Vented versus unvented chest seals for treatment of pneumothorax and prevention of tension pneumothorax in a swine model

被引:24
|
作者
Kheirabadi, Bijan S. [1 ]
Terrazas, Irasema B. [1 ]
Koller, Alexandra [1 ]
Allen, Paul B. [1 ]
Klemcke, Harold G. [1 ]
Convertino, Victor A. [1 ]
Dubick, Michael A. [1 ]
Gerhardt, Robert T. [1 ]
Blackbourne, Lorne H. [1 ]
机构
[1] US Army Inst Surg Res, San Antonio, TX USA
来源
关键词
Pneumothorax; chest seals; tension pneumothorax; combat casualty care; swine; COMBAT CASUALTIES;
D O I
10.1097/TA.0b013e3182988afe
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Unvented chest seals (CSs) are currently recommended for the management of penetrating thoracic injuries in the battlefield. Since no supporting data exist, we compared the efficacy of a preferred unvented with that of a vented CS in a novel swine model of pneumothorax (PTx). METHODS: An open chest wound was created in the left thorax of spontaneously air-breathing anesthetized pigs (n = 8). A CS was applied over the injury, then tension PTx was induced by incremental air injections (0.2 L) into the pleural cavity via a cannula that was also used to measure intrapleural pressure (IP). Both CS were tested on each pig in series. Tidal volume (V-T), respiratory rate, IP, heart rate, mean arterial pressure, cardiac output, central venous pressure, pulmonary arterial pressure, venous and peripheral oxygen saturations (SvO(2), SpO(2)) were recorded. Tension PTx was defined as a mean IP equal to or greater than + 1 mm Hg plus significant (20-30%) deviation in baseline levels of the previously mentioned parameters and confirmed by chest x-ray study. PaO2 and PaCo2 were also measured. RESULTS: PTx produced immediate breathing difficulty and significant rises in IP and pulmonary arterial pressure and falls in V-T, SpO(2), and SvO(2). Both CSs returned these parameters to near baseline within 5 minutes of application. After vented CS was applied, serial air injections up to 2 L resulted in no significant change in the previously mentioned parameters. After unvented CS application, progressive deterioration of all respiratory parameters and onset of tension PTx were observed in all subjects after approximately 1.4-L air injection. CONCLUSION: Both vented and unvented CSs provided immediate improvements in breathing and blood oxygenation in our model of penetrating thoracic trauma. However, in the presence of ongoing intrapleural air accumulation, the unvented CS led to tension PTx, hypoxemia, and possible respiratory arrest, while the vented CS prevented these outcomes. (J Trauma Acute Care Surg. 2013; 75: 150-156. Copyright (C) 2013 by Lippincott Williams & Wilkins)
引用
下载
收藏
页码:150 / 156
页数:7
相关论文
共 50 条
  • [21] Devices Used in the Treatment of Tension Pneumothorax
    Andrew J. Kirmse
    James H. Paxton
    Current Emergency and Hospital Medicine Reports, 2023, 11 : 151 - 157
  • [22] TREATMENT OF TENSION CAVITIES WITH PNEUMOTHORAX - DISCUSSION
    BROCK, BL
    DISEASES OF THE CHEST, 1947, 13 (02): : 150 - 152
  • [23] Do vented chest seals differ in efficacy? An experimental evaluation using a swine hemopneumothorax model
    Kheirabadi, Bijan Shams
    Terrazas, Irasema B.
    Miranda, Nahir
    Voelker, Amber N.
    Arnaud, Francoise
    Klemcke, Harold G.
    Butler, Frank K.
    Dubick, Michael A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2017, 83 (01): : 182 - 189
  • [24] Improvised chest tube drain for decompression of an acute tension pneumothorax
    Vinson, ED
    MILITARY MEDICINE, 2004, 169 (05) : 403 - 405
  • [25] TENSION PNEUMOTHORAX DUE TO INTRAPULMONARY PLACEMENT OF INTERCOSTAL CHEST DRAIN
    MCCONAGHY, PM
    KENNEDY, N
    ANAESTHESIA AND INTENSIVE CARE, 1995, 23 (04) : 496 - 498
  • [26] OPEN OR CLOSED CHEST MESSAGE - TENSION PNEUMOTHORAX AND CARDIAC ARREST
    SIVAK, BJ
    BULLETIN SINAI HOSPITAL OF DETROIT, 1974, 22 (02): : 92 - 92
  • [27] Pigtail catheters versus traditional chest drains for pneumothorax treatment in two NICUs
    Panza, Raffaella
    Prontera, Giorgia
    Ives, Kevin Nicholas
    Zivanovic, Sanja
    Roehr, Charles C.
    Quercia, Michele
    Schettini, Federico
    Bianchi, Francesco Paolo
    Tafuri, Silvio
    Di Mauro, Antonio
    Laforgia, Nicola
    EUROPEAN JOURNAL OF PEDIATRICS, 2020, 179 (01) : 73 - 79
  • [28] Pigtail catheters versus traditional chest drains for pneumothorax treatment in two NICUs
    Raffaella Panza
    Giorgia Prontera
    Kevin Nicholas Ives
    Sanja Zivanovic
    Charles C. Roehr
    Michele Quercia
    Federico Schettini
    Francesco Paolo Bianchi
    Silvio Tafuri
    Antonio Di Mauro
    Nicola Laforgia
    European Journal of Pediatrics, 2020, 179 : 73 - 79
  • [29] Demand valve ventilation in a swine pneumothorax model
    Murray, JM
    Seaberg, DC
    Menegazzi, JJ
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (01): : 13 - 15
  • [30] PLEUROCATH FOR THE TREATMENT OF TENSION PNEUMOTHORAX IN EMERGENCY SERVICE
    KLOSS, T
    DEIN, R
    LEMKE, J
    KLAUCKE, D
    ANAESTHESIST, 1982, 31 (09): : 538 - 539