Volumetric Blood Flow Measurement in the Ophthalmic Artery Using Colour Doppler

被引:6
|
作者
Katamay, R. [1 ]
Fleischlin, C. [1 ]
Gugleta, K. [1 ]
Flammer, J. [1 ]
Orguel, S. [1 ]
机构
[1] Univ Eye Clin, Basel, Switzerland
关键词
ophthalmic artery; volumetric blood flow; ultrasound; colour Doppler imaging; cardiac cycle; velocity; vessel diameter; cross-sectional area; PRESSURE MEASUREMENT; FINAPRES;
D O I
10.1055/s-0028-1109304
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Herewith we present a new method for measurement of the volumetric blood flow in absolute units in the ophthalmic artery. Patients and Methods: A Philips EnVisor HD ultrasound unit with a 12 - 3 MHz linear transducer was used to measure flow in the ophthalmic artery in 8 healthy young subjects. The transducer was mounted on a custom-made holder which enabled precise and reproducible positioning in 3 axes as well as in rotation angle. Blood flow velocity and vessel diameter were measured during 10 consecutive heartbeats. The measurements were ECG-gated. Blood vessel diameter and blood flow velocity were calculated in an average heartbeat cycle. Hence blood volume over time within a heartbeat cycle as well as blood flow in mL/min were determined. Simultaneously, cardiovascular parameters have been recorded by Finapres. Short time reproducibility (5 measurements on day 1) and long time reproducibility (5 days once daily) as well as interindividual coefficient of variation were evaluated. Results: Average blood flow in the ophthalmic artery in all measurements was 39.7 mL/min. The short-term intraindividual coefficient of variation was 24.1 +/- 9.2%, the long-term coefficient 32.0 +/- 13.8%. Interindividual coefficient of variation was 32.8%. Conclusions: Our method allows volumetric blood flow measurements in the ophthalmic artery in absolute units, reproducible to a limited extent.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [21] Age correlates with volumetric ophthalmic blood flow in humans
    Kagemann, L
    Orge, F
    Chung, HS
    Zalish, M
    Zarfati, D
    Kopecki, K
    Nowacki, EA
    Garzozi, H
    Arend, O
    Harris, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S549 - S549
  • [22] REPRODUCIBILITY OF OPHTHALMIC ARTERY BLOOD-FLOW ANALYSIS WITH TRANSCRANIAL DOPPLER FLOW SPECTRUM VS LINEAR COLOR DOPPLER IMAGING
    CHANG, EJ
    FANOUS, MM
    JOCSON, VL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1658 - 1658
  • [23] ESTIMATION OF BLOOD-FLOW IN THE CAROTID-ARTERY AND INTRAORBITAL OPHTHALMIC ARTERY BY COLOR PULSE DOPPLER ULTRASONOGRAPHY
    TANE, S
    HASHIMOTO, T
    ACTA OPHTHALMOLOGICA, 1992, 70 : 62 - 65
  • [24] Volumetric absolute blood flow measurement with fully connected vasculature network using Doppler optical coherence tomography
    Li, Ang
    Du, Congwu
    Pan, Yingtian
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIII, 2019, 10867
  • [25] BLOOD-FLOW VEROCITY OF THE OPHTHALMIC ARTERY IN DIABETIC-PATIENTS - A COLOR DOPPLER ANALYSIS
    AZUM, A
    INOUE, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S1001 - S1001
  • [26] VOLUMETRIC BLOOD-FLOW MEASUREMENT WITH COLOR DOPPLER ULTRASONOGRAPHY - THE IMPORTANCE OF VISUAL CLUES
    FILLINGER, MF
    SCHWARTZ, RA
    JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (03) : 123 - 130
  • [27] Direct assessment of volumetric blood flow from Doppler signal power using a Doppler flow wire system
    Mandinov, L
    Linka, A
    Lazar, L
    Jenni, R
    EUROPEAN HEART JOURNAL, 2000, 21 : 687 - 687
  • [28] Intravascular estimation of volumetric blood flow from Doppler powers using a Doppler guide wire
    Mandinov, L
    Linka, A
    Jenni, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 93A - 93A
  • [29] NONINVASIVE MEASUREMENT OF OPHTHALMIC ARTERY PRESSURE BY OPHTHALMOMANOMETRY-DOPPLER
    STRAUSS, AL
    KEDRA, AW
    LANCET, 1986, 2 (8511): : 870 - 870
  • [30] Validation of the first technique for non-invasive measurements of volumetric ophthalmic artery blood flow in humans
    Orge, F
    Kageman, L
    Chung, HS
    Zalish, M
    Zarfati, D
    Kopecki, K
    Nowacki, EA
    Arend, O
    Harris, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S387 - S387