Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber

被引:18
|
作者
Demirkan, K
Tolley, E
Mastin, T
Soberman, J
Burbeck, J
Self, T [1 ]
机构
[1] Univ Tennessee, Ctr Hlth Sci, Dept Clin Pharm, Memphis, TN 38163 USA
[2] Univ Tennessee, Dept Biostat & Epidemiol, Memphis, TN 38163 USA
[3] Univ Tennessee, Dept Med, Div Pulm & Crit Care Med, Memphis, TN 38163 USA
[4] Univ Tennessee, Dept Med, Div Cardiol, Memphis, TN 38163 USA
关键词
asthma; metered-dose inhaler; salmeterol; spacer device;
D O I
10.1378/chest.117.5.1314
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine whether a spacer device designed as a valved holding chamber with a flow signal increases the efficacy of the long-acting beta(2)-agonist, salmeterol, in patients who use incorrect technique with metered-dose inhaler (MDI) alone. Design: Double-blind, randomized, placebo-controlled study. Setting: University hospital outpatient rooms. Patients: Twenty adult outpatients with stable persistent asthma, receiving a daily anti-inflammatory drug. Interventions: Patients were randomized to either salmeterol MDI (incorrect use: 1 s after actuating MDI, inhale rapidly) and placebo plus spacer (correct use: inhale slowly as MDI is actuated, continue to inhale slowly and deeply) or placebo MDI (incorrect use) and salmeterol plus spacer (correct use). The following week, patients received the opposite treatment. The dose was two puffs from each device on each treatment day; each puff was separated by 1 min. Measurements and results: After baseline peak expiratory flow (PEF), salmeterol was administered and serial PEF determined (0.5, 1, 2, 3, 4, 6, 8, 10, and 12 h). Administration of salmeterol MDI plus spacer resulted in significantly greater increases in PEF from baseline vs MDI at 4 h (44 L/min ra 10 L/min; p < 0.01) and 6 h (49 L/min vs 24 L/min; p < 0.05). Both methods of administration were equally well tolerated. Conclusion: We conclude that patients who have poor timing and rapid inhalation with salmeterol MDI alone will have greater increases in PEF at 4 h and 8 h and no additional side effects if the dose is administered with a valved holding chamber that is used correctly. Further study is needed regarding other errors in MDI technique with salmeterol.
引用
收藏
页码:1314 / 1318
页数:5
相关论文
共 50 条
  • [1] Automatic replacement of albuterol nebulizer therapy by metered-dose inhaler and valved holding chamber
    Hendeles, L
    Hatton, RC
    Coons, TJ
    Carlson, L
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (10) : 1053 - 1061
  • [2] In vitro performance characteristics of valved holding chamber and spacer devices with a fluticasone metered-dose inhaler
    Asmus, MJ
    Liang, J
    Coowanitwong, I
    Hochhaus, G
    PHARMACOTHERAPY, 2004, 24 (02): : 159 - 166
  • [3] The effect of a holding chamber on albuterol metered-dose inhaler product differences
    Johnson, Jennifer L. H.
    Guthrie, Danielle
    Hyde, Joel
    Hanson, Thomas
    Karlage, Kelly
    Myrdal, Paul B.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2016, 117 (03) : 246 - 250
  • [4] Comparison of Easyhaler® Metered-Dose, Dry Powder Inhaler and a Pressurised Metered-Dose Inhaler plus Spacer in the Treatment of Asthma in Children
    K. Juntunen-Backman
    M. Kajosaari
    K. Laurikainen
    A. Malinen
    M. Kaila
    L. Mustala
    U. Kaski
    O. Linna
    M. Marenk
    P. Toivanen
    Clinical Drug Investigation, 2002, 22 : 827 - 835
  • [5] Comparison of Easyhaler® metered-dose, dry powder inhaler and a pressurised metered-dose inhaler plus spacer in the treatment of asthma in children
    Juntunen-Backman, K
    Kajosaari, M
    Laurikainen, K
    Malinen, A
    Kaila, M
    Mustala, L
    Kaski, U
    Linna, O
    Marenk, M
    Toivanen, P
    CLINICAL DRUG INVESTIGATION, 2002, 22 (12) : 827 - 835
  • [6] Comparison of AeroChamber and AeroChamber-Plus valved holding chamber in-vitro performance with a fluticasone metered-dose inhaler
    Liang, J
    Asmus, MJ
    Coowanitwong, I
    Hochhaus, G
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2001, 107 (02) : S103 - S103
  • [7] Barriers to metered-dose inhaler plus spacer use
    Levine, SB
    Hyman, E
    Dimaggio, D
    Betances, JA
    Sharif, I
    Ozuah, PO
    JOURNAL OF INVESTIGATIVE MEDICINE, 2003, 51 : S416 - S416
  • [8] Nonprescription Epinephrine Metered-Dose Inhaler: To Be or Not To Be
    Blake, Kathryn
    Raissy, Hengameh
    PEDIATRIC ALLERGY IMMUNOLOGY AND PULMONOLOGY, 2014, 27 (03) : 143 - 146
  • [9] The conversion to metered-dose inhaler with valved holding chamber to administer inhaled albuterol: A pediatric hospital experience
    Salyer, John W.
    DiBlasi, Robert M.
    Crotwell, Dave N.
    Cowan, Charles A.
    Carter, Edward R.
    RESPIRATORY CARE, 2008, 53 (03) : 338 - 345
  • [10] Recommendation for modified metered-dose inhaler
    Ahmed, S
    Gunaratnam, NT
    Patton, WF
    AMERICAN FAMILY PHYSICIAN, 2002, 66 (08) : 1401 - 1401