New, faster, image-based scatter correction for 3D PET

被引:0
|
作者
Watson, CC [1 ]
机构
[1] CTI PET Syst Inc, Knoxville, TN 37932 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on a new numerical implementation of the single-scatter simulation scatter correction algorithm for 3D PET. Its primary advantage over the original implementation is that it is a much faster calculation, currently requiring less than 30 sec execution time per bed position for an adult thorax, thus making clinical whole-body scatter correction more practical. The new code runs on a single processor workstation CPU instead of a vector processor array, making it highly portable. It is modular and independent of any particular reconstruction code. The computed scatter contribution is now intrinsically scaled relative to the emission image and no longer requires normalization to the scatter tails in the sinogram when all activity is contained within the field of view, making it more robust against noise. The new algorithm has been verified against the original code on both phantom and human thorax studies. Initial results indicate that scatter correction may be accurately performed following, instead of prior to, either 3D reprojection or Fourier rebinning. Some evidence is presented that the single-scatter operator, when applied to an uncorrected emission image provides reasonable compensation for multiple scatter.
引用
收藏
页码:1637 / 1641
页数:3
相关论文
共 50 条
  • [1] New, faster, image-based scatter correction for 3D PET
    Watson, CC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1587 - 1594
  • [2] 3D image-based scatter estimation and correction for multi-detector CT imaging
    Petersilka, M.
    Allmendinger, T.
    Stierstorfer, K.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] Statistical reconstruction-based scatter correction: a new method for 3D PET
    Zaidi, H
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 86 - 89
  • [4] Statistical model-based scatter correction for 3D PET
    Chiba, Y
    Kimura, Y
    Kitamura, K
    Oda, K
    Uchiyama, A
    Ishiwata, K
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 965 - 966
  • [5] Model-based scatter correction for fully 3D PET
    Ollinger, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 153 - 176
  • [6] A single scatter simulation technique for scatter correction in 3D pet
    Watson, CC
    Newport, D
    Casey, ME
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 255 - 268
  • [7] A comparative investigation of scatter correction in 3D PET
    Polycarpou, I.
    Marsden, P. K.
    Tsoumpas, C.
    INTERNATIONAL CONFERENCE ON IMAGE OPTIMISATION IN NUCLEAR MEDICINE (OPTINM), 2011, 317
  • [8] Advances in scatter correction for 3D PET/CT
    Watson, CC
    Casey, ME
    Michel, C
    Bendriem, B
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3008 - 3012
  • [9] Efficient Point Clouds Based Scatter Correction for Fully 3D PET
    Gao, Fei
    Xu, Jingjia
    Liu, Huafeng
    Shi, Pengcheng
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2931 - 2934
  • [10] AN INVESTIGATION OF PRACTICAL SCATTER CORRECTION TECHNIQUES FOR 3D PET
    TOWNSEND, DW
    CHOI, Y
    SASHIN, D
    MINTUN, MA
    GROOTOONK, S
    BAILEY, DL
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P50 - P50