Management of arterial injuries caused by laser extraction of indwelling venous pacemaker and defibrillator leads

被引:13
|
作者
Lawton, Jennifer S.
Moon, Marc R.
Curci, John A.
Rubin, Brian G.
Smith, Timothy W.
Gleva, Marye J.
Damiano, Ralph J., Jr.
机构
[1] Washington Univ, Sch Med, Div Cardiothorac Surg, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Med, Div Cardiovasc, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Dept Surg, Div Vasc Surg, St Louis, MO 63110 USA
来源
关键词
pacing; defibrillation-ICD; electrophysiologyclinical;
D O I
10.1111/j.1540-8159.2006.00461.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of laser technology for the removal of pacemaker and defibrillator leads has decreased the lead extraction time and improved the success rate for complete lead removal when compared to traditional techniques. However, this extraction method may be associated with significant complications. This report documents two cases of iatrogenic arteriovenous fistula created by laser lead extraction. Endovascular repair of these fistulas provides an effective and less invasive alternative to open repair.
引用
收藏
页码:917 / 920
页数:4
相关论文
共 50 条
  • [21] Brachial Plexus Injury Caused by Indwelling Axillary Venous Pacing Leads
    Kim, So Yeon
    Park, Jong Sung
    Bang, Jung Hee
    Kang, Eun Ju
    KOREAN CIRCULATION JOURNAL, 2015, 45 (05) : 428 - 431
  • [22] SAFETY AND EFFICACY OF TRANSVENOUS EXTRACTION OF PACEMAKER AND CARDIOVERTER-DEFIBRILLATOR LEADS
    Vefali, H.
    Durkin, M.
    Singh, A.
    Agrawal, S.
    Nanda, S.
    Traub, D.
    Shirani, J.
    CARDIOLOGY, 2016, 134 : 331 - 331
  • [23] Transvenous Extraction of Pacemaker and Defibrillator Leads and the Risk of Tricuspid Valve Regurgitation Making a Case for Thoughtful Lead Management
    Birgersdotter-Green, Ulrika
    Dawood, Farah Z.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (11) : 1429 - 1430
  • [24] Initial experience using Excimer laser for the extraction of chronically implanted pacemaker and implantable cardioverter defibrillator leads in Japanese patients
    Okamura, Hideo
    Yasuda, Satoshi
    Sato, Shunsuke
    Ogawa, Koji
    Nakajima, Ikutaro
    Noda, Takashi
    Shimahara, Yusuke
    Hayashi, Teruyuki
    Onishi, Yoshihiko
    Kobayashi, Junjiro
    Kamakura, Shiro
    Ogawa, Hisao
    Shimizu, Wataru
    JOURNAL OF CARDIOLOGY, 2013, 62 (3-4) : 195 - 200
  • [25] Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools
    Bracke, F
    Meijer, A
    Van Gelder, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07): : 1037 - 1040
  • [26] Predictors and outcomes of patients requiring repeat transvenous lead extraction of pacemaker and defibrillator leads
    Claridge, Simon
    Johnson, Jonathan
    Sadnan, Gazi
    Behar, Jonathan M.
    Porter, Bradley
    Sieniewicz, Benjamin
    Jackson, Tom
    Webb, Jessica
    Gould, Justin
    Sohal, Manav
    Hamid, Shoaib
    Patel, Nik
    Gill, Jaswinder
    Rinaldi, Christopher A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (02): : 155 - 160
  • [27] Excimer laser for pacemaker and defibrillator lead extraction: Techniques and clinical results
    Gilligan, DM
    Dan, D
    LASERS IN MEDICAL SCIENCE, 2001, 16 (02) : 113 - 121
  • [28] Extraction of cardiac rhythm devices: indications, techniques and outcomes for the removal of pacemaker and defibrillator leads
    Farooqi, F. M.
    Talsania, S.
    Hamid, S.
    Rinaldi, C. A.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2010, 64 (08) : 1140 - 1147
  • [29] Excimer Laser for Pacemaker and Defibrillator Lead Extraction: Techniques and Clinical Results
    D.M. Gilligan
    D. Dan
    Lasers in Medical Science, 2001, 16 : 113 - 121
  • [30] Feasibility and safety of the extraction of the pacemaker and defibrillator leads in patients after cardiac transplantation.
    Padder, T
    Hafeez, A
    Abdullah, B
    Padder, F
    Kantharial, B
    Kutalek, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 69H - 69H