Temperature measurement using NIR camera with automatic adjustment of integration time for monitoring high-temperature industrial processes

被引:3
|
作者
Wiecek, Piotr [1 ]
Zgraja, Jerzy [1 ]
Sankowski, Dominik [1 ]
机构
[1] Lodz Univ Technol, Inst Appl Comp Sci, Lodz, Poland
关键词
NIR camera; high-temperature industrial processes; calibrated temperature measurement; EMISSIVITY;
D O I
10.1080/17686733.2017.1401835
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The system presented in this paper is based on a Near Infrared Radiation (NIR) camera to measure temperature above 300 degrees C. The CCD camera selected absorbs a small portion of radiation in the near infrared range, above =700nm. In addition, by using an NIR filter one can cut off the visible light to reduce noise and unwanted radiation. The system has been developed at the Institute of Applied Computer Science, Lodz University of Technology. This system has been made for controlling industrial thermal processes during the inductive heating hardening. The varying of camera integration time has been applied to avoid the saturation and to increase the sensitivity at low temperature. The emissivity of the inductive heating object has been taken into account. New algorithms for temperature calibration and image processing have been developed enabling measurement of temperatures from 300 degrees C, thanks to the application of automatic adjustment of integration time.
引用
收藏
页码:132 / 144
页数:13
相关论文
共 50 条
  • [21] Flexible operation and integration of high-temperature heat pumps using large temperature glides
    Knorr, Lukas
    Schlosser, Florian
    Horstmann, Nils
    Divkovic, Denis
    Meschede, Henning
    APPLIED ENERGY, 2024, 368
  • [22] The thermodynamic potential of high-temperature transcritical heat pump cycles for industrial processes with large temperature glides
    Vieren, Elias
    Demeester, Toon
    Beyne, Wim
    Arteconi, Alessia
    De Paepe, Michel
    Lecompte, Steven
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [23] A new concept composite heat exchanger to be applied in high-temperature industrial processes
    Luzzatto, C
    Morgana, A
    Chaudourne, S
    ODoherty, T
    Sorbie, G
    APPLIED THERMAL ENGINEERING, 1997, 17 (8-10) : 789 - 797
  • [24] Real-time Monitoring of Internal Temperature and Voltage of High-temperature Fuel Cell Stack
    Lee, Chi-Yuan
    Weng, Fang-Bor
    Huang, Yen-Pu
    Chang, Chih-Ping
    Cheng, Chih-Kai
    ELECTROCHIMICA ACTA, 2015, 161 : 413 - 419
  • [25] Heat transfer error analysis of high-temperature wall temperature measurement using thermocouple
    Kou, Zhihai
    Wu, Rongxiang
    Wang, Qingyin
    Li, Binbin
    Li, Congzheng
    Yin, Xunyan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
  • [26] HIGH-TEMPERATURE DOPPLER MEASUREMENT USING PULSED ACTIVATION TECHNIQUE
    BHATTACHARYYA, SK
    FOELL, WK
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 461 - 462
  • [27] A Real-Time 3D Measurement System for the Blast Furnace Burden Surface Using High-Temperature Industrial Endoscope
    Xu, Tianxiang
    Chen, Zhipeng
    Jiang, Zhaohui
    Huang, Jiancai
    Gui, Weihua
    SENSORS, 2020, 20 (03)
  • [28] In situ spectroscopic ellipsometry in vertical furnace: monitoring and control of high-temperature processes
    Petrik, P
    Schneider, C
    VACUUM, 2001, 61 (2-4) : 427 - 434
  • [29] Automatic Modeling of High-Temperature Superconducting Cable Using Reinforcement Learning
    Bang, Su Sik
    Kwon, Gu-Young
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [30] Real-Time Measurement System for High-Temperature Drop Calorimeter
    Kratmueller, Martin
    CYBERNETICS AND INFORMATION TECHNOLOGIES, 2010, 10 (01) : 64 - 71