Volumetric Blood Flow Measurement in the Ophthalmic Artery Using Colour Doppler

被引:6
|
作者
Katamay, R. [1 ]
Fleischlin, C. [1 ]
Gugleta, K. [1 ]
Flammer, J. [1 ]
Orguel, S. [1 ]
机构
[1] Univ Eye Clin, Basel, Switzerland
关键词
ophthalmic artery; volumetric blood flow; ultrasound; colour Doppler imaging; cardiac cycle; velocity; vessel diameter; cross-sectional area; PRESSURE MEASUREMENT; FINAPRES;
D O I
10.1055/s-0028-1109304
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Herewith we present a new method for measurement of the volumetric blood flow in absolute units in the ophthalmic artery. Patients and Methods: A Philips EnVisor HD ultrasound unit with a 12 - 3 MHz linear transducer was used to measure flow in the ophthalmic artery in 8 healthy young subjects. The transducer was mounted on a custom-made holder which enabled precise and reproducible positioning in 3 axes as well as in rotation angle. Blood flow velocity and vessel diameter were measured during 10 consecutive heartbeats. The measurements were ECG-gated. Blood vessel diameter and blood flow velocity were calculated in an average heartbeat cycle. Hence blood volume over time within a heartbeat cycle as well as blood flow in mL/min were determined. Simultaneously, cardiovascular parameters have been recorded by Finapres. Short time reproducibility (5 measurements on day 1) and long time reproducibility (5 days once daily) as well as interindividual coefficient of variation were evaluated. Results: Average blood flow in the ophthalmic artery in all measurements was 39.7 mL/min. The short-term intraindividual coefficient of variation was 24.1 +/- 9.2%, the long-term coefficient 32.0 +/- 13.8%. Interindividual coefficient of variation was 32.8%. Conclusions: Our method allows volumetric blood flow measurements in the ophthalmic artery in absolute units, reproducible to a limited extent.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [31] TOTAL BLOOD-FLOW IN THE OPHTHALMIC ARTERY
    GRUENDLER, A
    MICHELSON, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 865 - 865
  • [32] Measurement of volumetric flow with no angle correction using multiplanar pulsed Doppler ultrasound
    Poulsen, JK
    Kim, WY
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 589 - 599
  • [33] Developmental changes in spiral artery blood flow in the human placenta observed with colour Doppler ultrasonography
    Collins, S. L.
    Stevenson, G. N.
    Noble, J. A.
    Impey, L.
    PLACENTA, 2012, 33 (10) : 782 - 787
  • [34] Reproducibility of blood flow velocity measurements using colour decoded Doppler imaging
    Matthiessen, ET
    Zeitz, O
    Richard, G
    Klemm, M
    EYE, 2004, 18 (04) : 400 - 405
  • [35] Reproducibility of blood flow velocity measurements using colour decoded Doppler imaging
    E T Matthiessen
    O Zeitz
    G Richard
    M Klemm
    Eye, 2004, 18 : 400 - 405
  • [36] DOPPLER OPHTHALMIC BLOOD-PRESSURE MEASUREMENT IN THE HEMODYNAMIC EVALUATION OF OCCLUSIVE CAROTID-ARTERY DISEASE
    STRAUSS, AL
    RIEGER, H
    ROTH, FJ
    SCHOOP, W
    STROKE, 1989, 20 (08) : 1012 - 1015
  • [37] RELATIONSHIP BETWEEN OPHTHALMIC ARTERY BLOOD-FLOW AND RECANALIZATION OF OCCLUDED CAROTID-ARTERY - ULTRASONIC DOPPLER STUDY
    KANEDA, H
    IRINO, T
    ARITA, N
    MINAMI, T
    TANEDA, M
    SHIRAISHI, J
    STROKE, 1978, 9 (04) : 360 - 363
  • [38] Intraoperative blood flow measurement of the right gastroepiploic artery using pulsed Doppler echocardiography - Invited commentary
    He, GW
    ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 431 - 431
  • [39] Blood Flow Measurement System Using Ultrasound Doppler under Non-periodic Displacement of an Artery
    Ito, Keiichiro
    Asayama, Tomofumi
    Sugano, Shigeki
    Iwata, Hiroyasu
    2012 4TH IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2012, : 781 - 786
  • [40] Colour Doppler Imaging of Ophthalmic Artery and Central Retinal Artery in Glaucoma Patients with and without Diabetes Mellitus
    Srikanth, K.
    Kumar, M. Ashok
    Selvasundari, S.
    Prakash, M. L.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (04) : VC1 - VC2