A novel geothermal combined cooling and power cycle based on the absorption power cycle: Energy, exergy and exergoeconomic analysis

被引:131
|
作者
Parikhani, Towhid [1 ]
Ghaebi, Hadi [1 ]
Rostamzadeh, Hadi [1 ]
机构
[1] Univ Mohaghegh Ardabili, Fac Engn, Dept Mech Engn, POB 179, Ardebil, Iran
关键词
Combined cooling and power (CCP) system; Absorption power cycle (APC); Energy and exergy analysis; Exergoeconomic analysis; Geothermal; ORGANIC RANKINE-CYCLE; WATER COMBINED POWER; THERMOECONOMIC ANALYSIS; KALINA CYCLE; THERMODYNAMIC ANALYSIS; REFRIGERATION CYCLE; SYSTEM DRIVEN; HEAT; COGENERATION; OPTIMIZATION;
D O I
10.1016/j.energy.2018.01.153
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy, exergy, and exergoeconomic analysis of a novel combined cooling and power (CCP) system for producing cooling and power outputs are presented based on the absorption power cycle (APC), using geothermal energy as low-temperature heat source. A comprehensive thermodynamic modeling of the proposed CCP system is carried out leading to determine the main source of irreversibility and performance characteristics of the system for a better thermal design purpose. In the parametric study, the effect of key thermodynamic parameters (i.e., generator hot pinch point temperature difference (PPTD), generator cold PPTD, ammonia concentration, absorber minimum temperature difference, condenser minimum temperature difference, evaporator temperature, and geothermal temperature) on the key performance parameters (i.e., net output power, cooling capacity, thermal efficiency, exergy efficiency, and sum unit cost of product (SUCP) of system) are investigated. It is found that the proposed system can produce cooling capacity and net output power of 221.4 kW and 161.2 kW, respectively, under supplying 2333 kW heat from the geothermal source. In this case, the overall thermal efficiency, exergy efficiency, and SUCP of system are calculated by 16.4%, 28.95% and 93.87 $/GJ, respectively. From exergy analysis it is understood that among all components, absorber accounted for the largest contribution of exergy destruction which constituted around 39.89% of the overall exergy destruction of system. In addition, the highest cost of exergy destruction corresponded to the absorber which is followed by the condenser. Finally, parametric study revealed that the exergy efficiency of the proposed system can be maximized based upon the ammonia concentration and evaporator temperature. Moreover, it is shown that the thermal efficiency of system can be increased by increasing of the generator hot PPTD and evaporator temperature or decreasing ammonia concentration, absorber and condenser minimum temperature differences, and geothermal temperature. While, it is also found that the SUCP of system can be decreased by increasing the generator cold PPTD, condenser minimum temperature difference, and geothermal temperature or decreasing the generator hot PPTD, absorber minimum temperature difference, and evaporator temperature. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 50 条
  • [41] A combined power/cooling cycle
    Xu, F
    Goswami, DY
    Bhagwat, SS
    [J]. ENERGY, 2000, 25 (03) : 233 - 246
  • [42] Energy and exergy analyses for a combined cycle power plant in Jordan
    Altarawneh, Obieda R.
    Alsarayreh, Alanood A.
    Al-Falahat, Ala'a M.
    Al-Kheetan, Mazen J.
    Alrwashdeh, Saad S.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 31
  • [43] Combined Cycle Power Plant Performance Evaluation Using Exergy and Energy Analysis
    Pattanayak, Lalatendu
    Sahu, Jaya Narayan
    Mohanty, Pravakar
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2017, 36 (04) : 1180 - 1186
  • [44] Energy and exergy analysis of intercooled combustion-turbine based combined cycle power plant
    Sanjay
    Prasad, Bishwa N.
    [J]. ENERGY, 2013, 59 : 277 - 284
  • [45] Exergoeconomic analysis with reliability and availability considerations of a nuclear energy-based combined cycle power plant
    Zare, V.
    [J]. ENERGY, 2016, 96 : 187 - 196
  • [46] Energy and Exergy Analysis of Gas Turbine - Fuel Cell based combined Cycle Power Plant
    Sreeramulu, M.
    Gupta, A. V. S. S. K. S.
    Srinivas, T.
    [J]. PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY 2011, 2012, : 85 - 94
  • [47] Exergy, exergoeconomic, and exergoenvironmental optimization of the geothermal binary cycle power plant at Ampallas, West Sulawesi, Indonesia
    Nasruddin, N.
    Saputra, Irfan Dwi
    Mentari, Tania
    Bardow, Andre
    Marcelina, Olga
    Berlin, Susanto
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19
  • [48] Conventional and advanced exergy investigation of a double flash cycle integrated by absorption cooling, ORC, and TEG power system driven by geothermal energy
    Mohammadi, Zahra
    Fallah, Mohsen
    [J]. ENERGY, 2023, 282
  • [49] Exergy analysis, parametric analysis and optimization for a novel combined power and ejector refrigeration cycle
    Dai, Yiping
    Wang, Jiangfeng
    Gao, Lin
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (10) : 1983 - 1990
  • [50] Thermodynamic and thermoeconomic analysis of a novel combined cooling and power (CCP) cycle
    Rostamzadeh, Hadi
    Ghaebi, Hadi
    Parikhani, Towhid
    [J]. APPLIED THERMAL ENGINEERING, 2018, 139 : 474 - 487