Parameterization of a model-based 3D whole-body PET scatter correction

被引:0
|
作者
Wollenweber, SD [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parameterization of a fast implementation of the Ollinger model-based 3D scatter correction method [1] for PET has been evaluated using measured phantom data from a GE PET Advance TM. The Ollinger method explicitly estimates the 3D single-scatter distribution using measured emission and transmission data and then estimates the multiple-scatter as a convolution of the single-scatter. The main algorithm difference from that implemented by Ollinger is that the scatter correction does not explicity compute scatter for azimuthal angles; rather, it determines 2D scatter estimates for data within 2D "super-slices" using as input data from the 3D direct-plane (non-oblique) slices. These axial super-slice data are composed of data within a parameterized distance from the center of the super-slice. Such a model-based method can be parameterized, choice of which may significantly change the behavior of the algorithm. Parameters studied in this work included transaxial image downsampling, number of detectors to calculate scatter to, multiples kernel width and magnitude, number and thickness of super-slices and number of iterations. Measured phantom data included imaging of the NEMA NU-2001 image quality phantom, the IQ phantom with 2cm extra water-equivalent tissue strapped around its circumference and an attenuation phantom (20cm uniform cylinder with bone, water and air inserts) with two 8cm diameter water-filled non-radioactive arms placed by it's side. For the IQ phantom data, a subset of NEMA NU-2001 measures were used to determine the contrast-to-noise, lung residual bias and background variability. For the attenuation phantom, ROIs were drawn on the nonradioactive compartments and on the background. These ROIs were analyzed for inter and intra-slice variation, background bias and compartment-to-background ratio. Results: In most cases, the algorithm was most sensitive to multiple-scatter parameterization and least sensitive to transaxial downsampling. The algorithm showed convergence by the second iteration for the metrics used in this study. Also, the range of the magnitude of change in the metrics analyzed was small over all changes in parameterization. Further work to extend these results to other more realistic phantom and clinical datasets is warranted.
引用
收藏
页码:1471 / 1475
页数:5
相关论文
共 50 条
  • [21] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, Thomas
    Kinahan, Paul E.
    Townsend, David W.
    IEEE Transactions on Nuclear Science, 1997, 44 (6 pt 2): : 2400 - 2407
  • [22] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2400 - 2407
  • [23] Comparison of 2D and 3D qualitative whole body positron emission tomography (PET) without attenuation or scatter correction
    Kohlmyer, SG
    Mankoff, DA
    Lewellen, TK
    Kaplan, MS
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1367 - 1371
  • [24] Evaluation of scatter correction algorithms at the whole-body PET system ECAT exact HR+.
    Bellemann, ME
    RotaKops, E
    Brix, G
    Schmitz, T
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 844 - 844
  • [25] 3D Model-based partial volume correction for cardiac PET imaging in mice
    Dumouchel, Tyler
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [26] New, faster, image-based scatter correction for 3D PET
    Watson, CC
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1637 - 1641
  • [27] Efficient Point Clouds Based Scatter Correction for Fully 3D PET
    Gao, Fei
    Xu, Jingjia
    Liu, Huafeng
    Shi, Pengcheng
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2931 - 2934
  • [28] New, faster, image-based scatter correction for 3D PET
    Watson, CC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1587 - 1594
  • [29] A Registration Method Based on Contour Point Cloud for 3D Whole-Body PET and CT Images
    Song, Zhiying
    Jiang, Huiyan
    Yang, Qiyao
    Wang, Zhiguo
    Zhang, Guoxu
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [30] Correction: Clinical anthropometrics and body composition from 3D whole-body surface scans
    B. K. Ng
    B. J. Hinton
    B. Fan
    A. M. Kanaya
    J. A. Shepherd
    European Journal of Clinical Nutrition, 2021, 75 : 574 - 574