Comparison of analytical methods based on SPE and SPME techniques for the determination of antifouling booster biocides in natural waters

被引:0
|
作者
Konstantinou, IK [1 ]
Hela, DG [1 ]
Lambropoulou, DA [1 ]
Sakkas, VA [1 ]
Albanis, TA [1 ]
机构
[1] Univ Ioannina, Dept Chem, GR-45110 Ioannina, Greece
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The comparison of analytical procedures, based on solid phase extraction (SPE) and solid phase microextraction (SPME) techniques, for the determination of five organic booster biocides (Irgarol, Dichlofluanid, Chlorothalonil, Folpet, SeaNine 211/Kathon), which are used in marine antifouling paints, is described. Analysis was performed with SDB (styrene-polydivinylbenzene), C18 (octadecyl-silica) and AC (activated carbon) disks used in off-line SPE procedure as well as PDMS (polydimethylsiloxane) and PA (polyacrylate) coating fibres used for the SPME technique, coupled with gas chromatography with electron capture, flame thermionic and mass spectrometric detection. Recovery studies were performed at 0.5-10 mug/l concentration level in spiking water samples of different origin (distilled, lake, river and sea water) after optimization of each technique. Irgarol, Sea Nine and chlorothalonil were extracted effectively with C18 and SDB disks (recovery >75%), while dichlofluanid was moderately or insufficiently extracted (recovery less than or equal to65%). With CB disks carefully extraction procedure is needed for the efficient extraction of dichlofluanid, Sea Nine and Irgarol, while chlorothalonil was difficult to be desorbed (recovery less than or equal to60%). In SPME procedure both fibres were capable to extract all biocides showing recoveries in relatively high levels (65-124,4%). SPME can be used more efficiently as a multiresidue technique for the tested biocides than SPE which requires the use of different sorbents for the determination of biocides. Very low limits of detection (1-60 ng/l) can be achieved under the optimized conditions with both SPE and SPME techniques and thus, their potential of trace-level screening determination of antifouling biocides in natural waters is demonstrated.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 44 条
  • [41] Comparison of analytical methodologies based on 1H and 31P NMR spectroscopy with conventional methods of analysis for the determination of some olive oil constituents
    Dais, Photis
    Spyros, Apostolos
    Christophoridou, Stella
    Hatzakis, Emmanuel
    Fragaki, Georgia
    Agiomyrgianaki, Alexia
    Salivaras, Emmanuel
    Siragakis, George
    Daskalaki, Despina
    Tasioula-Margari, Maria
    Brenes, Manuel
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (03) : 577 - 584
  • [42] Comparison of atomic absorption, mass and X-ray spectrometry techniques using dissolution-based and solid sampling methods for the determination of silver in polymeric samples
    De Schrijver, Isabel
    Aramendia, Maite
    Vincze, Laszlo
    Resano, Martin
    Dumoulin, Ann
    Vanhaecke, Frank
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (11) : 1185 - 1194
  • [43] Use of an ether-derived 3-hydroxy-4-pyridinone chelator as a new chromogenic reagent in the development of a microfluidic paper-based analytical device for Fe(III) determination in natural waters
    Moniz, Tania
    Bassett, Chelsea R.
    Almeida, M. Ines G. S.
    Kolev, Spas D.
    Rangel, Maria
    Mesquita, Raquel B. R.
    TALANTA, 2020, 214
  • [44] Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells
    Yang, Ting
    Xu, Feifei
    Xu, Jinhui
    Fang, Danjun
    Yu, Ying
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 936 : 18 - 24