Temperature measurement using NIR camera with automatic adjustment of integration time for monitoring high-temperature industrial processes

被引:3
|
作者
Wiecek, Piotr [1 ]
Zgraja, Jerzy [1 ]
Sankowski, Dominik [1 ]
机构
[1] Lodz Univ Technol, Inst Appl Comp Sci, Lodz, Poland
关键词
NIR camera; high-temperature industrial processes; calibrated temperature measurement; EMISSIVITY;
D O I
10.1080/17686733.2017.1401835
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The system presented in this paper is based on a Near Infrared Radiation (NIR) camera to measure temperature above 300 degrees C. The CCD camera selected absorbs a small portion of radiation in the near infrared range, above =700nm. In addition, by using an NIR filter one can cut off the visible light to reduce noise and unwanted radiation. The system has been developed at the Institute of Applied Computer Science, Lodz University of Technology. This system has been made for controlling industrial thermal processes during the inductive heating hardening. The varying of camera integration time has been applied to avoid the saturation and to increase the sensitivity at low temperature. The emissivity of the inductive heating object has been taken into account. New algorithms for temperature calibration and image processing have been developed enabling measurement of temperatures from 300 degrees C, thanks to the application of automatic adjustment of integration time.
引用
收藏
页码:132 / 144
页数:13
相关论文
共 50 条
  • [11] AUTOMATIC-MEASUREMENT OF ELECTRICAL ENERGY IN HIGH-TEMPERATURE CALORIMETERS
    FLEISHER, LL
    STOLYAROVA, TA
    MEASUREMENT TECHNIQUES, 1978, 21 (03) : 399 - 401
  • [12] AUTOMATIC BALANCE FOR HIGH-TEMPERATURE MEASUREMENT OF MAGNETIC SUSCEPTIBILITY.
    Konovalov, S.V.
    Singer, V.V.
    Radovskii, I.Z.
    Klepinin, V.A.
    Instruments and experimental techniques New York, 1987, 30 (3 pt 2): : 678 - 682
  • [13] USING MICROWAVE TECHNIQUES FOR HIGH-TEMPERATURE MEASUREMENT
    BILLETER, TR
    INSTRUMENTS & CONTROL SYSTEMS, 1972, 45 (02): : 107 - &
  • [14] Temperature measurement by IR camera of heated device to high temperature during a short time
    Sonneck-Museux, Nathanaelle
    Verge, Philippe
    Judic, Jean-Pierre
    Edard, Pierrick
    TWELFTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2015, 9534
  • [15] PEAK-TEMPERATURE MEASUREMENT FOR SELF-PROPAGATING HIGH-TEMPERATURE SYNTHESIS PROCESSES
    MASLOV, VM
    BOROVINSKAYA, IP
    MERZHANOV, AG
    COMBUSTION EXPLOSION AND SHOCK WAVES, 1978, 14 (05) : 618 - 623
  • [16] High-Temperature Ceramic Heating Elements to Optimize Industrial Manufacturing Processes
    Kuehl, Hannes
    CFI-CERAMIC FORUM INTERNATIONAL, 2010, 87 (04): : E36 - E37
  • [17] CHEMICAL-ENGINEERING - KEY FOR COMPREHENSION OF INDUSTRIAL HIGH-TEMPERATURE PROCESSES
    LANGE, KW
    ARCHIV FUR DAS EISENHUTTENWESEN, 1972, 43 (02): : 93 - &
  • [18] A STUDY OF HIGH-TEMPERATURE DAMAGE PROCESSES USING MICRORADIOGRAPHY
    BENCI, JE
    POPE, DP
    NONDESTRUCTIVE MONITORING OF MATERIALS PROPERTIES, 1989, 142 : 195 - 200
  • [19] Radio-telemetric high-temperature monitoring in industrial heat treatment
    Konitzer, Carola
    Göbel, Martin
    Gaswaerme International, 2004, 53 (04): : 206 - 208
  • [20] Electrostatic probe measurement in an industrial furnace for high-temperature air conditions
    Yokomori, Takeshi
    Mochida, Susumu
    Araake, Tadahiro
    Maruta, Kaoru