,2 ]
Mok, Greta S. P. [3 ]
Wu, Tung-Hsin [4 ]
机构
[1] Tzu Chi Coll Technol, Dept Med Imaging & Radiol Sci, Hualien 970, Taiwan
[2] Buddhist Tzu Chi Gen Hosp, Dept Nucl Med, Hualien 970, Taiwan
[3] Univ Macau, Biomed Imaging Lab, Dept Elect & Comp Engn, Fac Sci & Technol, Macao, Peoples R China
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
关键词
pediatric patients; whole-body PET/CT; radiation dose; image quality; ATTENUATION CORRECTION; NUCLEAR-MEDICINE; SYSTEM; DOSIMETRY; ACCURACY; CHILDREN; SPECT; RISK;
D O I
10.1118/1.4893273
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Impact of Radiation Dose Reduction of CT component in Whole-Body PET/CT Protocols on CT Image quality
    Ali, I.
    Mohamed, Y.
    Naser, I.
    Amin, M. I.
    Gawad, H. Abdel
    Hamdy, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S782
  • [2] CT Radiation Dose Optimization in Whole-Body PET/CT Examination
    Tonkopi, E.
    Ross, A.
    MacDonald, A.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
    Jallow, Ngoneh
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John M.
    Nye, Jonathon A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 238 - 241
  • [4] Evaluation of radiation dose to pediatric models from whole body PET/CT imaging
    Mohammadi, Najmeh
    Akhlaghi, Parisa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [5] A RETROSPECTIVE EVALUATION OF RADIATION DOSE ASSOCIATED WITH LOW DOSE FDG PROTOCOLS IN WHOLE-BODY PET/CT
    Willowson, K.
    Bailey, E.
    Bailey, D.
    INTERNAL MEDICINE JOURNAL, 2012, 42 : 4 - 4
  • [6] A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT
    Kathy P. Willowson
    Elizabeth A. Bailey
    Dale L. Bailey
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 49 - 53
  • [7] A retrospective evaluation of radiation dose associated with low dose FDG protocols in whole-body PET/CT
    Willowson, Kathy P.
    Bailey, Elizabeth A.
    Bailey, Dale L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 49 - 53
  • [8] Optimization of 99mTc whole-body SPECT/CT image quality: A phantom study
    Alqahtani, Mansour M.
    Willowson, Kathy P.
    Constable, Chris
    Fulton, Roger
    Kench, Peter L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [9] Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
    Huang, Bingsheng
    Law, Martin Wai-Ming
    Khong, Pek-Lan
    RADIOLOGY, 2009, 251 (01) : 166 - 174
  • [10] JOURNAL CLUB: CT Dose Optimization for Whole-Body PET/CT Examinations
    Tonkopi, Elena
    Ross, Andrew A.
    MacDonald, Anita
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : 257 - 263