Comparison of liquid chromatography-tandem mass spectrometry-based targeted proteomics and conventional analytical methods for the determination of P-glycoprotein in human breast cancer cells

被引:16
|
作者
Yang, Ting [1 ]
Xu, Feifei [1 ]
Xu, Jinhui [1 ]
Fang, Danjun [1 ]
Yu, Ying [1 ]
Chen, Yun [1 ]
机构
[1] Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
P-glycoprotein; Liquid chromatography-tandem mass spectrometry; Targeted proteomics; Stable isotope labeling; Methods comparison; RESISTANCE-ASSOCIATED PROTEIN-2; MULTIDRUG-RESISTANCE; ABSOLUTE QUANTIFICATION; MEMBRANE-PROTEINS; TRANSPORTER; RESIDUES;
D O I
10.1016/j.jchromb.2013.07.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
P-glycoprotein (P-gp) is the most frequently proposed factor for multi-drug resistance. It is traditionally measured using antibody-based methods. While these techniques can provide relative quantification values for P-gp levels, the important information that is usually missing is its amount in the biological system. In this study, a novel and advanced liquid chromatography-tandem mass spectrometry (LC/MS/MS)-based targeted proteomics assay was developed and validated for the determination of P-gp in the breast cancer drug sensitive cell line MCF-7/WT and the drug resistant cell line MCF-7/ADR. Three tryptic peptides (434STTVQLMQR442, 674GSQAQDR680 and 368IIDNKPSIDSYSK380) can specifically represent P-gp. Among these peptides, 434STTVQLMQR442 was selected as the surrogate analyte for quantification, and a stable isotope-labeled synthetic peptide with the same sequence was used as an internal standard. The calibration range was validated from 10 to 1000 ng/mL. The intra- and inter-day precisions were within 5.9% and 3.7%, respectively. The accuracy for the quality control (QC) samples was within 8.0%. Using this assay, the amounts of P-gp were accurately quantified as 3.53 fg/cell (similar to 2.08 x 10(-2) amol/cell) in the MCF-7/WT cells and 34.5 fg/cell (similar to 2.02 x 10(-1) amol/cell) in the MCF-7/ADR cells. This outcome was then compared with those obtained by conventional analytical methods including confocal microscopy, western blotting and flow cytometry. The comparative results show that not only is the LC/MS/MS-based targeted proteomics assay able to monitor the protein levels in a more accurate manner, but the large discrepancy observed between the other methods was most likely due to the lack of specificity and the semi-quantitative nature of the conventional assays (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [1] A liquid chromatography-tandem mass spectrometry-based targeted proteomics assay for monitoring P-glycoprotein levels in human breast tissue
    Yang, Ting
    Chen, Fei
    Xu, Feifei
    Wang, Fengliang
    Xu, Qingqing
    Chen, Yun
    [J]. CLINICA CHIMICA ACTA, 2014, 436 : 283 - 289
  • [2] An investigation of heat shock protein 27 and P-glycoprotein mediated multi-drug resistance in breast cancer using liquid chromatography-tandem mass spectrometry-based targeted proteomics
    Xu, Feifei
    Yang, Ting
    Fang, Danjun
    Xu, Qingqing
    Chen, Yun
    [J]. JOURNAL OF PROTEOMICS, 2014, 108 : 188 - 197
  • [3] A liquid chromatography-tandem mass spectrometry-based targeted proteomics approach for the assessment of transferrin receptor levels in breast cancer
    Yang, Ting
    Xu, Feifei
    Zhao, Yi
    Wang, Shui
    Yang, Mi
    Chen, Yun
    [J]. PROTEOMICS CLINICAL APPLICATIONS, 2014, 8 (9-10) : 773 - 782
  • [4] Liquid chromatography/tandem mass spectrometry based targeted proteomics quantification of P-glycoprotein in various biological samples
    Zhang, Yiqun
    Li, Na
    Brown, Paul W.
    Ozer, Josef S.
    Lai, Yurong
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (12) : 1715 - 1724
  • [5] Quantification of human serum transferrin using liquid chromatography-tandem mass spectrometry based targeted proteomics
    Yu, Ying
    Xu, Jinhui
    Liu, Yuan
    Chen, Yun
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 902 : 10 - 15
  • [6] Simultaneous determination of the flavonoids robinin and kaempferol in human breast cancer cells by liquid chromatography-tandem mass spectrometry
    Tsiklauri, Lia
    An, Guohua
    Ruszaj, Donna M.
    Alaniya, Mary
    Kemertelidze, Ether
    Morris, Marilyn E.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (01) : 109 - 113
  • [7] Quantification of microRNA by DNA-Peptide Probe and Liquid Chromatography-Tandem Mass Spectrometry-Based Quasi-Targeted Proteomics
    Xu, Feifei
    Yang, Ting
    Chen, Yun
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (01) : 754 - 763
  • [8] Liquid chromatography-tandem mass spectrometry-based fragmentation analysis of glycopeptides
    Jonas Nilsson
    [J]. Glycoconjugate Journal, 2016, 33 : 261 - 272
  • [9] Liquid chromatography-tandem mass spectrometry-based fragmentation analysis of glycopeptides
    Nilsson, Jonas
    [J]. GLYCOCONJUGATE JOURNAL, 2016, 33 (03) : 261 - 272
  • [10] Development of liquid chromatography-tandem mass spectrometry-based analytical assays for the determination of HIF stabilizers in preventive doping research
    Beuck, Simon
    Bornatsch, Wolfgang
    Lagojda, Andreas
    Schaenzer, Wilhelm
    Thevis, Mario
    [J]. DRUG TESTING AND ANALYSIS, 2011, 3 (11-12) : 756 - 770