Multifrequency bio-impedance measurement:: undersampling approach

被引:0
|
作者
Märtens, O [1 ]
Min, M [1 ]
机构
[1] Tallinn Univ Technol, Dept Elect, EE-19086 Tallinn, Estonia
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
For digital measurement of slowly changing modulation waveforms, e.g. electrical bio-impedance (EBI) variations of several higher frequency carriers simultaneously, the undersampling approach allows to extend the range of carrier frequencies significantly beyond the Nyquist limit, and to reduce the computational power at the same time. Basic equations for choosing of signal and sampling frequencies are found An example solution is proposed, and analyzed by MATLAB simulation for further implementations on some real DSP-platform. In the simulated example, the 1 Hz EBI variation and 15,059 ks/s sampling rate in the case of 4 kHz and 64 kHz carriers were used.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [1] Adaptive Bio-impedance Measurement
    Favalli, A.
    Tavilla, A. C.
    Robortella, R.
    Stefanini, I
    [J]. 2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [2] A CMOS Bio-Impedance Measurement System
    Yufera, Alberto
    Rueda, Adoracion
    [J]. PROCEEDINGS OF THE 2009 IEEE SYMPOSIUM ON DESIGN AND DIAGNOSTICS OF ELECTRONIC CIRCUITS AND SYSTEMS, 2009, : 252 - 257
  • [3] Intercompartmental fluid shifts monitored by multifrequency bio-impedance spectroscopy (BIS).
    Zaluska, WT
    Schneditz, D
    Kaufman, AM
    Morris, AT
    Levin, NW
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0887 - A0887
  • [4] Lock-in measurement of bio-impedance variations
    Min, M
    Märtens, O
    Parve, T
    [J]. MEASUREMENT, 2000, 27 (01) : 21 - 28
  • [5] The Impedance Property of Electrode Used in Electrical Bio-impedance Measurement
    Gong WeiYan
    Lv JingHua
    Wang Yan
    Sha Hong
    Zhao Shu
    Ren ChaoShi
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2308 - +
  • [6] Lack of congruence in single and multifrequency bio-impedance estimates of body composition.
    Howell, W
    Houtkooner, L
    Reid, P
    Greaves, K
    Going, S
    Lohman, T
    [J]. FASEB JOURNAL, 1996, 10 (03): : 1210 - 1210
  • [7] A Bio-Impedance Measurement IC for Neural Interface Applications
    Munge, Ajinkya
    Sankar, Varsha
    Sendi, Mohammad S. E.
    Ghovanloo, Maysam
    Guler, Ulkuhan
    [J]. 2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 271 - 274
  • [8] A Virtual Instrument for Bio-impedance Measurement in Oral Cavity
    Kastelan, M.
    Vlahinic, S.
    Richter, I.
    [J]. 4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1133 - 1136
  • [9] Continuous measurement of segmental and whole body bio-impedance
    Zhu, FS
    Schneditz, D
    Wang, EJ
    Levin, NW
    [J]. PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2086 - 2088
  • [10] Study of the bio-impedance measurement system and extraction of the impedance characteristic parameters
    Ma, Lan
    Yang, Yu-Xing
    [J]. Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2002, 15 (03):