When local impedance meets contact force: preliminary experience from the CHARISMA registry

被引:9
|
作者
Solimene, Francesco [1 ]
De Sanctis, Valerio [2 ]
Maggio, Ruggero [3 ]
Malacrida, Maurizio [4 ]
Segreti, Luca [5 ]
Anselmino, Matteo [6 ]
Schillaci, Vincenzo [1 ]
Mantica, Massimo [2 ]
Scaglione, Marco [7 ]
Dello Russo, Antonio [8 ]
Cauti, Filippo Maria [9 ]
Zingarini, Gianluca [10 ]
Pandozi, Claudio [11 ]
Cavaiani, Marco [4 ]
Ferraro, Anna [3 ]
Maglia, Giampiero [12 ]
Stabile, Giuseppe [1 ,13 ]
机构
[1] Clin Montevergine, Avellino, Mercogliano, Italy
[2] Ist Clin St Ambrogio, Dept Cardiac Electrophysiol & Pacing, Via Luigi Giuseppe Faravelli 16, I-20149 Milan, Italy
[3] Infermi Hosp, Rivoli, Italy
[4] Boston Sci, Milan, Italy
[5] Azienda Osped Univ Pisana, New Santa Chiara Hosp, Cardiac Thorac Vasc Dept, Div Cardiol 2, Pisa, Italy
[6] Univ Turin, Citta Salute & Sci Torino Hosp, Dept Med Sci, Div Cardiol, Turin, Italy
[7] Cardinal Massaia Hosp, Asti, Italy
[8] Marche Polytech Univ, Cardiol & Arrhythmol Clin, Ancona, Italy
[9] Osped San Giovanni Calibita, Fatebefratelli, Arrhythmol Unit, Rome, Italy
[10] Osped Santa Maria Misericordia, Perugia, Italy
[11] San Filippo Neri Hosp, Div Cardiol, Rome, Italy
[12] Azienda Osped Pugliese Ciaccio, Catanzaro, Italy
[13] Anthea Hosp, Bari, Italy
关键词
Atrial fibrillation; Catheter ablation; Local impedance; Contact force; Lesion formation; PVI; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION;
D O I
10.1007/s10840-022-01163-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have emerged as a viable real-time indicator of tissue characteristics and the consequent durability of the lesions created. We investigated the impact of catheter-tissue contact force (CF) on LI behavior during pulmonary vein isolation (PVI). Methods Forty-five consecutive patients of the CHARISMA registry undergoing de novo AF radiofrequency (RF) catheter ablation with a novel open-irrigated-tip catheter endowed with CF and LI measurement capabilities (Stablepoint (TM) catheter, Boston Scientific) were included. Results A total of 2895 point-by-point RF applications were analyzed (RF delivery time (DT) = 8.7 +/- 4s, CF = 13 +/-+/- 8 g, LI drop = 23 +/-+/- 7 Omega). All PVs were successfully isolated in an overall procedure time of 118 +/-+/- 34 min (fluoroscopy time = 13 +/-+/- 8 min). The magnitude of LI drop weakly correlated with CF (r = 0.13, 95% confidence interval (CI): 0.09 to 0.16, p < 0.0001), whereas both CF and LI drop inversely correlated with DT (r = -0.26, 95%CI: -0.29 to -0.22, p < 0.0001 for CF; r = -0.36, 95%CI: -0.39 to -0.33, p < 0.0001 for LI). For each 10 g of CF, LI drop markedly increased from 22.4 +/- 7 Omega to 24.0 +/- 8 Omega at 5 to 25 g CF intervals (5-14 g of CF vs 15-24 g of CF, p < 0.0001), whereas it showed smooth transition over 25 g (24.8 +/- 7 Omega at >= 25 g CF intervals, p = 0.0606 vs 15-24 g of CF). No major complications occurred during the procedures or within 30 days. Conclusions CF significantly affects LI drop and probable consequent lesion formation during RF PVI. The benefit of higher contact (> 25 g) between the catheter and the tissue appears to have less impact on LI drop.
引用
收藏
页码:749 / 758
页数:10
相关论文
共 50 条
  • [41] When Do Citizens Respond Politically to the Local Economy? Evidence from Registry Data on Local Housing Markets (vol 113, pg 499, 2019)
    Larsen, Martin Vinaes
    Hjorth, Frederik
    Dinesen, Peter Thisted
    Sonderskov, Kim Mannemar
    AMERICAN POLITICAL SCIENCE REVIEW, 2019, 113 (03) : 882 - 882
  • [42] NUTRIENT DEFICIENCIES AFTER LAPAROSCOPIC SLEEVE GASTROECTOMY, WHAT & WHEN: LOCAL EXPERIENCE FROM SAUDI ARABIA
    Almulhim, A. S.
    OBESITY SURGERY, 2014, 24 (08) : 1332 - 1333
  • [43] The role of local impedance drop in the acute lesion efficacy during pulmonary vein isolation performed with a new contact force sensing catheter-A pilot study
    Szegedi, Nandor
    Sallo, Zoltan
    Perge, Peter
    Piros, Katalin
    Nagy, Vivien Klaudia
    Osztheimer, Istvan
    Merkely, Bela
    Geller, Laszlo
    PLOS ONE, 2021, 16 (09):
  • [44] Characteristics and optimal ablation settings of a novel, contact-force sensing and local impedance-enabled catheter in an ex vivo perfused swine ventricle model
    Tsutsui, Kenta
    Kawano, Daisuke
    Mori, Hitoshi
    Kato, Ritsushi
    Ikeda, Yoshifumi
    Sumitomo, Naokata
    Fukaya, Hidehira
    Iwanaga, Shiro
    Nakano, Shintaro
    Muramatsu, Toshihiro
    Matsumoto, Kazuo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (12) : 3187 - 3194
  • [45] Catheter contact angle influences local impedance drop during radiofrequency catheter ablation: insight from a porcine experimental study
    Matsuura, G.
    Fukaya, H.
    Ogawa, E.
    Kawakami, S.
    Saito, D.
    Sato, T.
    Arakawa, Y.
    Kobayashi, S.
    Shirakawa, Y.
    Ishizue, N.
    Oikawa, J.
    Kishihara, J.
    Niwano, S.
    Ako, J.
    EUROPEAN HEART JOURNAL, 2021, 42 : 362 - 362
  • [46] PRELIMINARY EXPERIENCE FROM OUTPATIENT SUTURING IN LOCAL-ANESTHESIA OF FRESH LATERAL LIGAMENT RUPTURE IN TALOCRURAL JOINT
    BAR, BW
    TAUSCH, W
    ZENTRALBLATT FUR CHIRURGIE, 1988, 113 (19): : 1268 - 1272
  • [47] Fiber optic contact force catheter efficiency and effectiveness in paroxysmal AF ablation from a large, multi-national, prospective registry (ABLATOR)
    Verma, A.
    Albenque, J. P.
    Van Driel, V.
    Geller, C.
    Szili-Torok, T.
    Hansen, C.
    Miller, A.
    Hoffer, E.
    EUROPEAN HEART JOURNAL, 2018, 39 : 59 - 59
  • [48] Impact of cutaneous bioavailability in local skin toxicity: Preliminary results from cosmetics Europe skin bioavailability and metabolism task force
    Gregoire, Sebastien
    Cubberley, Richard
    Duplan, Helene
    Eilstein, Joan
    Ellison, Corie
    Hewitt, Nicky
    Jacques-Jamin, Carine
    Lange, Daniela
    Klaric, Martina
    Rothe, Helga
    Schepky, Andreas
    Roe, Amy
    TOXICOLOGY LETTERS, 2017, 280 : S44 - S44
  • [49] PRELIMINARY ASSESSMENT OF CANCER MORTALITY FOR PEOPLE WHO LIVE IN MUNICIPALITIES CLOSE TO AN INCINERATION PLANT USING DATA FROM THE LOCAL REGISTRY OF CAUSES OF DEATH
    d'Oro, Cavalieri L.
    Rognoni, M.
    Marchiol, L.
    Repossi, M.
    Merlo, E.
    Di Maggio, A.
    EPIDEMIOLOGIA & PREVENZIONE, 2010, 34 (5-6): : 136 - 136
  • [50] Transcatheter aortic valve implantation (TAVI) by centres with and without an on-site cardiac surgery programme: preliminary experience from the German TAVI registry
    Eggebrecht, Holger
    Mehta, Rajendra H.
    Haude, Michael
    Sack, Stefan
    Mudra, Harald
    Hein, Ralph
    Brachmann, Johannes
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Zahn, Ralf
    Sechtem, Udo
    Richardt, Gert
    Schneider, Steffen
    Senges, Jochen
    EUROINTERVENTION, 2014, 10 (05) : 602 - 608