Laser switch for stroboscopic read-out of magnetic flux

被引:0
|
作者
Ferrara, M [1 ]
Carelli, P
Chiarello, F
Castellano, MG
Torrioli, G
Cosmelli, C
机构
[1] Univ Aquila, I-67040 Laquila, Italy
[2] INFM, I-67040 Laquila, Italy
[3] CNR, IFN, Ist Foton & Nanotecnol, Rome, Italy
[4] Univ Roma La Sapienza, Rome, Italy
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 06期
关键词
D O I
10.1063/1.1755440
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have realized and tested a fast stroboscopic detector for magnetic flux measurements. The key element of our detector is a hysteretic dc superconducting quantum interference device (SQUID). Stroboscopic read-out of the magnetic flux coupled with the SQUID is accomplished by biasing the SQUID with fast current pulses. The shorter these pulses, the more stroboscopic and less invasive the measurement we are performing. In order to reduce the duration of the current pulses, we take advantage of the superconducting-normal transition induced by laser light in thin superconducting films. The interaction of laser light with superconducting thin films has been investigated thoroughly in the past and many applications have been proposed which rely on the fast typical times with which superconductivity is broken and a resistive behavior arises. We have measured a threshold resolution of 6.9mPhi(0) at 4.2 K, and this value corresponds to the thermodynamic limit of the SQUID. The detector has been accurately characterized: An improved and more sensitive version might prove useful for quantum mechanics and quantum computation experiments, for example, in detecting the state of flux qubits. (C) 2004 American Institute of Physics.
引用
收藏
页码:2116 / 2121
页数:6
相关论文
共 50 条
  • [21] A Lorentz Force Actuated Magnetic Field Sensor with Capacitive Read-Out
    Stifter, M.
    Steiner, H.
    Kainz, A.
    Keplinger, F.
    Hortschitz, W.
    Sauter, T.
    SMART SENSORS, ACTUATORS, AND MEMS VI, 2013, 8763
  • [22] READ-WRITE NONDESTRUCTIVE READ-OUT MEMORY
    WILEY, DL
    PIERCE, RD
    IEEE TRANSACTIONS ON COMMUNICATION AND ELECTRONICS, 1964, 83 (73): : 378 - &
  • [23] MAGNETIC READ-OUT HEAD USING INDUCED RF PERMEABILITY VARIATION
    AKIYAMA, J
    IWASAKI, H
    YATABE, S
    CHIBA, S
    IEEE TRANSACTIONS ON MAGNETICS, 1986, 22 (05) : 692 - 694
  • [24] SIMPLE CAPACITOR READ-OUT FOR WIRE SPARK CHAMBERS IN MAGNETIC FIELDS
    PIZER, HI
    NUCLEAR INSTRUMENTS & METHODS, 1971, 93 (02): : 249 - &
  • [25] Nonvolatile read-out molecular memory
    Liang, YC
    Dvornikov, AS
    Rentzepis, PM
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (14) : 8109 - 8112
  • [26] FAST READ-OUT CHRONOTRON SYSTEM
    MEUNIER, R
    DAVIDSON, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (12): : 1010 - 1015
  • [27] DIFFERENTIAL REFRACTOMETER, WITH DIGITAL READ-OUT
    CORNO, J
    SIMON, J
    AUTOMATISME, 1970, 15 (11): : 594 - &
  • [28] A PLASTICS MICRONITROMETER WITH DIGITAL READ-OUT
    WATT, PR
    CHEMISTRY & INDUSTRY, 1966, (27) : 1166 - &
  • [29] A VERSATILE SCALER AND READ-OUT SYSTEM
    JACKSON, HG
    ROBINSON, LB
    WIEBER, DL
    NUCLEAR INSTRUMENTS & METHODS, 1964, 30 (02): : 261 - 267
  • [30] Read-out ASIC for microstrip detectors
    Atkin E.V.
    Klyuev A.D.
    Silaev A.S.
    Shumikhin V.V.
    Voronin A.G.
    Kudryuashov I.A.
    Podorozhnyi D.M.
    Fedenko A.Y.
    Russian Microelectronics, 2011, 40 (1) : 52 - 58