Comparative in vitro performance of valved holding chambers with a budesonide/formoterol pressurized metered-dose inhaler

被引:7
|
作者
Chambers, Frank E. [1 ]
Brown, Steven [1 ]
Ludzik, Andrew J. [1 ]
机构
[1] AstraZeneca R&D Charnwood, Pharmaceut & Analyt R&D, Loughborough LE11 5RH, Leics, England
关键词
Asthma; budesonide/formoterol; corticosteroid; delivered dose; drug delivery; fine particle dose; long-acting beta(2)-adrenergic agonist; pressurized metered-dose inhaler; tidal breathing pattern; valved holding chamber; ELECTROSTATIC CHARGE; MULTIPLE ACTUATIONS; AEROSOL DELIVERY; PLASTIC SPACERS; DEVICES; BUDESONIDE; FORMOTEROL; EFFICACY; FACEMASK; THERAPY;
D O I
10.2500/aap.2009.30.3252
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
A combination of budesonide and formoterol in a single pressurized metered-dose inhaler (pMDI) is available in the United States and elsewhere. This study was designed to evaluate the delivered dose and fine particle dose (FPD; mass of particles <4.7-micrometer diameter) using the pMDI with two valved holding chambers (VHCs), using sampling methods reflecting different patient techniques. FPD was measured using an Andersen Cascade Impactor and delivered dose was measured using a disposable filter. Two VHCs, AeroChamber Plus and AeroChamber MAX (Trudell Medical International, London, Ontario, Canada), were evaluated using three sampling methods: (1) immediate collection; (2) collection after tip to a 5-second delay, (3) using simulated adult, child, and infant tidal breathing patterns (delivered dose). Decreases in delivered dose were observed using a VHC compared with the pMDI alone. FPD with both VHCs was similar to that with the pMDI alone with minimal delay between actuation and collection. With delays, the antistatic AeroChamber MAX was more resistant than AeroChamber Plus to dose losses. Delivered doses from adult and child profiles were comparable with those after a I-second delay. The infant profile produced lower delivered doses, probably because more breath cycles are required to empty the VHC. Budesonide/formoterol pMDI can be used effectively with AeroChamber Plus and the antistatic AeroChamber MAX. With minimal delay between actuation and collection, FPD with both VHCs was similar to that with the pMDI alone, giving physicians a choice of administration regimen and taking into account the needs and skills of the patient. (Allergy Asthma Proc 30:424-432, 2009; doi: 10.2500/aap.2009.30.3252)
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
  • [21] Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber
    Demirkan, K
    Tolley, E
    Mastin, T
    Soberman, J
    Burbeck, J
    Self, T
    CHEST, 2000, 117 (05) : 1314 - 1318
  • [22] Budesonide/Formoterol Pressurized Metered-Dose Inhaler versus Budesonide: A Randomized Controlled Trial in Black Patients with Asthma
    Spector, Sheldon L.
    Martin, Ubaldo J.
    Uryniak, Tom
    O'Brien, Christopher D.
    JOURNAL OF ASTHMA, 2012, 49 (01) : 70 - 77
  • [23] Valved Holding Chambers and In Vitro Metered Dose Inhaler Performance: Effects of Flow Rate and Inhalation Delay
    Liu, Xiaofei
    Guo, Changning
    Chowdhury, Badrul
    Starke, Peter
    Limb, Susan
    Peri, Prasad
    Schroeder, Alan
    Doub, William
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (06) : 399 - 410
  • [24] Pharmacokinetics of Budesonide and Formoterol Administered Via 1 Pressurized Metered-Dose Inhaler in Patients With Asthma and COPD
    Tronde, Ann
    Gillen, Michael
    Borgstrom, Lars
    Lotvall, Jan
    Ankerst, Jaro
    JOURNAL OF CLINICAL PHARMACOLOGY, 2008, 48 (11): : 1300 - 1308
  • [26] A Valved Holding Chamber Does Not Decrease the Bronchodilator Activity of Budesonide-Formoterol Combination Metered Dose Inhaler
    Mansfield, Lyndon E.
    Maynes, Ruby
    JOURNAL OF ASTHMA, 2013, 50 (01) : 71 - 74
  • [27] ASSESSING DIFFERENT VALVED HOLDING CHAMBERS (VHC) WITH FACEMASK FOR DELIVERED MASS TO CARINA WITH INHALED CORTICOSTEROID BY PRESSURIZED METERED-DOSE INHALER (PMDI)
    Suggett, J.
    Nagel, M.
    Bracey, A.
    THORAX, 2018, 73 : A262 - A263
  • [28] Evaluation of Valved Holding Chambers Simulating Repurposing Use of Ciclesonide Metered-dose Inhaler by Patients with Pneumonia
    Yoshida, Hiroyuki
    Abe, Yasuhiro
    Usui, Akiko
    Izutsu, Ken-ichi
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2020, 140 (12): : 1495 - 1500
  • [29] Formoterol/budesonide pressurized metered-dose inhaler: A guide to its use in chronic obstructive pulmonary disease
    Lyseng-Williamson K.A.
    Drugs & Therapy Perspectives, 2014, 30 (8) : 269 - 275
  • [30] How to Compare Two Different Metered-Dose Inhaler-Valved Holding Chambers in the Administration of Salbutamol
    Garcia-Arieta, Alfredo
    CHEST, 2010, 138 (03) : 758 - 759