CORRELATIONS AMONG ULTRASONOGRAPHIC MEASUREMENTS OF OPTIC NERVE SHEATH DIAMETER, AGE, AND BODY WEIGHT IN CLINICALLY NORMAL HORSES

被引:7
|
作者
Cooley, Stacy D. [1 ]
Scrivani, Peter V. [1 ]
Thompson, Margret S. [1 ]
Irby, Nita L. [1 ]
Divers, Thomas J. [1 ]
Erb, Hollis N. [2 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Coll Vet Med, Dept Populat Med & Diagnost Sci, Ithaca, NY 14853 USA
关键词
horse; intracranial pressure; optic nerve sheath diameter; ultrasonography; INCREASED INTRACRANIAL-PRESSURE; SEVERE BRAIN-INJURY; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; ULTRASOUND;
D O I
10.1111/vru.12300
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Early diagnosis of high intracranial pressure (ICP) is critical for minimizing progressive brain injury due to reduced cerebral perfusion. In people, detecting enlargement of the optic nerve sheath diameter (ONSD) by transpalpebral ultrasonography has been found to be an accurate test for high ICP. Aims of this prospective, observational, cross-sectional study were to test hypotheses that (1) ultrasonographic measurement of ONSD would be repeatable in horses, (2) have acceptable interobserver agreement, and (3) would be correlated with age and body weight. The sample population included 48 horses without clinical signs of high ICP and with varying ages and body weights. Two observers independently performed ONSD measurements in both eyes. All measurements ranged from 2.6 to 6.5 mm. The mean difference of repeated measures within observers was <= 0.1 mm and the coefficients of variation ranged from 5.0% to 8.8%. The mean difference of measures between observers was <= 0.2 mm. After correcting for performing multiple tests, no significant rank correlation (all r < 0.4 [absolute value]) was detected between ONSD and age or body weight. However, we observed smaller ONSD in foals versus adults (all P <= 0.002). In the foals, all observed measures of rostrocaudal and dorsoventral ONSD were < 5 mm. In the adults, all observed measures of rostrocaudal and dorsoventral ONSD were <= 6.5 mm. Findings indicated that ultrasonographic ONSD measurement is a feasible test for use in horses of varying ages and sizes. Further investigation of this ultrasonographic measure as a clinical test for horse with suspected high ICP is warranted. (C) 2015 American College of Veterinary Radiology.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] ULTRASONOGRAPHIC EVALUATION OF OPTIC NERVE SHEATH DIAMETER AMONG HEALTHY CHINESE ADULTS
    Wang, Lijuan
    Feng, Liangshu
    Yao, Yan
    Deng, Fang
    Wang, Yuzhi
    Feng, Jiachun
    Xing, Yingqi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (03): : 683 - 688
  • [2] Ultrasonographic measurement of the optic nerve sheath diameter in dysthyroid optic neuropathy
    Ji, Xian
    Xiao, Wei
    Ye, Huijing
    Chen, Rongxin
    Wu, Jinghong
    Mao, Yuxiang
    Yang, Huasheng
    EYE, 2021, 35 (02) : 568 - 574
  • [3] Ultrasonographic measurement of the optic nerve sheath diameter in dysthyroid optic neuropathy
    Xian Ji
    Wei Xiao
    Huijing Ye
    Rongxin Chen
    Jinghong Wu
    Yuxiang Mao
    Huasheng Yang
    Eye, 2021, 35 : 568 - 574
  • [4] Transorbital Ultrasonographic Measurement of the Optic Nerve Sheath Diameter in Preeclampsia
    Ferro, Felipe
    Rocha, Edilberto
    Nobrega, Leandro
    Amorim, Melania M.
    Katz, Leila
    OBSTETRICS AND GYNECOLOGY, 2016, 127 : 87S - 87S
  • [5] The measurement of ultrasonographic optic nerve sheath diameter in patients with hyperglycemia
    Donertas, Eda
    Kozaci, Nalan
    Avci, Mustafa
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2022, 29 (03) : 137 - 143
  • [6] Ultrasonographic Optic Nerve Sheath Diameter Technical Pitfalls and Imaging Artifacts
    Hirzallah, Mohammad I.
    Sarwal, Aarti
    Dentinger, Aaron M.
    Robba, Chiara
    Valaikiene, Jurgita
    Lochner, Piergiorgio
    Schlachetzki, Felix
    Mills, David M.
    Ertl, Michael
    Hakimi, Ryan
    Bhise, Shreya
    Pansell, Jakob
    JOURNAL OF ULTRASOUND IN MEDICINE, 2025,
  • [7] Study of the effect of anaesthesia on the canine ultrasonographic optic nerve sheath diameter
    Drolet, C.
    Pinard, C.
    Gaitero, L.
    Monteith, G.
    Bateman, S.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2021, 62 (12) : 1070 - 1078
  • [8] Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review
    Escamilla-Ocanas, Cesar E.
    Morales-Cardona, Noelia C.
    Sagreiya, Hersh
    Akhbardeh, Alireza
    Hirzallah, Mohammad I.
    JOURNAL OF NEUROIMAGING, 2025, 35 (01)
  • [9] Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension
    Li-juan Wang
    Zhang, Ying
    Li, Cong
    Liu, Ying
    Ya-nan Dong
    Cui, Li
    Ying-qi Xin
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2022, 15
  • [10] Transpalpebral ultrasonographic measurement of the optic nerve sheath diameter in healthy dogs
    Smith, Joshua J.
    Fletcher, Daniel J.
    Cooley, Stacy D.
    Thompson, Margret S.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (01) : 31 - 38