Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

被引:9
|
作者
Yang, Ching-Ching [1 ]
Liu, Shu-Hsin [1 ,2 ]
Mok, Greta S. P. [3 ]
Wu, Tung-Hsin [4 ]
机构
[1] Tzu Chi Coll Technol, Dept Med Imaging & Radiol Sci, Hualien 970, Taiwan
[2] Buddhist Tzu Chi Gen Hosp, Dept Nucl Med, Hualien 970, Taiwan
[3] Univ Macau, Biomed Imaging Lab, Dept Elect & Comp Engn, Fac Sci & Technol, Macao, Peoples R China
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
关键词
pediatric patients; whole-body PET/CT; radiation dose; image quality; ATTENUATION CORRECTION; NUCLEAR-MEDICINE; SYSTEM; DOSIMETRY; ACCURACY; CHILDREN; SPECT; RISK;
D O I
10.1118/1.4893273
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Estimates of the image quality in accordance with radiation dose for pediatric imaging using deep learning CT: A phantom study
    Jeon, Pil-Hyun
    Kim, Daehong
    Chung, Myung-Ae
    2022 IEEE INTERNATIONAL CONFERENCE ON BIG DATA AND SMART COMPUTING (IEEE BIGCOMP 2022), 2022, : 352 - 356
  • [42] Whole-body PET angiography on semiconductor PET/CT
    Norikane, Takashi
    Yamamoto, Yuka
    Takami, Yasukage
    Mitamura, Katsuya
    Matsumoto, Keisuke
    Maeda, Yukito
    Yamashita, Yoichi
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 885 - 888
  • [43] Whole-body PET angiography on semiconductor PET/CT
    Takashi Norikane
    Yuka Yamamoto
    Yasukage Takami
    Katsuya Mitamura
    Keisuke Matsumoto
    Yukito Maeda
    Yoichi Yamashita
    Yoshihiro Nishiyama
    Journal of Nuclear Cardiology, 2022, 29 : 885 - 888
  • [44] How Low Can You Go With Ultra-low-dose Tin Filter CT in PET-CT? Evaluation of Dose and Artifacts in a Whole-body Patient Phantom
    Bebbington, N.
    Christensen, K. B.
    Holdgaard, P. C.
    Ostergard, L. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S228 - S228
  • [45] Methods of CT Dose Estimation in Whole-Body 18F-FDG PET/CT
    Inoue, Yusuke
    Nagahara, Kazunori
    Tanaka, Yoshihito
    Miyatake, Hiroki
    Hata, Hirofumi
    Hara, Toshimasa
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (05) : 695 - 700
  • [46] Development of low dose CT protocols with acceptable CT image quality for CTAC of PET data: Phantom Study
    Mojabi, Z.
    Ghafarian, P.
    Ghadiri, H.
    Bakhshayeshkaram, M.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S476 - S476
  • [47] PET count rate performance and CT image quality of a 16-slice LSO PET/CT for clinical whole-body imaging
    Carney, JPJ
    Yap, JT
    Townsend, DW
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 963 - 965
  • [48] Evaluation of whole-body MR to CT deformable image registration
    Akbarzadeh, A.
    Gutierrez, D.
    Baskin, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Loevblad, K. O.
    Zaidi, H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 238 - 253
  • [49] A phantom study into constant image quality of low-dose CT in the pediatric population
    Caan, G. A.
    Almeida, A. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S649 - S649
  • [50] Evaluation of Image Quality and Quantification with Various Scan Times on 64 Copper PET/CT Imaging: Phantom and Clinical study
    Sadeghi, F.
    Monsef, A.
    Sheikhzadeh, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S704 - S704