CORRELATIONS AMONG ULTRASONOGRAPHIC MEASUREMENTS OF OPTIC NERVE SHEATH DIAMETER, AGE, AND BODY WEIGHT IN CLINICALLY NORMAL HORSES

被引:7
|
作者
Cooley, Stacy D. [1 ]
Scrivani, Peter V. [1 ]
Thompson, Margret S. [1 ]
Irby, Nita L. [1 ]
Divers, Thomas J. [1 ]
Erb, Hollis N. [2 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Coll Vet Med, Dept Populat Med & Diagnost Sci, Ithaca, NY 14853 USA
关键词
horse; intracranial pressure; optic nerve sheath diameter; ultrasonography; INCREASED INTRACRANIAL-PRESSURE; SEVERE BRAIN-INJURY; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; ULTRASOUND;
D O I
10.1111/vru.12300
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Early diagnosis of high intracranial pressure (ICP) is critical for minimizing progressive brain injury due to reduced cerebral perfusion. In people, detecting enlargement of the optic nerve sheath diameter (ONSD) by transpalpebral ultrasonography has been found to be an accurate test for high ICP. Aims of this prospective, observational, cross-sectional study were to test hypotheses that (1) ultrasonographic measurement of ONSD would be repeatable in horses, (2) have acceptable interobserver agreement, and (3) would be correlated with age and body weight. The sample population included 48 horses without clinical signs of high ICP and with varying ages and body weights. Two observers independently performed ONSD measurements in both eyes. All measurements ranged from 2.6 to 6.5 mm. The mean difference of repeated measures within observers was <= 0.1 mm and the coefficients of variation ranged from 5.0% to 8.8%. The mean difference of measures between observers was <= 0.2 mm. After correcting for performing multiple tests, no significant rank correlation (all r < 0.4 [absolute value]) was detected between ONSD and age or body weight. However, we observed smaller ONSD in foals versus adults (all P <= 0.002). In the foals, all observed measures of rostrocaudal and dorsoventral ONSD were < 5 mm. In the adults, all observed measures of rostrocaudal and dorsoventral ONSD were <= 6.5 mm. Findings indicated that ultrasonographic ONSD measurement is a feasible test for use in horses of varying ages and sizes. Further investigation of this ultrasonographic measure as a clinical test for horse with suspected high ICP is warranted. (C) 2015 American College of Veterinary Radiology.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [41] Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure
    Maissan, Iscander M.
    Dirven, Perjan J. A. C.
    Haitsma, Iain K.
    Hoeks, Sanne E.
    Gommers, Diederik
    Stolker, Robert Jan
    JOURNAL OF NEUROSURGERY, 2015, 123 (03) : 743 - 747
  • [42] Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
    Wang, Li-juan
    Yao, Yan
    Feng, Liang-shu
    Wang, Yu-zhi
    Zheng, Nan-nan
    Feng, Jia-chun
    Xing, Ying-qi
    SCIENTIFIC REPORTS, 2017, 7
  • [43] Optic Nerve Sheath Diameter on Sonography in Idiopathic Intracranial Hypertension Versus Normal
    Rehman, Hina
    Khan, Muhammad Saim
    Nafees, Muhammad
    Attique-ur-Rehman
    Habib, Asad
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (09): : 758 - 760
  • [44] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145
  • [45] Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter
    Blehar, David J.
    Gaspari, Romolo J.
    Montoya, Anthony
    Calderon, Richard
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (03) : 407 - 411
  • [46] The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma
    Nihan Şık
    Emel Ulusoy
    Hale Çitlenbik
    Ali Öztürk
    Anıl Er
    Durgül Yılmaz
    Murat Duman
    Journal of Ultrasound, 2022, 25 : 957 - 963
  • [47] Comparative reproducibility in ultrasound (US) optic nerve sheath diameter (ONSD) measurements
    Daly, Suzanne
    Coleman, D. Jackson
    Ben-Dov, Meital
    Silverman, Ronald H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [48] Bedside sonographic measurements of optic nerve sheath diameter in children with diabetic ketoacidosis
    Sik, Nihan
    Erbas, Ibrahim Mert
    Demir, Korcan
    Yilmaz, Durgul
    Duman, Murat
    PEDIATRIC DIABETES, 2021, 22 (04) : 618 - 624
  • [49] The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma
    Sik, Nihan
    Ulusoy, Emel
    Citlenbik, Hale
    Ozturk, Ali
    Er, Anil
    Yilmaz, Durgul
    Duman, Murat
    JOURNAL OF ULTRASOUND, 2022, 25 (04) : 957 - 963
  • [50] Comment on: Optic nerve sheath diameter measurement by ultrasound and age group Reply
    Yilmaz, Fevzi
    ANNALS OF SAUDI MEDICINE, 2023, 43 (03) : 196 - 197