Energy audit case studies II - air conditioning (cooling) systems

被引:0
|
作者
Bhatt, MS
机构
关键词
central air conditioning plant; energy audit; circuit efficiency; energy conservation;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper discusses a novel methodology for determination of the efficiencies of each segment in a centralized air conditioning (A/C) plant. The methodology is useful analytical tool in energy audit where it can be used for decision support for evolution of energy conservation measures and techno-economic evaluation of the various options. The procedure is applied to three A/C plants of capacity range from 50 to 500 TR. Losses in chilled air ducts and cycling losses in the refrigerant circuit are identified to be the major causes for decrease in the efficiency and capacity under rating of the systems. Effective controls and insulation of air ducts: have been shown to be: the must cost effective solutions to improve the energy efficiency of the A/C plants. The generalized experimental data on overall performance of sixteen A/C plants is also provided. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 50 条
  • [41] Air conditioning systems for school buildings: a case study
    Ascione, Fabrizio
    Bellia, Laura
    Mele, Carlo
    Minichiello, Francesco
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENERGY, 2016, 169 (02) : 52 - 78
  • [42] SOLAR COOLING AND AIR-CONDITIONING
    GROSSMAN, G
    JOHANNSEN, A
    PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 1981, 7 (03) : 185 - 228
  • [43] Experimental investigation of PCM transient performance in free cooling of the fresh air of air conditioning systems
    Nada, S. A.
    Alshaer, W. G.
    Saleh, R. M.
    JOURNAL OF BUILDING ENGINEERING, 2020, 29
  • [44] Estimation and measurement of electric energy consumption due to air conditioning cooling load
    Al-Rabghi, OM
    Al-Beirutty, MH
    Fathalah, KA
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (14) : 1527 - 1542
  • [45] Energy audit and analysis of chilled water system for air conditioning of commercial buildings in Shanghai
    Wang, CQ
    Long, WD
    Ding, WT
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 123 - 127
  • [46] On energy effectiveness of an air turbine in the blade cooling systems
    E. N. Bogomolov
    M. N. Oreshkina
    Russian Aeronautics (Iz VUZ), 2012, 55 (1) : 28 - 35
  • [47] The influence of street canyons on the cooling loads of buildings and the performance of air conditioning systems
    Papadopoulos, AM
    ENERGY AND BUILDINGS, 2001, 33 (06) : 601 - 607
  • [48] Experimental and numerical investigations of the energy efficiency of conventional air conditioning systems in cooling mode and comfort assurance in office buildings
    Sarbu, Ioan
    Adam, Marius
    ENERGY AND BUILDINGS, 2014, 85 : 45 - 58
  • [49] ENHANCEMENT OPTIONS FOR SEPARATE SENSIBLE AND LATENT COOLING AIR-CONDITIONING SYSTEMS
    Ling, J.
    Kuwabara, O.
    Hwang, Y.
    Radermacher, R.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 3096 - +
  • [50] Enhancement options for separate sensible and latent cooling air-conditioning systems
    Ling, Jiazhen
    Kuwabara, Osamu
    Hwang, Yunho
    Rademacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2013, 36 (01) : 45 - 57