Control of indoor CO2 concentration based on a process model

被引:12
|
作者
Skrjanc, Igor [2 ]
Subic, Barbara [1 ]
机构
[1] Univ Ljubljana, Fac Civil Engn, Jamova 1000 2, Slovenia
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana 1000, Slovenia
关键词
Modeling; Internal model control; PREDICTIVE FUNCTIONAL CONTROL; ENERGY-CONSUMPTION; AIR; STRATEGIES; SYSTEM;
D O I
10.1016/j.autcon.2014.02.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-tight buildings need to have ventilation systems, although the use of these systems results in heavy energy consumption within the building sector. For this reason they have to be adequately regulated in order to achieve good indoor air quality and lower operation costs. The main challenge is to optimize regulation in office buildings, theaters, museums, and schools, where there are large fluctuations and heavy operating costs. Each further optimization leads directly to a better indoor climate and a reduction in energy consumption. In the case of ventilation systems. PI or PID regulators are usually used. In the described research an internal model control (IMC) system was designed with an internal loop, which constantly checks the momentary CO2 concentration, and makes the necessary adjustments to the air flow. The results showed a significant improvement in the CO2 level when using an IMC controller, in comparison with PI controller. The desired indoor air quality is achieved more than 80% of the time, with lower operating costs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 126
页数:5
相关论文
共 50 条
  • [21] MEASUREMENT AND SIMULATION OF INDOOR AIR QUALITY AND CO2 CONCENTRATION IN A HOTEL ROOM
    Asadi, Ehsan
    da Silva, Manuel Gameiro
    Costa, Jose J.
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 4, 2010, : 545 - 554
  • [22] Effects of indoor plants on CO2 concentration, indoor air temperature and relative humidity in office buildings
    Jiang, Junzhiwei
    Irga, Peter
    Coe, Robert
    Gibbons, Philip
    PLOS ONE, 2024, 19 (07):
  • [23] Amine-Based Latex Coatings for Indoor Air CO2 Control in Commercial Buildings
    Krishnamurthy, Anirudh
    Salunkhe, Buddhabhushan
    Zore, Ashish
    Rownaghi, Ali
    Schuman, Thomas
    Rezaei, Fateme
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (18) : 16594 - 16604
  • [24] CO2 CONTROL SYSTEM DESIGN BASED ON OPTIMIZED REGULATION MODEL
    Xin, P. P.
    Zhang, H. H.
    Hu, J.
    Shao, Z. C.
    Peters, R. T.
    APPLIED ENGINEERING IN AGRICULTURE, 2019, 35 (03) : 377 - 388
  • [25] A model-based control of CO2 concentration in multi-zone ACB air-conditioning systems
    Wang, Haijing
    Xie, Lihua
    Liu, Shuai
    Xu, Juanjuan
    2016 12TH IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA), 2016, : 467 - 472
  • [26] Optimization of Sensor Node Placement for CO2 Concentration Monitoring Based on Wireless Sensor Networks in an Indoor Environment
    Yokoyama, Tomoya
    Narieda, Shusuke
    Naruse, Hiroshi
    IEEE SENSORS LETTERS, 2024, 8 (04) : 1 - 4
  • [27] A cascade prediction model of CO/CO2 in the sintering process
    Xu B.
    Chen X.
    Wu M.
    Cao W.
    Chen, Xin (chenxin@cug.edu.cn), 2017, Fuji Technology Press (21) : 785 - 794
  • [28] Integrated task performance score for the building occupants based on the CO2 concentration and indoor climate factors changes
    Hong, Taehoon
    Kim, Jimin
    Lee, Myeonghwi
    APPLIED ENERGY, 2018, 228 : 1707 - 1713
  • [29] Indoor Air Quality Control for Energy-Efficient Buildings Using CO2 Predictive Model
    Wang, Zhu
    Wang, Lingfeng
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2012, : 133 - 138
  • [30] Research on the measurement of CO2 concentration based on multi-band fusion model
    Honglian Li
    Shuai Di
    Wenjing Lv
    Yaqing Jia
    Shijie Fu
    Lide Fang
    Applied Physics B, 2021, 127