Control of indoor CO2 concentration based on a process model

被引:12
|
作者
Skrjanc, Igor [2 ]
Subic, Barbara [1 ]
机构
[1] Univ Ljubljana, Fac Civil Engn, Jamova 1000 2, Slovenia
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
Modeling; Internal model control; PREDICTIVE FUNCTIONAL CONTROL; ENERGY-CONSUMPTION; AIR; STRATEGIES; SYSTEM;
D O I
10.1016/j.autcon.2014.02.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-tight buildings need to have ventilation systems, although the use of these systems results in heavy energy consumption within the building sector. For this reason they have to be adequately regulated in order to achieve good indoor air quality and lower operation costs. The main challenge is to optimize regulation in office buildings, theaters, museums, and schools, where there are large fluctuations and heavy operating costs. Each further optimization leads directly to a better indoor climate and a reduction in energy consumption. In the case of ventilation systems. PI or PID regulators are usually used. In the described research an internal model control (IMC) system was designed with an internal loop, which constantly checks the momentary CO2 concentration, and makes the necessary adjustments to the air flow. The results showed a significant improvement in the CO2 level when using an IMC controller, in comparison with PI controller. The desired indoor air quality is achieved more than 80% of the time, with lower operating costs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 126
页数:5
相关论文
共 50 条
  • [31] A comparison of atmospheric CO2 concentration GOSAT-based observations and model simulations
    Lei LiPing
    Guan XianHua
    Zeng ZhaoCheng
    Zhang Bing
    Ru Fei
    Bu Ran
    SCIENCE CHINA-EARTH SCIENCES, 2014, 57 (06) : 1393 - 1402
  • [32] Research on the measurement of CO2 concentration based on multi-band fusion model
    Li, Honglian
    Di, Shuai
    Lv, Wenjing
    Jia, Yaqing
    Fu, Shijie
    Fang, Lide
    APPLIED PHYSICS B-LASERS AND OPTICS, 2021, 127 (01):
  • [33] A comparison of atmospheric CO2 concentration GOSAT-based observations and model simulations
    LEI LiPing
    GUAN XianHua
    ZENG ZhaoCheng
    ZHANG Bing
    RU Fei
    BU Ran
    ScienceChina(EarthSciences), 2014, 57 (06) : 1393 - 1402
  • [34] A comparison of atmospheric CO2 concentration GOSAT-based observations and model simulations
    LiPing Lei
    XianHua Guan
    ZhaoCheng Zeng
    Bing Zhang
    Fei Ru
    Ran Bu
    Science China Earth Sciences, 2014, 57 : 1393 - 1402
  • [35] Study on the Prediction Model and Cycle Control Strategy of CO2 Concentration for Sporocarp of Pleurotus Eryngii
    Tian, Xiaoqing
    Zhao, Li
    Lai, Huige
    Zhu, Xuejun
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 425 - 430
  • [36] MEASUREMENT AND CONTROL OF CO2 CONCENTRATION IN AIR IS INFLUENCED BY DESICCANT
    SAMISH, YB
    PHOTOSYNTHETICA, 1978, 12 (01) : 73 - 75
  • [37] Robust simultaneous control of temperature and CO2 concentration in greenhouses
    Linker, R
    Gutman, PO
    Seginer, I
    MATHEMATICAL AND CONTROL APPLICATIONS IN AGRICULTURE AND HORTICULTURE, 1997, : 31 - 36
  • [38] CONTROL OF THE CO2 PROCESS BY A POTENTIOMETRIC TECHNIQUE.
    Fiala, A.
    Zemeik, L.
    Rusin, K.
    1600, (144):
  • [39] Effect of CO2 concentration on the electrolytic conversion of CO2 to CO
    Liu, Zengcai
    Yang, Hongzhou
    Sajjad, Syed
    Kaczur, Jerry
    Masel, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [40] Is CO2 Indoor Pollutant? Responds
    Fisk, William J.
    ASHRAE JOURNAL, 2013, 55 (05) : 14 - 14