Comparison of patient doses at different CT scanners with same acquisition protocol

被引:0
|
作者
Balkay, L. [1 ]
Oszlanski, A. [1 ]
Krizsan, A. K. [1 ]
机构
[1] Univ Debrecen, Inst Nucl Med, H-4012 Debrecen, Hungary
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the last decade both the number of powerful CT scanners and the number of patient investigations increased with a consequent increase of the patient radiation dose. There are large dose variations (more than 10 fold) among individual CT centers and it remains true if they include the same model of CT scanners. The aim of this study was to compare the patient effective dose (D-e) during the CT examinations from different manufacturer models presuming the same acquisition protocol and using the imPACT patient organ and effective dose calculator program. The following manufacturers and models were selected in the program: GE (LightSpeed Ultra, LightSpeed 16, LightSpeed Pro 16, LightSpeed VCT), Philips (Brilliance 16, Brilliance 16 Power, Big Bore, Brilliance 64/40) and the Siemens (Emotion 6, Sensation 16, Sensation 16 Straton, Sensation 64, Definition AS). Head and body scans were defined for all cases altering tube voltages, while dose calculations were normalized to 100 mAs X-ray exposure. It was found that in body investigations the calculated D-e for the GE scans were higher by 20% comparing to Siemens and Philips related values. For the head examinations the differences were larger by almost 55%. We also demonstrated that a power relationship can be found between the De and the tube voltage with the exponent of 3.02+/-0.14 kV-1 and 2.68+/-0.14 kV-1 for the body and the head scans respectively. It can be concluded that the patient effective dose could be different in CT examinations using distinct CT scanners but defining the same acquisition protocol. Considering the patient dose, this also means that the scan protocols cannot be transferred between different models without specific investigation.
引用
收藏
页码:3644 / 3645
页数:2
相关论文
共 50 条
  • [31] Same same but different: dopamine transporter SPECT on scanners with CZT vs. NaI detectors
    Thiele, Felix
    Schau, Franziska
    Rogasch, Julian M. M.
    Wetz, Christoph
    Bluemel, Stephanie
    Brenner, Winfried
    Amthauer, Holger
    Lange, Catharina
    Schatka, Imke
    EJNMMI RESEARCH, 2023, 13 (01)
  • [32] EFFECTIVE DOSES RADIATION TO THE PATIENTS IN EXAMINATIONS PERFORMED IN THREE CT SCANNERS IN BRAZIL
    Costa Janson Ney, Monica Silva
    Moreira Damas Dos Santos, Alair Augusto Sarmet
    De Souza Fonseca, GIuliana Vasconcelos
    Lodi, Caio Silva
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 444 - 449
  • [33] Dead on arrival: Optimizing CT data acquisition of fossils using modern hospital CT scanners
    Ridgely, Ryan
    Witmer, Lawrence
    JOURNAL OF VERTEBRATE PALEONTOLOGY, 2006, 26 (03) : 115A - 115A
  • [34] Different speakers but same Language Acquisition Device?
    Hulstijn, Jan H.
    LINGUISTIC APPROACHES TO BILINGUALISM, 2012, 2 (03) : 273 - 276
  • [35] Typical patient doses from CT part of PET/CT examinations in Slovenia and comparison with other countries
    Peric, J.
    Zagar, I.
    Zontar, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S864 - S864
  • [36] Managing Pediatric CT Patient Doses
    Strauss, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [37] Comparison between a GnRH Agonist and a GnRH Antagonist Protocol for the Same Patient Undergoing IVF
    Li, Yufeng
    Li, Yuan
    Lai, Qiaohong
    Zhang, Hanwang
    Zhu, Guijin
    Jin, Lei
    Yue, Jing
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2008, 28 (05) : 618 - 620
  • [38] Comparison between a GnRH agonist and a GnRH antagonist protocol for the same patient undergoing IVF
    Yufeng Li
    Yuan Li
    Qiaohong Lai
    Hanwang Zhang
    Guijin Zhu
    Lei Jin
    Jing Yue
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2008, 28 : 618 - 620
  • [39] PATIENT RADIATION DOSES IN CARDIAC COMPUTED TOMOGRAPHY: COMPARISON OF PUBLISHED RESULTS WITH PROSPECTIVE AND RETROSPECTIVE ACQUISITION
    Efstathopoulos, E. P.
    Pantos, I.
    Thalassinou, S.
    Argentos, S.
    Kelekis, N. L.
    Zografos, T.
    Panayiotakis, G.
    Katritsis, D. G.
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (01) : 83 - 91
  • [40] Doses metrics and patient age in CT
    Huda, Walter
    Tipnis, Sameer V.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (03) : 374 - 380