BIO-IMPEDANCE MEASUREMENT ALLOWS DISPLAYING THE EARLY STAGES OF NEUTROPHIL EXTRACELLULAR TRAPS

被引:9
|
作者
Linnemann, Caren [1 ]
Venturelli, Sascha [2 ,3 ]
Konrad, Franziska [4 ]
Nussler, Andreas K. [1 ]
Ehnert, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Siegfried Weller Inst Trauma Res, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Inst Physiol, Dept Vegetat & Clin Physiol, Tubingen, Germany
[3] Univ Hohenheim, Inst Nutr Sci, Dept Nutr Biochem, Stuttgart, Germany
[4] Univ Hosp Tuebingen, Dept Anesthesiol & Intens Care Med, Tubingen, Germany
来源
EXCLI JOURNAL | 2020年 / 19卷
关键词
Bio-impedance; neutrophils; neutrophil extracellular traps; Sytox Green Assay; xCelligence; immune cell activation; NADPH OXIDASE; DYNAMICS; VIABILITY; PROMOTE; ASSAY;
D O I
10.17179/excli2020-2868
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Neutrophils are the most abundant immune cells in the blood. Besides common immune defense mechanisms, releasing their DNA covered with antimicrobial proteases and histones represent another strong defense mechanism: neutrophil extracellular traps. In vitro the two most common inducers of these, so called, NETs are calcium ionophores (CI) and PMA (Phorbol 12-myristate 13-acetate). Following stimulation monitoring of NET release is necessary. For now, the methods of choice are quantification of free DNA by fluorescent dyes or analysis of immunofluorescence images. As a new method we tested bio-impedance monitoring of neutrophils after stimulation with the two inducers PMA and CI in gold-electrode coated plates. Bio-impedance (cell index) was measured over time. Results were compared to the monitoring of NETs by the fluorescent DNA-binding dye Sytox Green and immunofluorescence analysis. Cell index peaked about 25 min faster following CI stimulation than following PMA stimulation. The activation in Sytox Green Assay was significantly later detectable for PMA (+ approx. 90 min) but not for CI stimulation. The earlier and faster activation by CI was also confirmed by immunofluorescence staining Our data suggest that bio-impedance measurement allows an easy online tracking of early neutrophil activation. This offers new opportunities to monitor early phases and stimuli-dependent dynamics of NETosis.
引用
收藏
页码:1481 / 1495
页数:15
相关论文
共 50 条
  • [1] Adaptive Bio-impedance Measurement
    Favalli, A.
    Tavilla, A. C.
    Robortella, R.
    Stefanini, I
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [2] A CMOS Bio-Impedance Measurement System
    Yufera, Alberto
    Rueda, Adoracion
    PROCEEDINGS OF THE 2009 IEEE SYMPOSIUM ON DESIGN AND DIAGNOSTICS OF ELECTRONIC CIRCUITS AND SYSTEMS, 2009, : 252 - 257
  • [3] Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysis
    Lingwood, BE
    Coghlan, JP
    Ward, LC
    Charles, BG
    Colditz, PB
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) : 251 - 262
  • [4] Lock-in measurement of bio-impedance variations
    Min, M
    Märtens, O
    Parve, T
    MEASUREMENT, 2000, 27 (01) : 21 - 28
  • [5] Multifrequency bio-impedance measurement:: undersampling approach
    Märtens, O
    Min, M
    NORSIG 2004: PROCEEDINGS OF THE 6TH NORDIC SIGNAL PROCESSING SYMPOSIUM, 2004, 46 : 145 - 148
  • [6] The Impedance Property of Electrode Used in Electrical Bio-impedance Measurement
    Gong WeiYan
    Lv JingHua
    Wang Yan
    Sha Hong
    Zhao Shu
    Ren ChaoShi
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2308 - +
  • [7] A Bio-Impedance Measurement IC for Neural Interface Applications
    Munge, Ajinkya
    Sankar, Varsha
    Sendi, Mohammad S. E.
    Ghovanloo, Maysam
    Guler, Ulkuhan
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 271 - 274
  • [8] A Virtual Instrument for Bio-impedance Measurement in Oral Cavity
    Kastelan, M.
    Vlahinic, S.
    Richter, I.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1133 - 1136
  • [9] Continuous measurement of segmental and whole body bio-impedance
    Zhu, FS
    Schneditz, D
    Wang, EJ
    Levin, NW
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2086 - 2088
  • [10] Study of the bio-impedance measurement system and extraction of the impedance characteristic parameters
    Ma, Lan
    Yang, Yu-Xing
    Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2002, 15 (03):