Evaluation of a novel personal nanoparticle sampler

被引:7
|
作者
Zhou, Yue [1 ]
Irshad, Hammad [1 ]
Tsai, Chuen-Jinn [2 ]
Hung, Shao-Ming [2 ]
Cheng, Yung-Sung [1 ]
机构
[1] Lovelace Resp Res Inst, Albuquerque, NM 87108 USA
[2] NCTU, Hsinchu, Taiwan
关键词
INHALABLE AEROSOL SAMPLERS; ULTRAFINE PARTICLES; DEPOSITION; EXPOSURE; PERFORMANCE; AIRWAYS; CALIBRATION; WORKPLACES; EFFICIENCY; CHILDREN;
D O I
10.1039/c3em00497j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work investigated the performance in terms of collection efficiency and aspiration efficiency of a personal sampler capable of collecting ultrafine particles (nanoparticles) in the occupational environment. This sampler consists of a cyclone for respirable particle classification, micro-orifice impactor stages with an acceleration nozzle to achieve nanoparticle classification and a backup filter to collect nanoparticles. Collection efficiencies of the cyclone and impactor stages were determined using monodisperse polystyrene latex and silver particles, respectively. Calibration of the cyclone and impactor stages showed 50% cut-off diameters of 3.95 mu m and 94.7 nm meeting the design requirements. Aspiration efficiencies of the sampler were tested in a wind tunnel with wind speeds of 0.5, 1.0, and 1.5 m s(-1). The test samplers were mounted on a full size mannequin with three orientations toward the wind direction (0 degrees, 90 degrees, and 180 degrees). Monodisperse oleic acid aerosols tagged with sodium fluorescein in the size range of 2 to 10 mu m were used in the test. For particles smaller than 2 mu m, the fluorescent polystyrene latex particles were generated by using nebulizers. For comparison of the aspiration efficiency, a NIOSH two-stage personal bioaerosol sampler was also tested. Results showed that the orientation-averaged aspiration efficiency for both samplers was close to the inhalable fraction curve. However, the direction of wind strongly affected the aspiration efficiency. The results also showed that the aspiration efficiency was not affected by the ratio of free-stream velocity to the velocity through the sampler orifice. Our evaluation showed that the current design of the personal sampler met the designed criteria for collecting nanoparticles <= 100 nm in occupational environments.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [1] Design and experimental evaluation of a new nanoparticle thermophoretic personal sampler
    Azong-Wara, Nkwenti
    Asbach, Christof
    Stahlmecke, Burkhard
    Fissan, Heinz
    Kaminski, Heinz
    Plitzko, Sabine
    Bathen, Dieter
    Kuhlbusch, Thomas A. J.
    JOURNAL OF NANOPARTICLE RESEARCH, 2013, 15 (04)
  • [2] Design and experimental evaluation of a new nanoparticle thermophoretic personal sampler
    Nkwenti Azong-Wara
    Christof Asbach
    Burkhard Stahlmecke
    Heinz Fissan
    Heinz Kaminski
    Sabine Plitzko
    Dieter Bathen
    Thomas A. J. Kuhlbusch
    Journal of Nanoparticle Research, 2013, 15
  • [3] Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces
    Tsai, Chuen-Jinn
    Liu, Chun-Nan
    Hung, Shao-Ming
    Chen, Sheng-Chieh
    Uang, Shi-Nian
    Cheng, Yung-Sung
    Zhou, Yue
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (08) : 4546 - 4552
  • [4] A Personal Nanoparticle Respiratory Deposition (NRD) Sampler
    Cena, Lorenzo G.
    Anthony, T. Renee
    Peters, Thomas M.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (15) : 6483 - 6490
  • [5] Assessment of personal exposure to airborne nanomaterials: Evaluation of a novel sampler
    Faure, Bertrand
    Dozol, Helene
    Brouard, Christophe
    Guiot, Arnaud
    Clavaguera, Simon
    5TH NANOSAFE INTERNATIONAL CONFERENCE ON HEALTH AND SAFETY ISSUES RELATED TO NANOMATERIALS FOR A SOCIALLY RESPONSIBLE APPROACH (NANOSAFE 2016), 2017, 838
  • [6] Optimisation of a thermophoretic personal sampler for nanoparticle exposure studies
    Nkwenti Azong-Wara
    Christof Asbach
    Burkhard Stahlmecke
    Heinz Fissan
    Heinz Kaminski
    Sabine Plitzko
    Thomas A. J. Kuhlbusch
    Journal of Nanoparticle Research, 2009, 11 : 1611 - 1624
  • [7] Development of a Transfer Function for a Personal, Thermophoretic Nanoparticle Sampler
    Leith, David
    Miller-Lionberg, Dan
    Casuccio, Gary
    Lersch, Traci
    Lentz, Hank
    Marchese, Anthony
    Volckens, John
    AEROSOL SCIENCE AND TECHNOLOGY, 2014, 48 (01) : 81 - 89
  • [8] Optimisation of a thermophoretic personal sampler for nanoparticle exposure studies
    Azong-Wara, Nkwenti
    Asbach, Christof
    Stahlmecke, Burkhard
    Fissan, Heinz
    Kaminski, Heinz
    Plitzko, Sabine
    Kuhlbusch, Thomas A. J.
    JOURNAL OF NANOPARTICLE RESEARCH, 2009, 11 (07) : 1611 - 1624
  • [9] EVALUATION OF A COAL MINE PERSONAL DUST SAMPLER
    CAPLAN, K
    SORENSON, S
    DOEMENY, L
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1972, 33 (02): : 69 - &
  • [10] Chamber evaluation of a personal, bioaerosol cyclone sampler
    Macher, Janet
    Chen, Bean
    Rao, Carol
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (11) : 702 - 712