Modification of carbon paste with congo red supported on multi-walled carbon nanotube for voltammetric determination of uric acid in the presence of ascorbic acid

被引:25
|
作者
Shahrokhian, Saeed [1 ,2 ]
Zare-Mehrjardi, Hamid Reza [1 ]
Khajehsharifi, Habibollah [3 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[2] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
[3] Univ Yasuj, Fac Sci, Dept Chem, Yasuj 75914353, Iran
关键词
Carbon-paste electrode; Chemically modified electrode; Congo red; Multi-walled carbon nanotube; Uric acid; Ascorbic acid; ELECTROCHEMICAL SENSORS; MODIFIED ELECTRODE; CYTOCHROME-C; FUNCTIONALIZATION; BIOSENSORS; DOPAMINE; FILM; PURIFICATION; PEROXIDASE; ADSORPTION;
D O I
10.1007/s10008-008-0733-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A chemically modified carbon-paste electrode (CPE) is prepared by incorporating congo red (CR) immobilized on multi-walled carbon nanotube (MWCNT). The results show that CR is effectively immobilized on the surface of MWCNT under the ultrasonic agitation in aqueous solution and further incorporating the nafion. The prepared electrode, due to the electrostatic repulsions between the CR and ascorbate anion, is capable to mask the response of the ascorbic acid (AA) completely and provide an effective method for the detection of minor amounts of uric acid (UA) in the presence of high concentrations of AA. On the other hand, an increase in the microscopic area of the electrode by addition of MWCNT together with the electrocatalytic activity caused to a significant enhancement in the voltammetric response to UA. Optimization of the amounts of composite modifier in the matrix of CPE is performed by cyclic and differential pulse voltammetric measurements. The modified electrode shows a linear response to UA in the range of 1.0 x 10(-7)-1.0 x 10(-4) M with a detection limit of 1.0 x 10(-8) M. The electrode exhibits excellent accuracies for the determination of UA in the presence of high concentrations of AA (a recovery of 97.6%). The response of the electrode toward sulfhydryl compounds such as cysteine, penicillamine, and glutathione is not considerable. This reveals a good selectivity for the voltammetric response toward UA. The effective electrocatalytic property, ability for masking the voltammetric responses of the other biologically reducing agents, ease of preparation, and surface regeneration by simple polishing together with high reproducibility and stability of the responses make the modified electrode suitable for the selective and sensitive voltammetric detection of sub-micromolar amounts of UA in clinical and pharmaceutical preparations.
引用
收藏
页码:1567 / 1575
页数:9
相关论文
共 50 条
  • [41] Simultaneous determination of dopamine, ascorbic acid and uric acid using a multi-walled carbon nanotube and reduced graphene oxide hybrid functionalized by PAMAM and Au nanoparticles
    Wang, Siyuan
    Zhang, Wen
    Zhong, Xia
    Chai, Yaqin
    Yuan, Ruo
    ANALYTICAL METHODS, 2015, 7 (04) : 1471 - 1477
  • [42] Simultaneous voltammetric determination of uric acid and ascorbic acid using carbon paste/cobalt Schiff base composite electrode
    Mandana Amiri
    Abolfazl Bezaatpour
    Zohreh Pakdel
    Khadijeh Nekoueian
    Journal of Solid State Electrochemistry, 2012, 16 : 2187 - 2195
  • [43] Simultaneous voltammetric determination of uric acid and ascorbic acid using carbon paste/cobalt Schiff base composite electrode
    Amiri, Mandana
    Bezaatpour, Abolfazl
    Pakdel, Zohreh
    Nekoueian, Khadijeh
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (06) : 2187 - 2195
  • [44] Electrochemical Determination of Ascorbic Acid Using Poly(Xanthurenic Acid) and Multi-Walled Carbon Nanotubes
    Lin, Kuo-Chiang
    Yeh, Pin-Chun
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (12): : 12752 - 12763
  • [45] VOLTAMMETRIC DETERMINATION OF ASCORBIC-ACID BY USE OF A CARBON PASTE ELECTRODE
    LINDQUIST, J
    ANALYST, 1975, 100 (1190) : 339 - 348
  • [46] Simultaneous voltammetric determination of uric acid and ascorbic acid using a carbon-paste electrode modified with malt-walled carbon Nanotubes/Nafion and Cobalt(II)-nitrosalophen
    Shahrokhian, Saeed
    Zare-Mehrjardi, Hamid Reza
    ELECTROANALYSIS, 2007, 19 (21) : 2234 - 2242
  • [47] Selective electrochemical determination of uric acid in the presence of ascorbic acid using a carbon paste electrode modified with β-cyclodextrin
    Ramirez-Berriozabal, Minerva
    Galicia, Laura
    Gutierrez-Granados, Silvia
    Cortes, Jose Sandoval
    Herrasti, Pilar
    ELECTROANALYSIS, 2008, 20 (15) : 1678 - 1683
  • [48] Selective and Simultaneous Voltammetric Determination of Glutathione, Uric Acid and Penicillamine by a Modified Carbon Nanotube Paste Electrode
    Mazloum-Ardakani, Mohammad
    Sheikh-Mohseni, Mohammad Ali
    Mirjalili, Bibi-Fatemeh
    ELECTROANALYSIS, 2013, 25 (08) : 2021 - 2029
  • [49] Simultaneous Voltammetric Determination of Norepinephrine, Uric Acid and Folic Acid at the Surface of Modified Chloranil Carbon Nanotube Paste Electrode
    Yaghoubian, Halimeh
    Soltani-Nejad, Vahhab
    Roodsaz, Sara
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (10): : 1411 - 1421
  • [50] Fabrication of a fast, simple and sensitive voltammetric sensor for the simultaneous determination of 4-aminohippuric acid and uric acid using a functionalized multi-walled carbon nanotube modified glassy carbon electrode
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    Ahmadi, Farzaneh
    ANALYTICAL METHODS, 2012, 4 (06) : 1825 - 1832