Energy audit case studies II - air conditioning (cooling) systems

被引:0
|
作者
Bhatt, MS
机构
关键词
central air conditioning plant; energy audit; circuit efficiency; energy conservation;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper discusses a novel methodology for determination of the efficiencies of each segment in a centralized air conditioning (A/C) plant. The methodology is useful analytical tool in energy audit where it can be used for decision support for evolution of energy conservation measures and techno-economic evaluation of the various options. The procedure is applied to three A/C plants of capacity range from 50 to 500 TR. Losses in chilled air ducts and cycling losses in the refrigerant circuit are identified to be the major causes for decrease in the efficiency and capacity under rating of the systems. Effective controls and insulation of air ducts: have been shown to be: the must cost effective solutions to improve the energy efficiency of the A/C plants. The generalized experimental data on overall performance of sixteen A/C plants is also provided. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 50 条
  • [1] Energy Audit Analysis of Residential Air-Conditioning Systems in Austin, Texas
    Rhodes, Joshua
    Stephens, Brent
    Webber, Michael E.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 143 - 150
  • [2] Energy audit case studies I - steam systems
    Bhatt, MS
    APPLIED THERMAL ENGINEERING, 2000, 20 (03) : 285 - 296
  • [3] COOLING TOWERS FOR AIR CONDITIONING SYSTEMS.
    Hill, G.B.
    1976, 50 (58): : 14 - 17
  • [4] The Comparison of Operating Energy Consumptions of Six Air Conditioning Systems for Seasonal Cooling Demand
    Wang, Zhiwei
    Zhang, Fan
    Zhao, Yue
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 379 - 383
  • [5] Energy performance of air-conditioning systems using an indirect evaporative, cooling combined with a cooling/reheating treatment
    Cianfrini, Claudio
    Corcione, Massimo
    Habib, Emanuele
    Quintino, Alessandro
    ENERGY AND BUILDINGS, 2014, 69 : 490 - 497
  • [6] Case analysis on energy saving improvement of commercial air conditioning systems
    Lee, Kuang-Yi
    Chu, Yuan-Min
    Chen, Chun-Chung
    Tsai, Cheng-Lung
    Lou, Shi-Jer
    PROCEEDINGS OF THE 2019 IEEE EURASIA CONFERENCE ON IOT, COMMUNICATION AND ENGINEERING (ECICE), 2019, : 306 - 309
  • [7] Modeling of air conditioning systems for cooling of data centers
    Anton, R
    Jonsson, H
    Palm, B
    ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 552 - 558
  • [8] Researches on the evaporative cooling air conditioning standard of utilizing renewable energy dry air cooling
    Wang, Chao
    Huang, Xiang
    Wu, Zhi-Xiang
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [9] Experimental studies on natural bank type heating/cooling energy saving Air conditioning system
    Goyal, Vaishali
    Asati, Arun Kumar
    Garg, Rajeev Kumar
    Arora, Amit
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024, 238 (01) : 91 - 100
  • [10] Energy Studies on Central and Variable Refrigerant Flow Air-Conditioning Systems
    Abdullah, H.
    Nitamakwuavan, S.
    Jalaludin, A. F.
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 486 - 490