CORRELATIONS AMONG ULTRASONOGRAPHIC MEASUREMENTS OF OPTIC NERVE SHEATH DIAMETER, AGE, AND BODY WEIGHT IN CLINICALLY NORMAL HORSES

被引:7
|
作者
Cooley, Stacy D. [1 ]
Scrivani, Peter V. [1 ]
Thompson, Margret S. [1 ]
Irby, Nita L. [1 ]
Divers, Thomas J. [1 ]
Erb, Hollis N. [2 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Coll Vet Med, Dept Populat Med & Diagnost Sci, Ithaca, NY 14853 USA
关键词
horse; intracranial pressure; optic nerve sheath diameter; ultrasonography; INCREASED INTRACRANIAL-PRESSURE; SEVERE BRAIN-INJURY; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; ULTRASOUND;
D O I
10.1111/vru.12300
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Early diagnosis of high intracranial pressure (ICP) is critical for minimizing progressive brain injury due to reduced cerebral perfusion. In people, detecting enlargement of the optic nerve sheath diameter (ONSD) by transpalpebral ultrasonography has been found to be an accurate test for high ICP. Aims of this prospective, observational, cross-sectional study were to test hypotheses that (1) ultrasonographic measurement of ONSD would be repeatable in horses, (2) have acceptable interobserver agreement, and (3) would be correlated with age and body weight. The sample population included 48 horses without clinical signs of high ICP and with varying ages and body weights. Two observers independently performed ONSD measurements in both eyes. All measurements ranged from 2.6 to 6.5 mm. The mean difference of repeated measures within observers was <= 0.1 mm and the coefficients of variation ranged from 5.0% to 8.8%. The mean difference of measures between observers was <= 0.2 mm. After correcting for performing multiple tests, no significant rank correlation (all r < 0.4 [absolute value]) was detected between ONSD and age or body weight. However, we observed smaller ONSD in foals versus adults (all P <= 0.002). In the foals, all observed measures of rostrocaudal and dorsoventral ONSD were < 5 mm. In the adults, all observed measures of rostrocaudal and dorsoventral ONSD were <= 6.5 mm. Findings indicated that ultrasonographic ONSD measurement is a feasible test for use in horses of varying ages and sizes. Further investigation of this ultrasonographic measure as a clinical test for horse with suspected high ICP is warranted. (C) 2015 American College of Veterinary Radiology.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [21] Normal measurements of the optic nerve, optic nerve sheath and optic chiasm in the adult population
    Mncube, Sanele S.
    Goodier, Matthew D.
    SA JOURNAL OF RADIOLOGY, 2019, 23 (01):
  • [22] Effect of Posture on Optic Nerve Sheath Diameter Ultrasound Measurements
    van der Most, R. N.
    Craig, D. G. N.
    Lee, A.
    SCOTTISH MEDICAL JOURNAL, 2010, 55 (02) : 55 - 55
  • [23] Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks
    Hirzallah, Mohammad I.
    Bose, Supratik
    Hu, Jingtong
    Maltz, Jonathan S.
    JOURNAL OF NEUROIMAGING, 2023, 33 (06) : 898 - 903
  • [24] Ultrasonographic evaluation of the diameter of the optic nerve sheath for medication of intracranial pressure: a case report
    Carrillo Esper, Raul
    Flores Rivera, Oscar Ivan
    Pena Perez, Carlos Alberto
    Carrillo Cordova, Luis Daniel
    Carrillo Cordova, Jorge Raul
    Carrillo Cordova, Carlos Alberto
    Carrillo Cordova, Dulce Maria
    GACETA MEDICA DE MEXICO, 2014, 150 (02): : 165 - 170
  • [25] Standardized Ultrasonographic Measurement of Optic Nerve Sheath Diameter in Traumatic Brain Injury Patients
    Graziano, Mario
    Sannino, Ciro
    Mottola, Francesco Ferdinando
    NEUROLOGY INDIA, 2023, 71 (04) : 792 - 792
  • [26] Ultrasonographic measurement of the optic nerve sheath diameter to detect intracranial hypertension: an observational study
    Yic, Christian Daniel
    Pontet, Julio
    Mercado, Mauricio
    Munoz, Matias
    Biestro, Alberto
    ULTRASOUND JOURNAL, 2023, 15 (01):
  • [27] Ultrasonographic measurement of the optic nerve sheath diameter to detect intracranial hypertension: an observational study
    Christian Daniel Yic
    Julio Pontet
    Mauricio Mercado
    Matias Muñoz
    Alberto Biestro
    The Ultrasound Journal, 15
  • [28] Optic nerve sheath diameter in normal-tension glaucoma patients
    Jaggi, Gregor Peter
    Miller, Neil Richard
    Flammer, Josef
    Weinreb, Robert N.
    Remonda, Luca
    Killer, Hanspeter Esriel
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (01) : 53 - 56
  • [29] OPTIC NERVE SHEATH DIAMETER: DEFINING A NORMAL VALUE IN THE CRITICALLY ILL
    Snyders, Brian
    Pack, Ryan
    Mickey, Walter
    Trottier, Steven
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 379 - 379
  • [30] Transorbital ultrasound measurement of optic nerve sheath diameter in normal rabbits
    Yang, Xi-Yue
    Yang, Jin-Ping
    Zhu, Lin-Ping
    Pan, Rui-Hui
    Huang, Yan-Ni
    Li, Zhi-Xian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 13412 - 13418