Modification of carbon paste with congo red supported on multi-walled carbon nanotube for voltammetric determination of uric acid in the presence of ascorbic acid

被引:25
|
作者
Shahrokhian, Saeed [1 ,2 ]
Zare-Mehrjardi, Hamid Reza [1 ]
Khajehsharifi, Habibollah [3 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[2] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
[3] Univ Yasuj, Fac Sci, Dept Chem, Yasuj 75914353, Iran
关键词
Carbon-paste electrode; Chemically modified electrode; Congo red; Multi-walled carbon nanotube; Uric acid; Ascorbic acid; ELECTROCHEMICAL SENSORS; MODIFIED ELECTRODE; CYTOCHROME-C; FUNCTIONALIZATION; BIOSENSORS; DOPAMINE; FILM; PURIFICATION; PEROXIDASE; ADSORPTION;
D O I
10.1007/s10008-008-0733-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A chemically modified carbon-paste electrode (CPE) is prepared by incorporating congo red (CR) immobilized on multi-walled carbon nanotube (MWCNT). The results show that CR is effectively immobilized on the surface of MWCNT under the ultrasonic agitation in aqueous solution and further incorporating the nafion. The prepared electrode, due to the electrostatic repulsions between the CR and ascorbate anion, is capable to mask the response of the ascorbic acid (AA) completely and provide an effective method for the detection of minor amounts of uric acid (UA) in the presence of high concentrations of AA. On the other hand, an increase in the microscopic area of the electrode by addition of MWCNT together with the electrocatalytic activity caused to a significant enhancement in the voltammetric response to UA. Optimization of the amounts of composite modifier in the matrix of CPE is performed by cyclic and differential pulse voltammetric measurements. The modified electrode shows a linear response to UA in the range of 1.0 x 10(-7)-1.0 x 10(-4) M with a detection limit of 1.0 x 10(-8) M. The electrode exhibits excellent accuracies for the determination of UA in the presence of high concentrations of AA (a recovery of 97.6%). The response of the electrode toward sulfhydryl compounds such as cysteine, penicillamine, and glutathione is not considerable. This reveals a good selectivity for the voltammetric response toward UA. The effective electrocatalytic property, ability for masking the voltammetric responses of the other biologically reducing agents, ease of preparation, and surface regeneration by simple polishing together with high reproducibility and stability of the responses make the modified electrode suitable for the selective and sensitive voltammetric detection of sub-micromolar amounts of UA in clinical and pharmaceutical preparations.
引用
收藏
页码:1567 / 1575
页数:9
相关论文
共 50 条