Parameterization of a model-based 3D whole-body PET scatter correction

被引:0
|
作者
Wollenweber, SD [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parameterization of a fast implementation of the Ollinger model-based 3D scatter correction method [1] for PET has been evaluated using measured phantom data from a GE PET Advance TM. The Ollinger method explicitly estimates the 3D single-scatter distribution using measured emission and transmission data and then estimates the multiple-scatter as a convolution of the single-scatter. The main algorithm difference from that implemented by Ollinger is that the scatter correction does not explicity compute scatter for azimuthal angles; rather, it determines 2D scatter estimates for data within 2D "super-slices" using as input data from the 3D direct-plane (non-oblique) slices. These axial super-slice data are composed of data within a parameterized distance from the center of the super-slice. Such a model-based method can be parameterized, choice of which may significantly change the behavior of the algorithm. Parameters studied in this work included transaxial image downsampling, number of detectors to calculate scatter to, multiples kernel width and magnitude, number and thickness of super-slices and number of iterations. Measured phantom data included imaging of the NEMA NU-2001 image quality phantom, the IQ phantom with 2cm extra water-equivalent tissue strapped around its circumference and an attenuation phantom (20cm uniform cylinder with bone, water and air inserts) with two 8cm diameter water-filled non-radioactive arms placed by it's side. For the IQ phantom data, a subset of NEMA NU-2001 measures were used to determine the contrast-to-noise, lung residual bias and background variability. For the attenuation phantom, ROIs were drawn on the nonradioactive compartments and on the background. These ROIs were analyzed for inter and intra-slice variation, background bias and compartment-to-background ratio. Results: In most cases, the algorithm was most sensitive to multiple-scatter parameterization and least sensitive to transaxial downsampling. The algorithm showed convergence by the second iteration for the metrics used in this study. Also, the range of the magnitude of change in the metrics analyzed was small over all changes in parameterization. Further work to extend these results to other more realistic phantom and clinical datasets is warranted.
引用
收藏
页码:1471 / 1475
页数:5
相关论文
共 50 条
  • [1] Parameterization of a model-based 3-D PET scatter correction
    Wollenweber, SD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 722 - 727
  • [2] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    高飞
    Yamada Ryoko
    Watanabe Mitsuo
    刘华锋
    Chinese Physics B, 2009, 18 (07) : 3066 - 3072
  • [3] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    Gao Fei
    Ryoko, Yamada
    Mitsuo, Watanabe
    Liu Hua-Feng
    CHINESE PHYSICS B, 2009, 18 (07) : 3066 - 3072
  • [4] Model-based scatter correction for fully 3D PET
    Ollinger, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 153 - 176
  • [5] Statistical model-based scatter correction for 3D PET
    Chiba, Y
    Kimura, Y
    Kitamura, K
    Oda, K
    Uchiyama, A
    Ishiwata, K
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 965 - 966
  • [6] Attenuation and Scatter Correction for Whole-body PET Using 3D Generative Adversarial Networks
    Yang, Xiaofeng
    Lei, Yang
    Dong, Xue
    Wang, Tonghe
    Higgins, Kristin
    Liu, Tian
    Shim, Hyunsuk
    Curran, Walter
    Mao, Hui
    Nye, Jonathon
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [7] QUANTITATIVE FULLY 3D PET VIA MODEL-BASED SCATTER CORRECTION
    OLLINGER, JM
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P51 - P51
  • [8] Analysis of the parameterization of FORE-WLS reconstruction in 3D whole-body PET imaging
    Wollenweber, SD
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1486 - 1489
  • [9] High Accuracy Multiple Order Scatter Model for 3D Whole Body PET
    Markiewicz, P. J.
    Tamal, M.
    Julyan, P. J.
    Hastings, D. L.
    Reader, A. J.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2748 - 2752
  • [10] Clinical evaluation of single-photon attenuation correction for 3D whole-body PET
    Watson, CC
    Schaefer, A
    Luk, WK
    Kirsch, CM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1024 - 1031