BIO-IMPEDANCE MEASUREMENT ALLOWS DISPLAYING THE EARLY STAGES OF NEUTROPHIL EXTRACELLULAR TRAPS

被引:9
|
作者
Linnemann, Caren [1 ]
Venturelli, Sascha [2 ,3 ]
Konrad, Franziska [4 ]
Nussler, Andreas K. [1 ]
Ehnert, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Siegfried Weller Inst Trauma Res, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Inst Physiol, Dept Vegetat & Clin Physiol, Tubingen, Germany
[3] Univ Hohenheim, Inst Nutr Sci, Dept Nutr Biochem, Stuttgart, Germany
[4] Univ Hosp Tuebingen, Dept Anesthesiol & Intens Care Med, Tubingen, Germany
来源
EXCLI JOURNAL | 2020年 / 19卷
关键词
Bio-impedance; neutrophils; neutrophil extracellular traps; Sytox Green Assay; xCelligence; immune cell activation; NADPH OXIDASE; DYNAMICS; VIABILITY; PROMOTE; ASSAY;
D O I
10.17179/excli2020-2868
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Neutrophils are the most abundant immune cells in the blood. Besides common immune defense mechanisms, releasing their DNA covered with antimicrobial proteases and histones represent another strong defense mechanism: neutrophil extracellular traps. In vitro the two most common inducers of these, so called, NETs are calcium ionophores (CI) and PMA (Phorbol 12-myristate 13-acetate). Following stimulation monitoring of NET release is necessary. For now, the methods of choice are quantification of free DNA by fluorescent dyes or analysis of immunofluorescence images. As a new method we tested bio-impedance monitoring of neutrophils after stimulation with the two inducers PMA and CI in gold-electrode coated plates. Bio-impedance (cell index) was measured over time. Results were compared to the monitoring of NETs by the fluorescent DNA-binding dye Sytox Green and immunofluorescence analysis. Cell index peaked about 25 min faster following CI stimulation than following PMA stimulation. The activation in Sytox Green Assay was significantly later detectable for PMA (+ approx. 90 min) but not for CI stimulation. The earlier and faster activation by CI was also confirmed by immunofluorescence staining Our data suggest that bio-impedance measurement allows an easy online tracking of early neutrophil activation. This offers new opportunities to monitor early phases and stimuli-dependent dynamics of NETosis.
引用
收藏
页码:1481 / 1495
页数:15
相关论文
共 50 条
  • [11] Lower Leg Edema Assessment from Bio-Impedance Measurement
    Wang, Guangjing
    Zhao, Xingqun
    Yu, Conglong
    2014 INTERNATIONAL CONFERENCE ON BIOLOGICAL ENGINEERING AND BIOMEDICAL (BEAB 2014), 2014, : 288 - 293
  • [12] Micro-electrodes for in situ temperature and bio-impedance measurement
    Leung, Timothy Ka Wai
    Ji, Xudong
    Peng, Boyu
    Chik, Gary Kwok Ki
    Dai, Derek Shui Hong Siddhartha
    Fang, Ge
    Zhang, Tengfei
    Cheng, Xing
    Kwok, Ka Wai
    Tsang, Anderson Chun On
    Leung, Gilberto Ka Kit
    Chan, Paddy Kwok Leung
    NANO SELECT, 2021, 2 (10): : 1986 - 1996
  • [13] An endonuclease allows Streptococcus pneumoniae to escape from neutrophil extracellular traps
    Beiter, K
    Wartha, F
    Albiger, B
    Normark, S
    Zychlinsky, A
    Henriques-Normark, B
    CURRENT BIOLOGY, 2006, 16 (04) : 401 - 407
  • [14] Bio-Impedance Spectroscopy (BIS) Measurement System for Wearable Devices
    Ibrahim, Bassem
    Hall, Drew A.
    Jafari, Roozbeh
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [15] Neutrophil Extracellular Traps Associate with Clinical Stages in Breast Cancer
    Rivera-Franco, Monica M.
    Leon-Rodriguez, Eucario
    Torres-Ruiz, Jose J.
    Gomez-Martin, Diana
    Angles-Cano, Eduardo
    de la Luz Sevilla-Gonzalez, Maria
    PATHOLOGY & ONCOLOGY RESEARCH, 2020, 26 (03) : 1781 - 1785
  • [16] Method and device for bio-impedance measurement with hard-tissue applications
    Guimera, A.
    Calderon, E.
    Los, P.
    Christie, A. M.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (06) : S279 - S290
  • [17] Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy
    Turner, AA
    Lozano-Nieto, A
    Bouffard, M
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (04) : 385 - 397
  • [18] Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement
    Wang, Ting-Wei
    Syu, Jhen-Yang
    Chu, Hsiao-Wei
    Sung, Yen-Ling
    Chou, Lin
    Escott, Endian
    Escott, Olivia
    Lin, Ting-Tse
    Lin, Shien-Fong
    Biosensors, 2022, 12 (03):
  • [19] Measurement of bio-impedance characteristic of freshwater fish based on virtual instrument
    Huazhong Agricultural University, Wuhan 430070, China
    Nongye Jixie Xuebao, 2007, 9 (103-107):
  • [20] A High Frequency Read-Out Channel for Bio-Impedance Measurement
    Takhti, Mohammad
    Teng, Yueh-Ching
    Odame, Kofi
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 1514 - 1517